DLA DSCC-DWG-84133 REV E-2008 RELAYS ELECTROMAGNETIC PERMANENT MAGNET DRIVE 2PDT LOW LEVEL TO 5 AMPERES (SIMILAR TO MIL-R-6106 27 EXCEPT FOR 12 V DC COIL AND INVERTED STUD MOUNT)《永.pdf
《DLA DSCC-DWG-84133 REV E-2008 RELAYS ELECTROMAGNETIC PERMANENT MAGNET DRIVE 2PDT LOW LEVEL TO 5 AMPERES (SIMILAR TO MIL-R-6106 27 EXCEPT FOR 12 V DC COIL AND INVERTED STUD MOUNT)《永.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-84133 REV E-2008 RELAYS ELECTROMAGNETIC PERMANENT MAGNET DRIVE 2PDT LOW LEVEL TO 5 AMPERES (SIMILAR TO MIL-R-6106 27 EXCEPT FOR 12 V DC COIL AND INVERTED STUD MOUNT)《永.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE APPROVED A Title clarification and part number correction. 28 Mar 85 S. Searcy B Changed manufacturers eligibility. 26 Feb 87 S. Searcy C Changes in accordance with NOR 5945-R005. 02 Mar 00 K. Cottongim D Validation and update. 17 Sep 03 K. Cottongim E Incorporated bo
2、ilerplate updates. 18 Sep 08 Michael A. Radecki Prepared in accordance with ASME Y14.100 Source control drawingREV E E E E E E E REV STATUS OF PAGES PAGES 1 2 3 4 5 6 7 PMIC N/A PREPARED BY Richard A. Yannitti DESIGN ACTIVITY DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OH 45444-5000 CHECKED BY Max E.
3、Lewis APPROVED BY Steven Searcy TITLE RELAYS, ELECTROMAGNETIC, PERMANENT MAGNET DRIVE, 2PDT, LOW LEVEL TO 5 AMPERES (SIMILAR TO MIL-R-6106/27 EXCEPT FOR 12 V DC COIL AND INVERTED STUD MOUNT) SIZE A CODE IDENT. NO. 14933 DWG NO. 84133 Original date of drawing 28 September 1984 REV E PAGE 1 OF 7 AMSC
4、N/A 5945-E133 CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT N
5、O. 14933 DWG NO. 84133 REV E PAGE 2 1. SCOPE 1.1 Scope. This drawing describes the requirements for a hermetically sealed electromechanical relay supplied to the requirements of an established reliability version of MIL-PRF-83536/1 (see 6.5), except as noted herein. 1.2 Part or Identifying Number (P
6、IN). The complete PIN shall be as follows: 84133 -001 | | | | Drawing Dash number number 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specific
7、ation or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents in sections 3 and 4 of this specification, whether or not they are listed
8、. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. D
9、EPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-83536 - Relays, Electromagnetic, Established Reliability, General Specification For. MIL-PRF-83536/1 - Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 5 Amperes, Permanent Magnetic Drive, Hermetically Sealed, All Welded, DC Coils. DEPA
10、RTMENT OF DEFENSE STANDARDS MIL-STD-202 - Electronic and Electrical Component Parts. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia,
11、 PA 19111-5094.) 2.3 Order of precedence. Unless otherwise noted herein, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a sp
12、ecific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-83536, MIL-PRF-83536/1, and as specified herein. 3.2 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-P
13、RF-83536, MIL-PRF-83536/1, and herein (see figure 1). 3.2.1 Design documentation. Unless otherwise specified in the contract or purchase order, the design documentation shall be in accordance with MIL-PRF-83536, and shall be retained by the manufacturer and available for review by the acquiring acti
14、vity or contractor upon request. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 84133 REV E PAGE 3 3.3 Electrical characteristics. Relays shall meet all electrical ch
15、aracteristics as specified in MIL-PRF-83536/1 and herein. 3.3.1 Coil data and operational data. See table I. 3.3.2 Contact data and load rating. See MIL-PRF-83536/1. 3.3.3 Operate time. 4 milliseconds maximum with rated coil voltage at 25C. 3.3.4 Release time. 4 milliseconds maximum from rated coil
16、voltage at 25C. 3.3.5 Contact bounce. 1 millisecond maximum. 3.3.6 Overload current. 20 amperes dc, 30 amperes ac. 3.3.7 Rupture current. 25 amperes dc, 40 amperes ac. 3.4 Physical. Physical requirements of the relay shall be as specified in MIL-PRF-83536/1 and herein. 3.4.1 Mounting studs. The moun
17、ting studs shall be corrosion resistant steel. 3.4.2 Dimension and configuration. See figure 1. TABLE I. Operating characteristics. Coil data At 25 C Over temperature range Maximum pickup voltage Coil voltage (V dc) 1/ Rated Max Coil resistance (ohms) minimum Specified pickup voltage (V dc) 2/ Speci
18、fied hold voltage (V dc) 2/ Specified dropout voltage (V dc) 2/ Specified pickup voltage (V dc) 2/ Specified hold voltage (V dc) 2/ Specified dropout voltage (V dc) 2/ High temperature test Continuous current test 12 14.5 85 6.5 3.3 0.75 9.0 4.5 0.5 9.9 11.25 1/ CAUTION: The use of any coil voltages
19、 less than the rated coil voltage will compromise the operation of the relay. 2/ Pickup, hold, and dropout voltages as shown are for test purposes only and are not to be used for design criteria. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENS
20、E ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 84133 REV E PAGE 4 FIGURE 1. Outline drawing (for details, see table I). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE
21、A CODE IDENT NO. 14933 DWG NO. 84133 REV E PAGE 5 Inches mm .001 .002 .032 .040 .065 .112 .210 .224 .375 .410 .500 .640 .810 0.03 0.05 0.81 1.02 1.65 2.84 5.33 5.69 9.53 10.41 12.70 16.26 20.57 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unles
22、s otherwise specified, tolerance is .010 (0.25 mm). 4. There shall be affixed to the relay a suitable legible circuit diagram that identifies each terminal location specified. 5. These relays are polarized monostable. 6. This relay shall not operate or be damaged by reverse polarity. Semiconductors
23、shall not be used for this purpose. 7. Permanent magnet drive consists of a permanent magnet with its flux path switched and combined with the electro-magnet flux. 8. Metric equivalents are given for general information only. FIGURE 1. Outline drawing (for details, see table I) - Continued. Provided
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG84133REVE2008RELAYSELECTROMAGNETICPERMANENTMAGNETDRIVE2PDTLOWLEVELTO5AMPERESSIMILARTOMILR610627EXCEPTFOR12VDCCOILANDINVERTEDSTUDMOUNT

链接地址:http://www.mydoc123.com/p-688770.html