DLA DSCC-DWG-84110 REV D-2013 TRANSFORMER POWER MINIATURE 115 V OR 26 V 400 HZ.pdf
《DLA DSCC-DWG-84110 REV D-2013 TRANSFORMER POWER MINIATURE 115 V OR 26 V 400 HZ.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-84110 REV D-2013 TRANSFORMER POWER MINIATURE 115 V OR 26 V 400 HZ.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE APPROVED A Page 2, 1.1 Editorial correction. Page 4, figure 1, changed .75 to .76 in three places. Page 5, 3.3.5, add “Hz”. Page 5, 3.4.3, add alternate polymeric material. Page 5, 3.4.4 revised. Page 8, table I, change 70.0 to 70.4. Pages 10, 11, 12, 13, 14,15, and 1
2、6; change FSCM 95086 to 90095. 27 January 1986 Ivan R. Jones B Page 2, 3.3.1 and 3.3.3 revised. Page 3, change .020 to .020 +.010 -.005. Page 5, 3.4.4, remove 1.020. Pages 7, 8, and 9; revise sec. current and VA rating headings. Pages 10 and 11; correct misc. model nos. 22 July 1988 Randy Larson C C
3、hanges in accordance with NOR 5950-R007-002. 23 September 2002 Kendall Cottongim D Addition of pure tin prohibition requirement. Update drawing format throughout. Removal of an Approved source of supply. 5 September 2013 Michael Radecki REV STATUS OF PAGES REV D D D D D D D D D D D D D D D D PAGES 1
4、 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PMIC N/A PREPARED BY D.E. MorganDEFENSE ELECTRONIC SUPPLY CENTER DAYTON, OHIO Original date of drawing 23 August 1984 CHECKED BY D. E. Morgan TITLE TRANSFORMER, POWER, MINIATURE 115V OR 26 V, 400 Hz APPROVED BY Randy LarsonSIZE A CODE IDENT. NO. 037Z3 DWG NO. 84
5、110 SCALE N/A REV D PAGE 1 OF 16 AMSC N/A 5950-2013-E05 CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS CHANGED NAMES TO: DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 INACTIVE FOR NEW DESIGN AFTER 23 September 2002. FOR REPLACEMENT PURPOSES ONLY. Provided by IHSNot for ResaleNo reproduction or networ
6、king permitted without license from IHS-,-,-DEFENSE ELECTRONIC SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 84110 REV D PAGE 2 1. SCOPE 1.1 Scope. This drawing describes the requirements for 400 Hz miniature power transformer. This drawing provides for a level of transformer qualit
7、y and reliability assurance for power transformer in accordance with MIL-PRF-27. 1.2 Part or Identifying Number (PIN). The complete PIN shall be as follows: 84110 -01 | | Drawing Dash number number 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3
8、and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all
9、specified requirements of documents in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein.
10、 Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-27 - Transformers and Inductors (Audio, Power, and High-Power Pulse), General Specification For. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test
11、 Methods for Electronic and Electrical Component Parts. MIL-STD-1276 - Leads for Electronic Component Parts. (Copies of these documents are available online at http:/quicksearch.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.
12、4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a sp
13、ecific exemption has been obtained. 3. REQUIREMENTS 3.1 Interface and physical dimensions. 3.1.1 Item Requirements. The individual item requirements shall be in accordance with MIL-PRF-27, and as specified herein. 3.2 Design, construction, and physical dimensions. The design, construction, and physi
14、cal dimensions shall be as specified for A grade 5 transformer in accordance with MIL-PRF-27, and as specified herein. 3.2.1 Design documentation. The design documentation shall be in accordance with MIL-PRF-27. Unless otherwise specified in the contract or purchase order, documentation shall be ret
15、ained by the manufacturer and available for review by the acquiring activity or contractor upon request. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONIC SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 84110 REV D PAG
16、E 3 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are for general information only. 3. See table I for VA ratings. 4. Marking shall be on the side of the case. 5. Primary and secondary electrical values, specified in table I, shall be marked as applicable. 6. Dots on circuit diagram indi
17、cate polarity. Figure 1. Dimensions and configuration. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONIC SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 84110 REV D PAGE 4 VA rating A (dia) Max B (dia) C (dia) D (dia)
18、Weight (grams) max .375 .750 1.020 1.690 2.400 .51 .51 .76 .76 .76 .35 .01 .35 .01 .60 .01 .60 .01 .60 .01 .218 .010 .218 .010 .475 .010 .475 .010 .475 .010 .350 .500 .375 .520 .820 7 10.5 16.8 23.8 40.0 Figure 1. Dimensions and configuration Continued. 3.3 Electrical ratings. 3.3.1 Regulation. Regu
19、lation = Shall not exceed 17 percent for units with VA rating of 2.4 and 34 percent for all other units. 3.3.2 Primary voltage. Primary voltage shall be either 115V or 26V. 3.3.3 Secondary voltage. With proper voltage (115 V or 26 V) applied to the primary and the secondary current adjusted to one-h
20、alf of the maximum current specified in table I, the secondary voltage shall be as specified in table I 5 percent for units with VA rating of .375 and .750, and 3 percent for all other units. 3.3.4 Secondary current. See table I. 3.3.5 Frequency. The frequency shall be 400 Hz 20 Hz at 115 V and 26 V
21、 primary voltages. 3.3.6 Polarity. Polarity shall be in accordance with the circuit diagram in figure 1. 3.4. Design and construction. 3.4.1 Dimensions and configuration: Dimensions and configuration shall be as specified on figure 1 and in table I. 3.4.2 Weight. The weight shall be as specified on
22、figure 1. 3.4.3 Case. The case shall be metal or polymeric material. 3.4.4 Terminals. The terminals shall be copper clad steel or one-half hard copper, per MIL-STD-1276. Units with VA ratings of 1.690 and 2.400 shall have a diameter of .020 .001 inch. All others shall have a diameter of .016 .001 in
23、ch. 3.4.5 Operating temperature range. The operating temperature range shall be -55C to +130C. 3.4.6 Temperature rise. The maximum temperature rise shall be +40C at a maximum ambient temperature of +90C. 3.5 Terminal strength. The terminal strength shall be in accordance with MIL-STD-202, method 211
24、, test condition A, 2 pounds applied force. Sec. Voltage (no load) Sec. Voltage (max current) X 100 Sec. Voltage (max current) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONIC SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 D
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG84110REVD2013TRANSFORMERPOWERMINIATURE115VOR26V400HZPDF

链接地址:http://www.mydoc123.com/p-688768.html