ASTM E3020-2015 Standard Practice for Ignition Sources《点火源的标准实施规程》.pdf
《ASTM E3020-2015 Standard Practice for Ignition Sources《点火源的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E3020-2015 Standard Practice for Ignition Sources《点火源的标准实施规程》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3020 15Standard Practice forIgnition Sources1This standard is issued under the fixed designation E3020; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the
2、year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes a series of ignition sources thathave been used and that are potentially applicable to assessingfire-test-response characteristics resulting from t
3、he ignition ofmaterials, products, or assemblies.1.2 This practice does not identify which of the ignitionsources described is applicable to any specific use since that isa function of the associated fire hazard (see also 5.2).1.3 This practice is not necessarily comprehensive and it ispossible that
4、 other applicable ignition sources exist (see also5.3).1.4 This practice describes both flaming and non-flamingignition sources, since the outcome of a non-flaming ignitioncan be the eventual flaming ignition of these materials orproducts (see also 4.2).1.5 This practice does not provide pass/fail c
5、riteria that canbe used as a regulatory tool.1.6 This fire standard cannot be used to provide quantitativemeasures.1.7 Fire testing is inherently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.1.8 This standard is used to measure and describe th
6、eresponse of materials, products, or assemblies to heat and flameunder controlled conditions, but does not by itself incorporateall factors required for fire hazard or fire risk assessment of thematerials, products, or assemblies under actual fire conditions.1.9 This practice contains notes and foot
7、notes which pro-vide explanatory material. These notes and footnotes (exclud-ing those in tables and figures) shall not be consideredrequirements of the standard.1.10 The values stated in SI units are to be regarded asstandard in referee decisions. No other units of measurementare included in this s
8、tandard. See IEEE/ASTM SI 10 for furtherdetails.1.11 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of re
9、gulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D635 Test Method for Rate of Burning and/or Extent andTime of Burning of Plastics in a Horizontal PositionD1929 Test Method for Determining Ignition Temperatureof PlasticsD3874 Test Method for Ignition of Materials by Hot W
10、ireSourcesD5025 Specification for Laboratory Burner Used for Small-Scale Burning Tests on Plastic MaterialsD5207 Practice for Confirmation of 20mm (50W) and125mm (500W) Test Flames for Small-Scale BurningTests on Plastic MaterialsD5424 Test Method for Smoke Obscuration of InsulatingMaterials Contain
11、ed in Electrical or Optical Fiber CablesWhen Burning in a Vertical Cable Tray ConfigurationD5537 Test Method for Heat Release, Flame Spread, SmokeObscuration, and Mass Loss Testing of Insulating Mate-rials Contained in Electrical or Optical Fiber Cables WhenBurning in a Vertical Cable Tray Configura
12、tionD6194 Test Method for Glow-Wire Ignition of MaterialsE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE136 Test Method for Behavior of Materials in a VerticalTube Furnace at 750CE176 Terminology of Fire StandardsE662 Test Method for Specific Optical Density of SmokeGenerat
13、ed by Solid MaterialsE906/E906M Test Method for Heat and Visible SmokeRelease Rates for Materials and Products Using a Ther-mopile MethodE1321 Test Method for Determining Material Ignition andFlame Spread Properties1This practice is under the jurisdiction of ASTM Committee E05 on FireStandards and i
14、s the direct responsibility of Subcommittee E05.33 on Fire SafetyEngineering.Current edition approved Aug. 1, 2015. Published September 2015. DOI:10.1520/E3020152For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book o
15、f ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E1352 Test Method for Cigarette Ignition Resistance ofMock-Up Upholstered Furniture As
16、sembliesE1353 Test Methods for Cigarette Ignition Resistance ofComponents of Upholstered FurnitureE1354 Test Method for Heat and Visible Smoke ReleaseRates for Materials and Products Using an Oxygen Con-sumption CalorimeterE1537 Test Method for Fire Testing of Upholstered Furni-tureE1590 Test Method
17、 for Fire Testing of MattressesE1822 Test Method for Fire Testing of Stacked ChairsE1995 Test Method for Measurement of Smoke ObscurationUsing a Conical Radiant Source in a Single ClosedChamber, With the Test Specimen Oriented HorizontallyE2058 Test Methods for Measurement of Material Flamma-bility
18、Using a Fire Propagation Apparatus (FPA)E2187 Test Method for Measuring the Ignition Strength ofCigarettesE2574/E2574M Test Method for Fire Testing of School BusSeat AssembliesIEEE/ASTM SI 10 American National Standard for Use ofthe International System of Units (SI): The Modern MetricSystem2.2 Inst
19、itute of Electrical and Electronic Engineers (IEEE)Standards:3IEEE 383 IEEE Standard for Qualifying Class 1E ElectricCables and Field Splices for Nuclear Power GeneratingStationsIEEE 1202 IEEE Standard for Flame Testing of Cables forUse in Cable Tray in Industrial and Commercial Occu-pancies2.3 Inte
20、rnational Organization for Standardization (ISO)Standards:4ISO 871 PlasticsDetermination of Ignition TemperatureUsing a Hot-Air FurnaceISO 5657 Reaction to Fire TestsIgnitability of BuildingProducts Using a Radiant Heat SourceISO 5659-2 PlasticsSmoke Generation Part 2: Determina-tion of Optical Dens
21、ity by a Single-Chamber TestISO 5660-1 Reaction to Fire TestsHeat Release, SmokeProduction and Mass Loss RatePart 1: Heat Release(Cone Calorimeter Method)ISO 8191-1 FurnitureAssessment of the Ignitability ofUpholstered FurniturePart 1: Ignition Source: Smoul-dering CigaretteISO 8191-2 FurnitureAsses
22、sment of the Ignitability ofUpholstered FurniturePart 2: Ignition Source: MatchFlame EquivalentISO 9705 Reaction to Fire TestsFull-Scale Room Test forSurface ProductsISO 12863 Standard Test Method for Assessing the IgnitionPropensity of CigarettesISO 12949 Standard Test Method for Measuring the Heat
23、Release Rate of Low Flammability Mattresses and Mat-tress SetsISO 13943 Fire SafetyVocabulary2.4 International Electrotechnical Commission (IEC) Stan-dards:5IEC 60332-1-2 Tests on Electric and Optical Fibre CablesUnder Fire ConditionsPart 1-2: Test for Vertical FlamePropagation for a Single Insulate
24、d Wire or CableProcedure for 1 kW Pre-mixed FlameIEC 60332-2-1 Tests on Electric and Optical Fibre CablesUnder Fire ConditionsPart 2-1: Test for Vertical FlamePropagation for a Single Small Insulated Wire or Cable ApparatusIEC 60332-3-10 Tests on Electric and Optical Fibre CablesUnder Fire Condition
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME30202015STANDARDPRACTICEFORIGNITIONSOURCES 火源 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-532247.html