ASTM D5952-2002 Standard Guide for Inspecting Water Systems for Legionellae and Investigating Possible Outbreaks of Legionellosis (Legionnaires Disease or Pontiac Fever)《军用住处的可中断调查.pdf
《ASTM D5952-2002 Standard Guide for Inspecting Water Systems for Legionellae and Investigating Possible Outbreaks of Legionellosis (Legionnaires Disease or Pontiac Fever)《军用住处的可中断调查.pdf》由会员分享,可在线阅读,更多相关《ASTM D5952-2002 Standard Guide for Inspecting Water Systems for Legionellae and Investigating Possible Outbreaks of Legionellosis (Legionnaires Disease or Pontiac Fever)《军用住处的可中断调查.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5952 02Standard Guide forInspecting Water Systems for Legionellae and InvestigatingPossible Outbreaks of Legionellosis (Legionnaires Diseaseor Pontiac Fever)1This standard is issued under the fixed designation D 5952; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers appropriate responses for employers,b
3、uilding owners and operators, facility managers, health andsafety professionals, public health authorities, and others: (1)toa concern that a water system may be contaminated with thebacteria known as legionellae (see 6.1); and (2) to the identi-fication of one or more cases of Legionnaires disease
4、orPontiac fever (see 6.3-6.5). Comprehensive and explicit rec-ommendations to limit legionella multiplication in water sys-tems and to disinfect potential sources of human exposure tolegionellae are beyond this guides scope.1.2 This standard does not purport to address all of thesafety concerns, if
5、any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 7.3 and 8.5 forspecific hazard statements.2. Referenced Documents2.1 ASTM Standards:2D
6、 512 Test Methods for Chloride Ion in WaterD 596 Practice for Reporting Results of Analysis of WaterD 887 Practices for Sampling Water-Formed DepositsD 1067 Test Methods for Acidity or Alkalinity of WaterD 1129 Terminology Relating to WaterD 1192 Specification for Equipment for Sampling Waterand Ste
7、am in Closed ConduitsD 1293 Test Methods for pH of WaterD 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 2331 Practices for Preparation and Preliminary Testing ofWater-Formed DepositsD 3370 Practices for Sampling Water from Closed ConduitsD 3856 Guide for Good Laboratory Practices
8、 in Laborato-ries Engaged in Sampling and Analysis of WaterD 4840 Guide for Sample Chain-of-Custody ProceduresE 645 Test Method for Efficacy of Microbicides Used inCooling Systems2.2 APHA Documents:3The Public Health Law Manual, Second EditionStandard Methods for the Examination of Water and Waste-w
9、ater, Twentieth EditionControl of Communicable Diseases Manual, SeventeenthEdition2.3 ASHRAE Documents:4Cooling Towers. HandbookHeating, Ventilating, and Air-Conditioning Systems and EquipmentCodes and Standards. HandbookHeating, Ventilating, andAir-Conditioning Systems and EquipmentWater Treatment.
10、 HandbookHeating, Ventilating, and Air-Conditioning Systems and EquipmentMinimizing the Risk of LegionellosisAssociated with Build-ing Water Systems2.4 ASM Documents:Manual of Clinical Microbiology, Fifth Edition5Manual of Environmental Microbiology62.5 CDC Documents:7Guidelines for Prevention of No
11、socomial PneumoniaHospital-Laboratory Diagnosis of Legionella Infections1This guide is under the jurisdiction ofASTM Committee D22 on Sampling andAnalysis of Atmospheres and is the direct responsibility of Subcommittee D22.05on Indoor Air.Current edition approved November 10, 2002. Published January
12、 2003. Origi-nally approved in 1996. Last previous edition approved in 1996 as D 5952 - 96(02).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Documen
13、t Summary page onthe ASTM website.3Available from the American Public Health Association, 1015 18th St. N.W.,Washington, DC 20036, USA, 1990, 1989.4Available from the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329, USA.5Winn
14、, W.C., “Legionella,” in Manual of Clinical Microbiology, Murray, P.R.,Ed., American Society for Microbiology, Washington, DC 20005, USA, 1999, pp.572585.6Fields, B. S. Legionellae and Legionnaires disease in Manual of Environmen-tal Microbiology. Hurst, C.J., Ed.,American Society for Microbiology,
15、Washington,DC 20005, USA, 1997, pp. 666675.7Available from the U.S. Department of Health and Human Services, PublicHealth Service, Centers for Disease Control and Prevention, Atlanta, GA 30333,USA, 1987, 1994, 1996, 1997, 2000.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
16、onshohocken, PA 19428-2959, United States.Procedures for the Recovery of Legionella from the Envi-ronmentFinal Recommendations to Minimize Transmission of Le-gionnaires Disease from Whirlpool Spas on CruiseShipsCase Definitions for Infectious Conditions Under PublicHealth SurveillanceGuidelines for
17、Preventing Opportunistic Infections AmongHematopoietic Stem Cell Transplant RecipientsOccupational Safety and Health Administration TechnicalManual, Section II - Chapter 7, Legionnaires Disease2.6 State of Maryland Documents:8Report of the Maryland Scientific Working Group to StudyLegionella in Wate
18、r Systems in Healthcare Institutions3. Terminology3.1 Definitions from Compilation of ASTM Standard Defi-nitions.3.1.1 air conditioning, nthe simultaneous control of all,or at least the first three, of those factors affecting both thephysical and chemical conditions of the atmosphere within anystruc
19、ture. These factors include temperature, humidity, motion,distribution, dust, bacteria, odor, and toxic gases.3.1.2 monitoring, nthe continual sampling, measuring,recording, or signaling, or both, of the characteristics of wateror waterborne material.3.1.3 pH, nthe negative logarithm of hydrogen-ion
20、 activ-ity in aqueous solution or the logarithm of the reciprocal of thehydrogen-ion activity.3.1.4 sampling, nobtaining a representative portion of thematerial concerned.3.1.5 scale, na deposit formed from solution directlyupon a surface.3.1.6 sludge, na water-formed sedimentary deposit.3.2 Definit
21、ions of Terms Specific to This Standard:3.2.1 acute phase, n of legionellosis, the initial phase ofinfection; the first weeks following symptom onset.3.2.2 aerosol, nsolid or liquid particles suspended in air.3.2.3 antibody, nto legionellae, a substance in bloodsynthesized in response to legionella
22、antigen that enters thebody.3.2.4 antibody rise, n in legionella antibody, an increasein the highest serum dilution at which legionella antibody isdetected in a blood sample collected weeks or months afterlegionellosis onset as compared with the highest dilution for asample collected before or short
23、ly after illness onset.3.2.5 antigen, nto legionellae, a legionella molecule thatstimulates an antibody response by a host immune system.3.2.6 aseptically, advusing precautions to prevent con-tamination of samples by microorganisms.3.2.7 back-flow preventer, na control valve to preventreverse flow o
24、f water.3.2.8 bacterium, npl. -ria, typically small unicellularmicroorganism.3.2.9 biocide, nfor legionellae, a chemical used to killlegionellae and other microorganisms.3.2.10 biofilm, na layer of microorganisms contained in amatrix that may form a slime on surfaces in contact with water.3.2.11 CDC
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD59522002STANDARDGUIDEFORINSPECTINGWATERSYSTEMSFORLEGIONELLAEANDINVESTIGATINGPOSSIBLEOUTBREAKSOFLEGIONELLOSISLEGIONNAIRESDISEASEORPONTIACFEVER

链接地址:http://www.mydoc123.com/p-521111.html