ASTM D3523-1992(2007) Standard Test Method for Spontaneous Heating Values of Liquids and Solids (Differential Mackey Test)《液体和固体的自然热值标准试验方法(差示麦克法)》.pdf
《ASTM D3523-1992(2007) Standard Test Method for Spontaneous Heating Values of Liquids and Solids (Differential Mackey Test)《液体和固体的自然热值标准试验方法(差示麦克法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3523-1992(2007) Standard Test Method for Spontaneous Heating Values of Liquids and Solids (Differential Mackey Test)《液体和固体的自然热值标准试验方法(差示麦克法)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3523 92 (Reapproved 2007)An American National StandardStandard Test Method forSpontaneous Heating Values of Liquids and Solids(Differential Mackey Test)1This standard is issued under the fixed designation D 3523; the number immediately following the designation indicates the year ofor
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the non-adiabatic determinationof th
3、e spontaneous heating values (SHV) of liquids and solids.It is applicable to substances that are not completely volatile atthe test temperature. Spontaneous heating values obtained bythis test method are qualitative indications of the degree ofself-heating that may be expected to occur upon exposure
4、 ofthe sample to air at the test temperature.1.2 Values obtained by this method are applicable to liquidsand solids supported on cellulosic surfaces. They are notapplicable to liquids on metal surfaces, on contaminatedsurfaces, or at pressures above atmospheric.1.3 Spontaneous heating values determi
5、ned by the presenttest method are regarded only as qualitative measurements ofself-heating which occurs under the conditions of the test. Thetest method does not purport to produce a quantitative measureof the enthalpy of reaction of the sample with air at a given testtemperature. Such data can be o
6、btained by the use of anadiabatic calorimeter. The existence, under the test conditions,of a positive temperature difference between the sample andthe reference is evidence of a thermochemical reaction in thesample.1.4 The magnitude of the measured temperature differenceis a semiquantitative indicat
7、ion of the enthalpy and rate of thatreaction. Since factors such as heat loss from the sample to thebath and quenching of the reaction due to too rapid consump-tion of oxygen affect the amount and duration of the measuredheat effect, care must be taken not to attribute too muchquantitative significa
8、nce to the test results. It is sufficient, forthe purpose of this test, to determine whether or not the sampleis capable of undergoing a self-heating reaction of sufficientmagnitude and rapidity to produce a detectable thermal effect.The spontaneous heating value (SHV) can be lower than thetest temp
9、erature. A negative result does not preclude sponta-neous heating initiating at a temperature higher than the testtemperature.1.5 This standard should be used to measure and describethe response of materials, products, or assemblies to heat andflame under controlled conditions and should not be used
10、 todescribe or appraise the fire-hazard or fire-risk of materials,products, or assemblies under actual fire conditions. However,results of this test may be used as elements of a fire-hazardassessment or a fire-risk assessment which takes into accountall of the factors which are pertinent to an asses
11、sment of the firehazard or fire risk of a particular end use.1.6 The values stated in SI units are to be regarded as thestandard. In cases where materials, products or equipment areavailable in inch-pound units only, SI units are omitted.1.7 This standard does not purport to address all of thesafety
12、 concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent W
13、ater3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 spontaneous heating value (SHV)the maximumamount by which the temperature of the sample exceeds that ofthe reference when exposed at a given temperature in thestandard apparatus.3.2 Symbols:tS= temperature of sample side at a
14、ny time during test,K,tR= temperature of reference side at time tSis measured,K,TS= maximum temperature of sample chamber duringtest, K,1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.11 on Engi
15、neering Sciences of High Performance Fluids and Solids.Current edition approved May 1, 2007. Published June 2007. Originallyapproved in 1976. Last previous edition approved in 2002 as D 3523 92 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servi
16、ce at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.TR= temperature of reference chamber measured
17、 at sametime that TSis measured, K,Dt = tS tR,DT = TS TR,BR= equilibrium temperature of reference side duringblank run, K,BS= equilibrium temperature of sample side duringblank run, K,DTB= BS BR= instrumental blank,DtC= Dt (BSBR)=Dt DTB, andDTC= DT (BS BR)=DT DTB= spontaneous heatingvalue.4. Summary
18、 of Test Method4.1 The sample is supported on surgical gauze and placed ina heated chamber which is open to the air at the top. Thetemperature of the sample, thus prepared, is compared to thatof an equal reference quantity of surgical gauze contained in anidentical chamber. The amount by which the t
19、emperature of thesample exceeds that of the reference is taken as an index of thespontaneous heating value of the sample. Tests may beconducted for durations of 4 to 72 h or longer if desired.4.1.1 Any convenient, inert, fibrous substrate of adequateabsorbency may be substituted for surgical gauze a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD352319922007STANDARDTESTMETHODFORSPONTANEOUSHEATINGVALUESOFLIQUIDSANDSOLIDSDIFFERENTIALMACKEYTEST

链接地址:http://www.mydoc123.com/p-514932.html