ASTM D3123-2009(2017) Standard Test Method for Spiral Flow of Low-Pressure Thermosetting Molding Compounds《低压热固性成型混合料螺旋流的标准试验方法》.pdf
《ASTM D3123-2009(2017) Standard Test Method for Spiral Flow of Low-Pressure Thermosetting Molding Compounds《低压热固性成型混合料螺旋流的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3123-2009(2017) Standard Test Method for Spiral Flow of Low-Pressure Thermosetting Molding Compounds《低压热固性成型混合料螺旋流的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3123 09 (Reapproved 2017)Standard Test Method forSpiral Flow of Low-Pressure Thermosetting MoldingCompounds1This standard is issued under the fixed designation D3123; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for measuring thespiral flow of thermosetting molding compounds (soft or
3、 verysoft) designed for molding pressures under 6.9 MPa (1000 psi).It is especially suited for those compounds used for encapsu-lation or other low pressure molding techniques. It involves theuse of a standard spiral flow mold in a transfer molding pressunder specified conditions of applied temperat
4、ure and pressurewith a controlled charge mass.1.2 The values stated in SI units are to be regarded asstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safet
5、y and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this test method.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Dec
6、ision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD958 Practice for Determining Temperatures
7、of StandardASTM Molds for Test Specimens of Plastics (Withdrawn1995)3E105 Practice for Probability Sampling of Materials3. Terminology3.1 DefinitionsDefinitions in this test method are consis-tent with Terminology D883.4. Significance and Use4.1 The spiral flow of a thermosetting molding compound is
8、a measure of the combined characteristics of fusion underpressure, melt viscosity, and gelation rate under specificconditions.4.2 This test method is useful as a quality control test and asan acceptance criterion.4.3 This test method, by itself, is not a valid means forcomparing the moldability of s
9、imilar or different moldingcompounds because it cannot duplicate actual conditionsprevalent in different types of production molds.4.4 This test method is presently intended for use at atransfer pressure of 6.9 MPa (1000 psi) and a mold temperatureof 423 6 3 K (150 6 3C (302 6 5F).5. Apparatus5.1 Tr
10、ansfer Molding Press with a minimum 150 by150-mm (6 by 6-in.) platen area, transfer piston pressurepotentially greater than 6.9 MPa (1000 psi), sufficient clamppressure to prevent flashing, and a minimum plunger speed of25.4 mm (1 in.)/s without load. It is recommended that theplunger be equipped wi
11、th at least one peripheral sealinggroove. It is recommended that a pot diameter between 31.75and 44.45 mm (1.25 and 1.75 in.) be used whenever a choiceis possible.NOTE 2Preliminary evidence indicates that, in many cases, reasonablecorrelations may be achieved between laboratories using presses withd
12、ifferent pot diameters. Typical examples are presses with pot diameters of31.750, 38.100, and 44.450 mm (1.250, 1.500, and 1.750 in.). However, afew well-documented cases are recorded where differences in potdiameters, even within this listed range, have caused large differences inflow-length readin
13、gs. Therefore, for best interlaboratory correlation it isrecommended that identical pot diameters be used.5.2 Standard Spiral-Flow Mold shown in Fig. 1 shall beutilized.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.3
14、0 on Thermal Properties(Section D20.30.08).Current edition approved Aug. 1, 2017. Published August 2017. Originallyapproved in 1972. Last previous edition approved in 2009 as D3123 - 09. DOI:10.1520/D3123-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custome
15、r Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, Wes
16、t Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Tr
17、ade Organization Technical Barriers to Trade (TBT) Committee.16. Materials6.1 Molding Compound:6.1.1 Any thermosetting molding compound with a spiralflow between 762 and 1270 mm (30 and 50 in.) as determinedat the standard temperature and pressure of this test can beevaluated.NOTE 3Since the only co
18、mmercially available molds are calibrated ininches, spiral-flow length will be reported in these units. Conversion to SIunits can readily be made by multiplying the flow length, in inches, by theappropriate conversion factor, 25.4 mm/in.NOTE 4There is considerable evidence that the test is usable ov
19、er awider range of flow lengths, but this has not yet been confirmed byinterlaboratory testing.6.1.2 FormThe form of the molding compound shall beloose powder or granules at 296 6 2 K (23 6 2C (73.4 63.6F).NOTE 5Preforms or pellets may be used if found necessary; however,flow length may be affected
20、by their use.7. Sampling7.1 Unless otherwise agreed upon between the seller andpurchaser, sampling shall be in accordance with Practice E105.Sampling, based on engineering principles, prior to packagingshall be considered an acceptable alternative.8. Conditioning8.1 ConditioningAll molding compounds
21、 shall be testedin “as-received” condition. For referee testing, all materialshall be shipped and stored in moisture-barrier containers.They shall be stored for a minimum of 24 h at the standardlaboratory temperature, before breaking the seal on the con-tainer. Take care to preserve the “as-received
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD312320092017STANDARDTESTMETHODFORSPIRALFLOWOFLOWPRESSURETHERMOSETTINGMOLDINGCOMPOUNDS 低压 热固性 成型

链接地址:http://www.mydoc123.com/p-514109.html