1、Designation: C 371 09Standard Test Method forWire-Cloth Sieve Analysis of Nonplastic Ceramic Powders1This standard is issued under the fixed designation C 371; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the particlesize distribution of nonplastic ceramic powders such as alu-mina, silic
3、a, feldspar, pyrophyllite, nepheline syenite, talc,titanates, and zircon using wire cloth sieves.1.2 Materials containing a large amount of fines, containingagglomerates, or that are nonfree-flowing, are wet-sieved toremove excessive fines or to disperse agglomerates beforeperforming the test. This
4、technique is not applicable to mate-rials that are, to any degree, water soluble.1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units, or are other customary units(in the case of sieve frame diameter and siev
5、e number), that areprovided for information only and are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and de
6、termine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 322 Practice for Sampling Ceramic Whiteware ClaysE11 Specification for Wire Cloth and Sieves for TestingPurposes3. Significance and Use3.1 Sieve analyses are carried out to determine the pa
7、rticlesize distribution of powders which, in turn, are used to qualifythose materials as to their usefulness in the process underconsideration. Since particle size analyses have only relativesignificance, the results should be considered only where theycorrelate with process characteristics. The par
8、ameter that isbeing measured in this test is the amount of material that willpass through a cloth having theoretically square openings. Itmust be remembered that all the holes are not square, noruniform in size, and the question of whether a given particlewill go through is a statistical one. Since
9、each particle sizeanalysis method measures a unique physical parameter, theresults from one method may not agree with those fromanother. Particle size distributions play a role in such propertiesas bulk density, dustiness, and handling characteristics. Careshould be taken, however, when interpretati
10、ons are made fromone or two points (sieves) on the distribution curve.4. Apparatus4.1 Balance, having a sensitivity of 0.05 g.4.2 Sieves, clean, unblinded, 205 mm (8 in.) in diameter,and conforming to Specification E11.At all times they shall becertified by, or shall be calibrated with sieves certif
11、ied by, theNational Institute of Standards and Technology. For wet-sieving, use full-height 50-mm (2-in.) sieves; these sieves andpan may be used for dry-sieving also. Half-height 25-mm(1-in.) sieves and pan shall be used for dry-sieving only. Thesieves to be used may range from 45 m (No. 325) throu
12、gh 212m (No. 70).4.3 Drying Pans, about 205 mm (8 in.) in diameter and 25or 50 mm (1 or 2 in.) high.4.4 DryerFor drying, the use of an oven maintainedautomatically at 100 to 110C is recommended.4.5 Mechanical Shaking DeviceThe shaking device shallbe such as to produce a lateral and vertical motion o
13、f the sieve,accompanied by a jarring action so as to keep the samplemoving continuously over the surface of the sieve.4.6 In wet-sieving, the water should be slightly above roomtemperature (for example, a hot-cold mixer tap) and should besupplied by means of a fixed or hand-held spray.5. Sampling5.1
14、 Unit for SamplingEach carload shall be considered aunit for sampling.5.2 Gross Sample (See Practice C 322)In collecting thegross sample from a carload shipped in bags, select a numberof bags equivalent to not less than 1 % of the total number ofbags in the car. Bags taken for sampling shall be from
15、 locationsevenly distributed, horizontally and vertically, throughout thecar. The gross sample shall consist of equal increments of notless than 227 g (0.5 lbs) from each of the bags taken for1This method is under the jurisdiction of ASTM Committee C21 on CeramicWhitewares and Related Products and i
16、s the direct responsibility of SubcommitteeC21.04 on Raw Materials.Current edition approved Jan. 1, 2009. Published February 2009. Originallyapproved in 1955. Last previous edition approved in 2003 as C 371 89 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AST
17、M Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC3712009STANDARDTESTMETHODFORWIRECLOTHSIEVEANALYSISOFNONPLASTICCERAMICPOWDERS 塑性 陶瓷 粉末 金属丝 筛分 标准

链接地址:http://www.mydoc123.com/p-466399.html