1、Designation: C1689 08a (Reapproved 2014)Standard Practice forSubsampling of Uranium Hexafluoride1This standard is issued under the fixed designation C1689; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is applicable to subsampling uraniumhexafluoride (UF6), using heat liquefaction techniques, frombulk containers, obtain
3、ed in conformance with C1052, intosmaller sample containers, which are required for laboratoryanalyses.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 It is assumed that the liquid UF6being sampled com-prises a single qu
4、ality and quantity of material. This practicedoes not address any special additional arrangement that mightbe required for taking proportional or composite samples.1.4 The number of samples to be taken, their nominalsample weight, and their disposition shall be agreed uponbetween the parties.1.5 The
5、 scope of this practice does not include provisionsfor preventing criticality incidents.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
6、 and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C787 Specification for Uranium Hexafluoride for Enrich-mentC859 Terminology Relating to Nuclear MaterialsC996 Specification for Uranium Hexafluoride Enriched toLess Than 5 %235UC761 Te
7、st Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and RadiochemicalAnalysis ofUranium HexafluorideC1052 Practice for Bulk Sampling of Liquid UraniumHexafluoride2.2 Other Documents:ANSI N14.1 Uranium Hexafluoride: Packaging for Trans-port3ISO/DIS 7195 Packaging of Uranium Hexafluo
8、ride (UF6)for Transport4USEC-651 The UF6Manual: Good Handling Practices forUranium Hexafluoride, latest revision53. Terminology3.1 Terms shall be defined in accordance with TerminologyC859 except for the following:3.1.1 sample bottlethe vessel (typically a 1S or 2S bottle)into which the sample of UF
9、6is withdrawn from the containerfor transfer to the laboratory, analysis or dispatch to thecustomer.3.1.2 subsample tubethe small vessel (for example, a P10tube6) into which a subsample of UF6is withdrawn from thesample bottle for analysis of UF6quality or dispatch to thecustomer.3.1.3 subsample rig
10、the equipment to perform the transferof liquid UF6from the sample bottle into the subsample tube,typically a vacuum manifold equipped with heating and aliquid nitrogen trap.4. Summary of Practice4.1 Two methods of withdrawing a subsample of UF6aredescribed which differ based on safety requirements n
11、amely:1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Current edition approved Jan. 1, 2014. Published February 2014. Originallyapproved in 2008. Last previous edition approved in 2008 as C1
12、689 08a. DOI:10.1520/C1689-08aR14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Na
13、tional Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from International Organization for Standardization (ISO), 1, ch. dela Voie-Creuse, Case postale 56, CH-1211, Geneva 20, Switzerland, http:/www.iso.ch.5Available from United States Enrichme
14、nt Corp., 6903 Rockledge Dr., Bethesda,MD 20817, http:/.6Polychlorotrifluoroethylene P10 tubes are widely accepted by the industry forsubsample collection and subsequent UF6quality analyses or dispatch to thecustomer. Other types of subsample tubes, for example P-20, P-80 or P100 , can beused for in
15、ternal subsample collection and processing. Dispatch of these subsampletubes may be agreed upon by buyer and seller and subject to (local) transportregulations.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1(1) homogenizing of liquef
16、ied UF6by agitation before liquidtransfer and (2) homogenizing of liquefied UF6by convectionbefore liquid transfer. The first method involves homogeniza-tion of liquified UF6in a sample bottle by vigorous shaking.Subsequently the sample bottle is inverted and connected to thetop of a heated vacuum-m
17、anifold system, and the subsampletube is attached to the appropriate port of the system. Thesystem is evacuated and the liquid UF6allowed to flow bygravity into the subsample tube. In the second method thesample bottle containing solid UF6is connected to the top of amanifold system, and a subsample
18、tube is attached to theappropriate port of the system.The whole system is enclosed insecondary containment that can be heated (hot-box). Afterevacuation the complete system is heated for specific period(typically 1.5 hr) to allow for complete homogenization ofthe liquid UF6by convection. Subsequentl
19、y the liquid UF6isallowed to flow by gravity either directly or via graduatedvolume into the subsample tube.4.2 For both methods of sampling, the presence of residuesmay have significant implications for the quality of UF6. Forsafety and quality reasons, sample bottles and subsample tubesshall be cl
20、ean, dry, and empty before filling.4.3 Various types of sample bottles and tubes are in use andare described in detail in the applicable national and interna-tional standards, for example, ANSI N14.1 and ISO/DIS 7195.For a given type of sample bottle, the detailed configuration,for example valve ori
21、entation, terminal fittings and the like,may vary. Hence the type and configuration of bottles used forthe withdrawal of samples shall be agreed upon between theparties.5. Significance and Use5.1 Uranium hexafluoride is normally produced and handledin large (typically 1- to 14-ton) quantities and mu
22、st, thereforebe characterized by reference to representative samples. Thesamples are used to determine compliance with the applicablecommercial Specifications C996 and C787 by means of theappropriate test method (for example, Test Method C761 andreferences therein). The quantities involved, physical
23、properties, chemical reactivity, and hazardous nature of UF6are such that for representative sampling, specially designatedequipment must be used and operated in accordance with themost carefully controlled and stringent procedures. This prac-tice indicates appropriate principles, equipment and proc
24、edurescurrently in use for subsampling of liquid UF6. It is used byUF6converters, enrichers and fuel fabricators to review theeffectiveness of existing procedures or to design equipment andprocedures for future use. Other subsampling procedures suchas UF6vapor sampling are not directly representativ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16892008A2014STANDARDPRACTICEFORSUBSAMPLINGOFURANIUMHEXAFLUORIDE 氟化 二次 采样 标准 操作规程 PDF

链接地址:http://www.mydoc123.com/p-465531.html