ASTM A577 A577M-1990(2007) Standard Specification for Ultrasonic Angle-Beam Examination of Steel Plates《钢板的超声角波束检验的标准规范》.pdf
《ASTM A577 A577M-1990(2007) Standard Specification for Ultrasonic Angle-Beam Examination of Steel Plates《钢板的超声角波束检验的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM A577 A577M-1990(2007) Standard Specification for Ultrasonic Angle-Beam Examination of Steel Plates《钢板的超声角波束检验的标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 577/A 577M 90 (Reapproved 2007)Standard Specification forUltrasonic Angle-Beam Examination of Steel Plates1This standard is issued under the fixed designation A 577/A 577M; the number immediately following the designation indicates the yearof original adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification2covers an ultrasonic angle-beamprocedure and acceptance standards for the detecti
3、on of inter-nal discontinuities not laminar in nature and of surface imper-fections in a steel plate. This specification is intended for useonly as a supplement to specifications which provide straight-beam ultrasonic examination.NOTE 1An internal discontinuity that is laminar in nature is onewhose
4、principal plane is parallel to the principal plane of the plate.1.2 Individuals performing examinations in accordance withthis specification shall be qualified and certified in accordancewith the requirements of the latest edition of ASNT SNT-TC-1A or an equivalent accepted standard. An equivalentst
5、andard is one which covers the qualification and certificationof ultrasonic nondestructive examination candidates and whichis acceptable to the purchaser.1.3 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in b
6、rackets. The values stated in eachsystem are not exact equivalents; therefore, each system mustbe used independently of the other. Combining values from thetwo systems may result in nonconformance with the specifi-cation.2. Referenced Documents2.1 ASNT Standards:3SNT-TC-1A Recommended Practice for P
7、ersonnel Qualifi-cation and Certification in Nondestructive Testing3. Ordering Information3.1 The inquiry and order shall indicate any additions to theprovisions of this specification as prescribed in 11.1.4. Examination Conditions4.1 The examination shall be conducted in an area free ofoperations t
8、hat interfere with proper performance of theexamination.4.2 The surface of the plate shall be conditioned as neces-sary to provide a clear, easily interpreted trace pattern on thescreen. Any specified identification which is removed toachieve proper surface smoothness shall be restored.5. Apparatus5
9、.1 The amplitude linearity shall be checked by positioningthe transducer over the depth resolution notch in the IIW orsimilar block so that the signal from the notch is approximately30 % of the screen height, and the signal from one of the backsurfaces is approximately 60 % of the screen height (two
10、 timesthe height of the signal from the notch). A curve is then plottedshowing the deviations from the above established 2:1 ratiothat occurs as the amplitude of the signal from the notch israised in increments of one scale division until the backreflection signal reaches full scale, and then is low
11、ered inincrements of one scale division until the notch signal reachesone scale division. At each increment the ratio of the twosignals is determined. The ratios are plotted on the graph at theposition corresponding to the larger signal. Between the limitsof 20 % and 80 % of the screen height the ra
12、tio shall be within10 % of 2:1. Instrument settings used during inspection shallnot cause variation outside the 10 % limits established above.5.2 The search unit shall be a 45-deg (in steel) angle-beamtype with active transducer length and width dimensions of aminimum of12 in. 12.5 mm and a maximum
13、of 1 in. 25mm. Search units of other sizes and angles may be used foradditional exploration and evaluation.6. Examination Frequency6.1 The ultrasonic frequency selected for the examinationshall be the highest frequency that permits detection of the1This specification is under the jurisdiction of AST
14、M Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.11 on Steel Plates for Boilers and Pressure Vessels.Current edition approved March 1, 2007. Published March 2007. Originallyapproved in 1967. Last previous edition approved in 2001 as A 57
15、7/A 577M 90 (2001).2For ASME Boiler and Pressure Vessel Code applications, see related Specifi-cation SA-577/SA-577M in Section II of that Code. Available from AmericanSociety of Mechanical Engineers (ASME), ASME International Headquarters,Three Park Ave., New York, NY 10016-5990, http:/www.asme.org
16、.3Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.required calibration notch, such that
17、the amplitude of theindication yields a signal-to-noise ratio of at least 3:1.7. Calibration Reflector7.1 A calibration notch, the geometry of which has beenagreed upon by the purchaser and the manufacturer, with adepth of 3 % of the plate thickness, shall be used to calibratethe ultrasonic examinat
18、ion. The notch shall be at least 1 in. 25mm long.7.2 Insert the notch or notches on the surface of the plate sothat they are perpendicular to the long axis at a distance of 2 in.50 mm or more from the short edge of the plate. Locate thenotch not less than 2 in. 50 mm from the long edges of theplate.
19、7.3 When the notch cannot be inserted in the plate to betested, it may be placed in a calibration plate of ultrasonicallysimilar material. The calibration plate will be consideredultrasonically similar if the height of the first back reflectionthrough it is within 25 % of that through the plate to b
20、e testedat the same instrument calibration. The calibration platethickness shall be within 1 in. 25 mm of the thickness ofplates to be tested, for plates of 2 in. 50 mm thickness andgreater and within 10 % of plates whose thickness is less than2 in. 50 mm.7.4 For plate thicknesses greater than 2 in.
21、 50 mm, inserta second calibration notch as described in 7.2, on the oppositeside of the plate.8. Calibration Procedure8.1 Plate 2 in. 50 mm and Under in Thickness:8.1.1 Place the search unit on the notched surface of theplate with the sound beam directed at the broad side of thenotch and position t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA577A577M19902007STANDARDSPECIFICATIONFORULTRASONICANGLEBEAMEXAMINATIONOFSTEELPLATES 钢板 超声 波束 检验

链接地址:http://www.mydoc123.com/p-458834.html