ARMY MIL-T-71029 A-1992 TELESCOPE ELBOW 9356181《9356181曲折望远镜》.pdf
《ARMY MIL-T-71029 A-1992 TELESCOPE ELBOW 9356181《9356181曲折望远镜》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-T-71029 A-1992 TELESCOPE ELBOW 9356181《9356181曲折望远镜》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、VIL-T-L029A 9999906 1700499 702 D I NCt! -POUN MIL-T-71029A (AR) SUPERSEDING 30 October 1992 MIL-T-71029 (AR) 02 May 1991 MILITARY SPECIFICATION TELESCOPE, ELBOW: 9356181 This specification is approved for use by the U.S. Army Armament, Munitions and Chemical Command, and is available for use by all
2、 Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the general requirements and tests for the 4-power fixed focus elbow telescope which is the optical portion of Sightunit: M67. Throughout this specification this instrument is referenced as “telesco
3、pe.“ This telescope has a radioactively illuminated reticle (see 3.2.1 and 6.1). 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this docu- ment to the extent specified herein. Unl
4、ess otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS MIL I TARY MIL-0-13830 - OrLical Components for Fire Control In
5、struments; General Specification Governing the Manufacture, Assembly, and Inspection of fication Governing the Manufacture ar,d Inrpection of MIL-F-13926 - Fire Control Materiel; General Speci- l be conducted with the unaided eye utilizing the shadowig technique while viewing through the objective a
6、nd eyepiece ends of the telescope. The optical system of the telescope shall conform to the requirements of 3.3.7. 4.7.1.8 External tritium contamination. The contamination test shall be performed by wiping all surfaces of the item under test witk filter paper moistened with deionized or distille? w
7、ater. The amount of tritium contamination on the filter paper shall be deter- mined by using a liquid scintillation counting technique. The paper shall be placed in the liquid scintillation solution within one minute after wiping the scope. The liquid scintillation counting system shall have suffici
8、ent sensitivity to detect a lower limit of detection of 10 picocuries within 95 percent confidence limit. This test shall be performed by the contractor. The contractor shall furnish filter paper, solution, and bottles. The damp filter paper shall be placed in a container with the proper percentage
9、of scintillation liquid. Insert the sample into this systE.n, count a minimum of 2000 disintegrations (If 2000 disintegztions is not reached in one ho-dr, discontinue the count) and con:ert the readout 4 into microcuries (222 DPM x 10 = 1 microcurie). The measured contamination shall be within the l
10、imits specified in 3.3.8. The liquid scintillating system must be calibrated, on six-month intervals, to a standard traceable to anN.S.T. standard. 4.7.1.9 Diffusion test. Completed scopes, with all luminous vials installed, shall be submerged ir. a measured volum?. of distilled or deionized water e
11、qual to approximately 10 times the valume of the scope for 24 hours at 23O + 5OC. the water. The water shall be analyzed in accordance with the anzlytical procedures defined below: Scopes shall then be removed from a. This is the test procedure for tritium diffusion, and if the radioactive content o
12、f the water exceeds 50 nanocurler/day, it shall constitute failure of the test. b. Analysis of tritium content in th3 diffurion test shall be made with a liquid scintillation counter. The system calibration shall bc established using quenched standards. Total system plus 13 Provided by IHSNot for Re
13、saleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-71029A (AR) standards errors in the standardization shall not be in excess of 10 percent. Efficiencies of the unknown samples shall be established by the channels-ratio method, the external channels-ratio method, or the “
14、H“ number method of quench compensation. Counting time shall be established as such that at the test limits, the error (one standard deviation) shall not be greater than 15 percent. The scintillation solution shall be an acceptable commercial water soluble liquid scintillation cocktail. The counting
15、 bottles shall be a low potassium liquid scintillation borosilicate glass bottle or polyethylene liquid scintillation vial. lation vials are used, a set of quench standards traceable to the National Institute of Standards and Technology shall be made up in the polyethylene vials to determine efficie
16、ncy. standards are in glass bottles, a correction factor shall be deter- mined so that the correct results will be obtained from samples in polyethylene scintillation vials. when polyethylene scintil- If the quench 4.7.2 Performance. 4.7.2.1 Collimation test. This test shall be performed by means of
17、 a surface plate, “V“ block and a target projector collimator having a clear aperture of at least 2.0 inches. A collimating telescope of at least 3 power (3X) containing a horizontal and vertical reticle line shall also be utilized for alignment of the target projector collimator target reticle. con
18、tain a 1.0 mil diameter circle at the intersecting point of the horizontal and vertical reticle lines to determine conformance with collimation, as specified in 3.4.1. Tolerance marks shall also be incorporated on both sides of the vertical reticle line to determine conformance to parallelism of ret
19、icle image, as specified in 3.4.4. Unless otherwise specified, the target projector collimator shall be set at infinity focus. b. Target reticle alignment shall be accomplished by placing the 3 power (3X) collimating telescope in the “V“ block seated on the surface plate. Direct the line of sight of
20、 the collimating telescope toward a plumb line and plumb the vertical reticle line. Position the target projector collimator and establish coincidence of the horizontal and vertical reticle lines on the target projector collimator reticle with the respective crosslines on the collimating telescope r
21、eticle. position the telescope under test in the lvll block. Observe where the intersecting point of the telescope reticle centerlines falls with respect to the intersecting point on the target reticle. Conformance with 3.4.1 shall be considered acceptable if the intersecting point of the telescope
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT71029A1992TELESCOPEELBOW93561819356181 曲折 望远镜 PDF

链接地址:http://www.mydoc123.com/p-448976.html