ARMY MIL-PRF-62198A-1995 VALVE SELECTOR HYDRAULIC DUMP《液压垃圾倾倒装置选择阀》.pdf
《ARMY MIL-PRF-62198A-1995 VALVE SELECTOR HYDRAULIC DUMP《液压垃圾倾倒装置选择阀》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-62198A-1995 VALVE SELECTOR HYDRAULIC DUMP《液压垃圾倾倒装置选择阀》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-PRF-b219A 979990b 2010242 ir53 1 INCH-POUNDS I 7 November 1995 SUPERSEDING MIL-V-62198(AT) 31 May 1983 MIL-PRF-62198A(AT) PERFORMANCE SPECIFICATION VALVE, SELECTOR, HYDRAULIC DUMP This specification is approved for use within U.S. Army Tank- automotive and Armaments Command, Department of the Ar
2、my, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the M60 tank selector valve assembly which allows the pressure of the hydraulic system to be dumped (see 6.1). Beneficial comments (recommendations, additions, del
3、etions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-E, Warren, MI 48397-5000 by using the Standardization Document Improvement Proposal (DD Form 14261, appearing at the end of this docum
4、ent, or by letter. AMSC N/A FSC 4820 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-b219A M 9990b 2010243 39T M 2. APPLICABLE DOCUMENTS 2.1 General. The docum
5、ents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this lis
6、t, document users are cautioned that they must meet ali specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, and standards. The following specifications, and standards, form a part of this do
7、cument to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE
8、 MIL-H-46170 - Hydraulic Fluid, Rust Inhibited, Fire-resistant, Synthetic Hydrocarbon Base. STANDARDS DEPARTMENT OF DEFENSE MIL-STD-810 - Environmental Test Methods. MIL-STD-1246 - Product Cleanliness Levels and Contamination Control Program. (Unless otherwise indicated, copies of the above specific
9、ations, standards, and handbooks are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11 -5094.) 2.2.2 Other.-GaY_eniment documents, .drawings, and publications. The following other Government documents, drawings, and publications form a p
10、art of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - _ MIL-PRF-b23SA = 777970b 2030244 226 MIL-PRF-62198A(AT) DRAWINGS DE
11、PARTMENT OF DEFENSE 1 1674266 - Valve, Selector. (Copies of these drawings are available from the U.S. Army Tank-automotive and Armaments Command, Warren, MI 48397-5000.) 2.3 Nnnr.G.oscernment publications. The following documents form a part of this document to the extent specified herein. Unless o
12、therwise specified, the issues of the documents that are adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the non-government documents that are current on the date of the soli
13、citation (see 6.2). AMERICAN SOCIETY FOR QUALITY CONTROL (ASQC) ANSI/ASQC 21.4 - Sampling Procedures and Tables for Inspections by Attributes, (Application for copies should be addressed to The Society for Quality Control, P.O. Box 305,611 E. Wisconsin Ave., Milwaukee, WI 53201-4606.) 2.4 Order of p
14、recedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification takes precedence. Nothing in this specification, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREM
15、ENTS 3.1 First article. When specified (see 6.2), a first article sample shall be subjected to first article inspection in accordance with 4.2. 3.2 Materials. Materials used shall be in accordance with the manufacturers materials specifications for valve selector assemblies. The materials shall be c
16、apable of meeting all of the operational and environmental requirements specified herein. Recovered materials shall be used to the maximum extent practicable (see 4.6.1). 3.2.1 Material compatibility. Selector valve assembly materials shall be compatible with hydraulic fluid per MIL-H-46170 (see 4.6
17、.1). 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-62lt9A m 999990b 2010245 1b2 W 3.2.2 Corrosion control. The selector valve assembly shall be fabricated from materials that are inherently corrosion resistant or are permanently treated
18、to prevent forms of corrosion and deterioration which affect system performance (see 4.6.1). 3.3 Design and construction. Selector valve assembly shall conform to the manufacturers design and construction except for the envelope dimensions; port hole dimensions, locations, and depth; lever swing rad
19、ius and location; and mounting dimensions which shall conform to drawing 11674266 and other applicable drawings (see 4.6.2). 3.3.1 Interchangeability. All selector valve assemblies shall be interchangeable as to fit, form, and function with other manufacturers assemblies having the same military par
20、t number (see 4.6.2). 3.3.2 Weight. The dry weight of the selector valve assembly shall not exceed 2 pounds (0.9 kilogram (kg) (see 4.6.2). 3.4 Performance. 3.4.1 Torque. The torque required to move the handle out of the open or closed detented positions shall be 8 + 6 inch pounds (0.9 + 0.68 Newton
21、-meter (N-m) with 1000 pounds per square inch gage (psig) (6.88 Megapascal (MPa) of hydraulic fluid applied to port 1 with port 2 blocked (see drawing 11674266). The torque required to move the handle between detent positions shall not exceed 15 inch pounds (1.7 N-m) (see 4.6.4). 3.4.2 Pressure drop
22、. Pressure differential between port 1 and port 2 shall not exceed 750 psi (5.16 MPa) at a minimum flow of 5 gallons per minute (gpm) (18.9 liters per minute (L/min) when the handle is in the open position. Pressure differential at environmental extremes shall not exceed 1500 psi (7.9 MPa) (see 4.6.
23、5). 3.4.3 External leakage. There shall be no external leakage of the selector valve (see 4.6.6). 3.4.4 Internal leakage. With the valve handle in the closed position, the leakage from port 2 shall not exceed 0.003 cubic inches (in3) (0.05 cubic centimeters (cm3) per minute at any pressure applied t
24、o port 1 up to 3000 psig (20.6 MPa). Leakage from port 2 shall not exceed 0.006 in3 (0.1 cm3) per minute after endurance performance (see 4.6.7). 3.4.5 Proof pressure. Selector valve, in the closed position, shall withstand a minimum pressure of 4500 psig (31 MPa) for a duration of 3 minutes without
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62198A1995VALVESELECTORHYDRAULICDUMP 液压 垃圾 倾倒 装置 选择 PDF

链接地址:http://www.mydoc123.com/p-447551.html