1、MIL-PRF-L17b?G 999970b 2057453 034 IINCH-POUND I MIL-PRF- 1 1767G(AT) 12 December 1997 SUPERSEDING 4 June 1991 MlL-R-l1767F(AT) PERFORMANCE SPECIFICATION RELAY ASSEMBLY: GUN-FIRING, WATERPROOF, 24 VOLT DC This specification is approved for use by the U.S. Army Tank-automotive and haments Command, De
2、partment of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of waterproof gun-firing relay assembly with a nominal rating of 24 volts circuits of military combat vehicles. The assembly consists of
3、 relays which control the firing of the main gun by the operation of a time delay circuit and a separate fast-operating, fast-release relay which controls the firing of the machine gun (see 6.1). direct current (dc) for use in the main gun and machine gun 2. APPLICABLE DOCUMENTS 2.1 General. The doc
4、uments listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this l
5、ist, document users are cautioned that they must meet aii specified requirement documents cited in sections 3 and 4 of this specification, whether or not they are listed. IBeneficiai comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this documen
6、t should be addressed to: U.S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-EBLUE, Warreq MI 48397-5000, by using the Standardization Document Improvement Proposai (DD Form 1426) appearing at the end of this document, or by letter. AMSC N/A FSC 5945 DISTRIBUTION STATEMENT A Approved fo
7、r public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-LL767G m O6 2057454 T70 m MILPW- 1 1767G(AT) 2.2 Government documents. 2.2.1 other Government documents. drawings. and publications. The following ot
8、her Government documents, drawings, and publications form a part of this document to the extent specied herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWING 8338636 - Relay Assembly, Gun Firing (Interface). (Copies of this drawing are available from the U.S. Ar
9、my Tank-automotive and Armaments Command, AT“: AMSTA-TR-E/BLUE, Warren, MI 48397-5000.) 2.3 Order of mecedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes appl
10、icable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.3. 3.2 Desien materials. and manufiu%ring process. Unless otherwise specified (see 6.2)
11、, the design, materials, and manufhcturing process selection is the prerogative of the contractor as long as ali articles submited to the government fully meet the interface and interoperability, environmental, support and ownership, and operating requirements specified herein. 3.2.1 Recycled. recov
12、erd or environmentallv preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the materia meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.
13、3 Interface and interoperabiity requirements. The relay assembly shall conform to the envelope dimensions, and the electrical and mounting interfaces as shown in Drawing 8338636. 3.3.1 Grounding. The nish around the mounting holes shaU provide positive electrical contact to ground when the assembly
14、is normally mounted. This requirement does not apply to relay assemblies mounted on insulated bases. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-11767G 9999906 2057455 907 MIL-PRF- 1 1767G(AT) 3.3.2 Wei9;ht. The maximum weight of the re
15、lay assembly shall be four pounds (lb). 3.3.3 Mounting bracket. When brackets are used, they shall be an integral part of the housing or shall be securely attached thereto, in a manner to prevent any movement between assembly and the mounting bracket in service. 3.3.4 Polarity. The relay assembly sh
16、all operate in a circuit having the negative battery terminal grounded. 3.4 Environmental requirements. The design, materials, and construction of relay assembly shal enable the unit to operate in the following environmental conditions The relay assembly shall subsequently meet the requirements spec
17、ified in 3.6.1, 3.6.4, 3.6.5, 3.6.7, and 3.6.8. 3.4.1 Vibration. The relay assembly shall evidence no mechanical or electrical malfnction (opening or closing of relay contacts). 3.4.2 Shock. The relay assembly shall evidence no mechanical or electrical malfunction (opening or closing of relay contac
18、ts). 3.4.3 Corrosion. Metals shall be of a corrosion-resistant type or shall be treated to resist corrosion. The relay shali evidence no corrosion. 3.4.4 Waterproofness. The relay assembly shall be waterproof 3.5 Suoprt and ownership requirements. 3.5.1 Materials. The relay assembly shall not produc
19、e any hazards to personnel or the environment resulting from the use of asbestos or cadmium. 3.5.1.1. Dissimilar metals. Except where necessary to complete an electrical circuit, there shall be no contact between dissimilar metals, which would encourage galvanic action. 3.5.2 Springs. Springs shall
20、not be used to transmit current. 3.5.3 Endurance. The relay assembly shall remain mechanically and electrically operative and the voltage drop across the main gun and machine gun relay contacts carrying rated current, shall not exceed the limits specified in 3.6.7. The relay assembly shal subsequent
21、ly meet the requirements of 3.6.1 and 3.6.4 through 3.6.7. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-LL7b7G 99Ob 205745b 843 MIL-PRF- 1 1767G(AT) 3.5.4 Color. Exterior sudiices of the relay assembly housing shall be white. 3.5.5 Ident
22、ification marking. Identification marking shall be permanent and legible and, as a minimum, shall include the following: a. ?Relay assembly: gun-firing? b. ?24 Vdc waterproof? c. Military Part Number (Pl?) (see 6.2) d. Manufacturer?s name e. Manufacturer?s serial number (if applicable) f. Date of ma
23、nufixture (month, year) 3.6 ODerating reauirements. 3.6.1 Time delav. The relay shall provide a time delay (time the main gun-firing relay contacts are closed) between O. 10 and 0.50 seconds throughout the operating voltage range of 18 to 30 Vdc. The relay assembly shall subsequently meet the requir
24、ements specified in 3.5.3 and 3.6.2 through 3.6.8. 3.6.2 Operating current. When the main gun relay is energized, the operating current shall not be more than 0.35 amperes (A). 3.6.3 Dielectric strength. The relay assembly shall evidence no loosening, cracking, burning, smoking, rupturing or any oth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF11767G1997RELAYASSEMBLYGUNFIRINGWATERPROOF24VOLTDC24 直流电 防水 火炮 试射 继电器 组合 PDF

链接地址:http://www.mydoc123.com/p-446980.html