1、MIL-C-47380 58 7777906 0163586 7 1. r MIL-C-49380(ER) 16 June 1980 . MILITARY SPECIFICATION COMMANDERS DISPLAY FOR AN/VSG-2 This specification is approved for use by USAERADCOM, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.
2、1 Scope. This specification covers the Commanders Display for the Sight, Thermal, Tank Mounted, AN/VSG-2. 2. APPLICABLE DOCUMENTS 2.1 Issues of documents. The following documents of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the e
3、xtent specified herein. SPEC IF1 CAT IONS FEDERAL NN-P-71 QQ-S-781 PPP-B-60 1 PPP-F-320 MILITARY MIL-P-116 MIL-B-117 MIL-P-11268 MIL-P-26514 MIL-E-49383 Pallets, Material Handling, Wood, Stringer Construction, 2-Way and 4-Way (Partial) Strapping, Steel, and Seals Boxes, Wood, Cleated-Plywood Fiberbo
4、ard, Corrugated and Solid, Sheet Stock (Container Grade), and Cut Shapes Preservation-Packaging, Methods of Bags, Sleeves and Tubing-Interior Packaging Parts, Materials, and Processes Used in Polyurethane Foam, Rigid or Flexible Eyepiece, Biocular, AN/VSG-2 Electronic Equipment for Packaging Benefic
5、ial comnents (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Hq, USA Electronics Research and Development Command, ATTN: DRDEL-E, 2800 Powder Mill Road, Adelphi, MD 20783 by using the self-addressed Standard- izati
6、on Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. FSC 5855 THIS DOCUMENT CONTAINS /y PAGES. I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-LI7380 54 W 7777906 OLb3587 O m STANDARDS MILITARY M
7、IL-STD-129 MIL-STD-147 MIL-STD-150 MIL-STD-252 MIL-STD-454 MIL-STD-810 MIL-STD-1188 MS-24535 DRAWINGS DLSM-B-804913 SM-C-805906 - Marking for Shipment and Storage - Palletized and Containerized Unit Loads 40 Inch x 48 Inch Pallets, Skids, Runners, or Palletized Type Base - Photographic Lenses - Clas
8、sification of Visual and Mechanical Defects for Equipmert, Electronic, Wired, and Other Devices Electronic Equipment - Standard General Requirements for - Environmental Test Methods - Commercial Packaging of Supplies and - Fastener-Container Closure E quipmen t - Commanders Display, ANfVSG-2 - Image
9、 Intensifier, 40 Millimeter (Copies of specifications, standards, drawings, and publications required by contractors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) I 3. REQUIREMENTS 3.1 Item definition. The
10、 Commanders Display for AN/VSG-2, herein known as the commanders display, relays an image of the infrared scene produced by the ANfVSG-2 from the gunners station to the commanders station. 3.2 Construction. The commanders display shall be constructed in accor- dance with DLSM-B-804913 and as specifi
11、ed herein. 3.3 First article. When specified in the contract (see 6.21, the contractor shall furnish five (5) commanders displays for first article inspection and approval. 3.4 Parts, materials and processes. Parts, materials and processes shall be as specified herein and as shown on the applicable
12、drawings. materials and processes not specified shall be selected in accordance with MIL-P-11268. Parts, 3.5 Major components. The commanders display consists of the following comDonents and subassemblies and shall be constructed in accordance with applicable drawings, specifications and as specifie
13、d herein. 2 - i O, Qp Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-47380 58 7777906 0363588 2 r c a. b. Image Intensifier - SM-C-805906 c. Optical Relay Assembly d. Display Assembly Biocular Eyepiece Display - MIL-E-49383 3.6 Preconditioning
14、. Each commanders display shall be subjected to a 48- hour preconditioning prior to delivery. 3.7 Operation. 3.7.1 Luminance uniformity. With a uniform scene input, the luminance of each display shall not vary more than +i5 percent from the average display luminance over the central 50 percent of th
15、e display. 3.7.2 Power. The commanders display power requirements shall not exceed 5 watts. 3.7.3 Optical transfer function (OTF). The modulation transfer function (MTF) shall satisfy the performance characteristics as shown below over the center of the display in the scan direction, with the system
16、s gain set so that the system is operating within its dynamic range and below saturation. Optical transfer function f (cycles/milliradian) at input of biocular 0.06 0.13 0.27 0.36 0.41 0.47 0.55 MTF 0.98 0.92 O. 78 0.69 0.64 0.57 0.50 3.7.4 Apparent angular magnlfication. The ratio of the image angu
17、lar subtense to the corresponding object angular subtense shall not be less than 1.05 times, when viewed through the biocular eyepiece. 3.7.5 Spatial uniformity. The variance in spatial uniformity of the commanders display shall not exceed +10 percent in the horizontal or - vertical directions over
18、the entire dzsplay. 3.7.6 Effective focal length (EFL). The effective fqcal length of the relay system, measured without the image intensifier (I ) assembly shall be -62, - +3 mm. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-47380 58 77777
19、06 0263587 4 I MIL-C-49 380 (ER) 3.7.7 f/number. The f/number shall be f/5.6. 3.7.8 Gain. The commanders display shall have a minimum luminance gain of 20. 3.7.9 Resolution. The visual axial resolution of the commanders display shall be not less than 20 line pairs per millimeter. 3.7.10 Controls. 3.
20、7.10.1 Contrast. A single control shall be provided to simultaneously control the gain of all channels to provide a minimum of 24 dB of attenuation. 3.7.10.2 Polarity switch. A polarity switch shall be provided to reverse the image contrast and cause the display to represent hot or cold targets as e
21、ither bright or dark. the contrast or brightness controls. Switching polarity shall not require an adjustment of 3.7.10.3 Brightness. A control shall be provided for setting the back- ground level of the image. 3.7.10.4 Commander and gunner. A control shall be provided for the comman- der that will
22、activate either the commanders or the gunners brightness, con- trast, and polarity controls. 1 3.7.11 Sealing, The commanders display shall show no evidence of leakage in excess of 0.2 psig when subjected to an internal pressure of 5, 51 psig for a minimum of 2 hours. The interior atmosphere of the
23、units shall contain dry nitrogen (having a maximum dew point of -32 C at atmospheric pressure), at a pressure of 0.25 to 5.0 psig when delivered. O 3.8 Environment. 3.8.1 Low temperature. 3.8.1.1 Operation. The commanders display shall not be damaged (see 6;3) when operated at temperatures to -32OC.
24、 3.8.1.2 Storage. The commanders dis lay shall not be damaged when sub- g jected to storage at temperatures to -57 C. 3.8.2 High temperature. 3.8.2.1 Operation. The commanders display shall not be damaged when operated at temperatures to +52OC. 3.8.2.2 Storage. The commgnders display shall not be da
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILC493801980COMMANDER SDISPLAYFORANVSG2ANVSG2 指挥官 显示器 PDF

链接地址:http://www.mydoc123.com/p-441689.html