ARMY A-A-52447 A-2009 PUMP FUEL CAM-ACTUATED ENGINE MECHANICAL DIAPHRAGM AND PARTS KIT ENGINE FUEL PUMP [Replaced ARMY MIL-P-45361 B CANC NOTICE 1 ARMY MIL-P-45361 B ARMY MIL-P-453.pdf
《ARMY A-A-52447 A-2009 PUMP FUEL CAM-ACTUATED ENGINE MECHANICAL DIAPHRAGM AND PARTS KIT ENGINE FUEL PUMP [Replaced ARMY MIL-P-45361 B CANC NOTICE 1 ARMY MIL-P-45361 B ARMY MIL-P-453.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-52447 A-2009 PUMP FUEL CAM-ACTUATED ENGINE MECHANICAL DIAPHRAGM AND PARTS KIT ENGINE FUEL PUMP [Replaced ARMY MIL-P-45361 B CANC NOTICE 1 ARMY MIL-P-45361 B ARMY MIL-P-453.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to U.S. Army Tank-automotive and Armaments Command, ATTN: RDTA-EN/DM/STND/TRANS, MS# 268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact information can change, you m
2、ay want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 2910 INCH-POUND A-A-52447A December 14, 2009 SUPERSEDING A-A-52447 15 April 1993 COMMERCIAL ITEM DESCRIPTION PUMP, FUEL, CAM-ACTUATED: ENGINE, MECHANICAL DIAPHRAGM A
3、ND PARTS KIT, ENGINE FUEL PUMP The General Services Administration has authorized the use of this commercial item description as a replacement for MIL-P-45361B. 1. SCOPE This commercial item description (CID) covers requirements for mechanical fuel pumps of the cam-actuated, diaphragm type used on c
4、arburetor-fed internal combustion engines. The rated flow of the fuel pumps ranges from 10 to 50 gallons per hour (gph). Requirements for repair kite to rebuild the fuel pumps are also covered. 2. SALIENT CHARACTERISTICS 2.1 Materials. Unless otherwise specified in the applicable engineering drawing
5、 (AED), the materials used shall be in accordance with the manufacturers specifications. The use of recovered materials in compliance with regulatory requirements is acceptable provided that all the requirements of this CID are met (see 5.1, note a). 2.2 Design and construction. The design and-const
6、ruction of the fuel pump shall be in accordance with the AED (see 5.1, note b). Requirements not specified in the AED shall be in accordance with the manufacturers specifications/drawings. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52447A 2
7、2.3 Repair parts kit. When specified (see 5.1, note c), the repair parts kit for the applicable fuel pump shall be comprised of the items listed either in the kit AED or in accordance with the manufacturers kit specification. The repair kit, including instructions, shall be complete and adequate as
8、required to rebuild and restore the fuel pumps performance as specified herein. The kit items shall not require hand fitting or machining for assembly into the fuel pump. 2.4 Performance. The fuel pump shall be capable of meeting all performance requirements when operated under conditions simulating
9、 intended use and installation on the vehicle. When specified (see 5.1, note d), the manufacturers test procedures may be substituted for any of the verification procedures specified herein. 2.4.1 Shut off pressure. Unless otherwise specified in the AED, the fuel pumps shut off pressure shall be in
10、accordance with the manufacturers specification. The shut off pressure shall be verified by operating the fuel pump at any speed from 200 to 1800 cycles per minute (cpm) with no flow restriction for one minute. The flow shall then be restricted to zero for at least one minute and the shut off pressu
11、re verified at the fuel pump outlet. 2.4.2 Rated flow. The fuel pumps rated flow, in gph, at the indicated outlet pressures shall be as specified in table I. The rated flow shall be verified by operating the fuel pump at a speed of 1800 cpm for five minutes at each of the specified outlet pressures.
12、 TABLE I. Flow rates. Outlet pressure (percent of shut off pressure) Percent rated flow 25 200 50 150 75 100 2.4.3 Endurance and vibration. The fuel pump shall be without failure for at least 500 hours while being subjected capable of operation to vibration resistance. This shall be verified while t
13、he fuel pump is mounted at an angle of 30 degrees to the right or left of the normal vertical operating position, as viewed in the cam shaft axial direction. The vibration produced shall be a simple harmonic motion having an amplitude of 0.03 inch (0.06 inch maximum total excursion). The frequency s
14、hall be varied uniformly from 10 to 55 Hertz (Hz) and back to 10 Hz in about 1 minute. The endurance/vibration cycle shall be as specified in table II. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52447A 3 TABLE II. Endurance test factors. Tes
15、t Hours Pump position Rated flow (percent) Outlet pressure (percent minimum shut off pressure) 30 degrees right Vertical 30 degrees left 95 X 10 1 X 75 95 X 20 1 X 75 95 X 30 1 X 75 95 X 40 1 X 75 95 X 50 1 X 75 6 X 75 6 X 75 2.4.4 Leakage. The fuel pump shall be capable of withstanding an internal
16、air pressure of 10 pounds per square inch (psi) without any damage or leakage. This shall be verified by submerging the fuel section in water and the outlet port plugged. 2.4.5 High temperature. The fuel pump shall meet the performance requirements of d.1 through d.4 while operating in an ambient te
17、mperature of 160 degrees Fahrenheit (F). This shall be verified by filling the fuel pump with a high flash point (140F) mineral/petroleum type spirits solvent degreaser and conditioned for not less than 4 hours in an ambient temperature of 160F prior to operation. The fuel pumps flow rate (see d.2)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52447A2009PUMPFUELCAMACTUATEDENGINEMECHANICALDIAPHRAGMANDPARTSKITENGINEFUELPUMPREPLACEDARMYMILP45361BCANCNOTICE1ARMYMILP45361BARMYMILP453PDF

链接地址:http://www.mydoc123.com/p-439977.html