UL 310-2014 UL Standard for Safety Electrical Quick-Connect Terminals (Ninth Edition)《电气快速连接端子的UL安全标准 (第九版)》.pdf
《UL 310-2014 UL Standard for Safety Electrical Quick-Connect Terminals (Ninth Edition)《电气快速连接端子的UL安全标准 (第九版)》.pdf》由会员分享,可在线阅读,更多相关《UL 310-2014 UL Standard for Safety Electrical Quick-Connect Terminals (Ninth Edition)《电气快速连接端子的UL安全标准 (第九版)》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 310 Electrical Quick-Connect TerminalsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
2、THER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Electrical Quick-Connect Terminals, UL 310 Ninth Edition, Dated Summary of Topics This Ninth Edition of the Standard for Safety for Electrical Quick-Connect Terminals, UL 310, includes the following major changes
3、: Crimp Pull Out Test Method; Clarication of Construction; Inclusion of 24 - 26 AWG Wire Sizes; Deletion of E2 Dimension for Positioning of Detent; Use of Other Platings and Materials; Temperature and Current Cycling Test for Multiple Conductors; and additional miscellaneous changes. The new require
4、ments are substantially in accordance with Proposal(s) on this subject dated January 24, 2014 and June 13, 2014. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording,
5、or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequ
6、ential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liab
7、ility for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including r
8、easonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Stan
9、dard having future effective dates as indicated in the preface. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. OCTOBER 17, 2014 UL 310 tr1UL COPYRIGHTED MATERIAL NOT AU
10、THORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 17, 2014 UL 310 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CSA Group CSA-C22.2 No. 15314 Third Edition Underwriters Laboratorie
11、s Inc. UL 310 Ninth Edition Electrical Quick-Connect Terminals October 17, 2014 ANSI/UL 310-2014UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Canadian Standards Association (
12、operating as “CSA Group”) and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to CSA Group or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of CSA G
13、roup and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ISBN 978-1-771394536 2014 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior pe
14、rmission of the publisher. This Standard is subject to periodic review, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquirescsagroup.org and include “Proposal for change” in the subject l
15、ine: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Standards and related publications, visit CSA Groups Online Store at www.ShopCSA.ca or call toll-free 1-800-463-6727 or 416-747-4044. Co
16、pyright 2014 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive
17、property of UL. This ANSI/UL Standard for Safety consists of the Ninth Edition. The most recent designation of ANSI/UL 310 as an American National Standard (ANSI) occurred on October 15, 2014. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back
18、), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. To purchase UL Standards, visit Comm 2000 at http:/m
19、- or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface .4 1 Scope .6 2 Denitions 6 3 Units of measurement .7 4 Normative references 7 5 Construction 8 5.1 General .8 5.2 Materials 8 5.3 Dimensions
20、 9 5.4 Insulation .10 6 Tests .10 6.1 General 10 6.2 Preparation of specimens 11 6.3 Crimp pull-out test .12 6.4 Insertion-withdrawal test 12 6.5 Temperature and current cycling tests .13 6.6 Dielectric withstand tests .14 6.7 Secureness of insulation test .15 7 Markings 16 8 Installation instructio
21、ns .17 18 25 ANNEX A (Informative) MILLIVOLT DROP TEST A1 General .31 A2 Millivolt drop measurement 31 OCTOBER 17, 2014 CSA-C22.2 NO. 15314 UL 310 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface This is the harmonized CSA Group and
22、UL standard for Electrical Quick-Connect Terminals. It is the Third edition of CSA-C22.2 No. 153 and the Ninth edition of UL 310. This edition of CSA C22.2 No. 153 supersedes the previous edition published in 2009. This edition of UL 310 supersedes the previous edition published May 27, 2009. This h
23、armonized standard was prepared by the CSA Group and Underwriters Laboratories Inc. (UL). The efforts and support of the CANENA Technical Harmonization Subcommittee 99, Electrical Quick-Connect Terminals, are gratefully acknowledged. This Standard is considered suitable for use for conformity assess
24、ment within the stated scope of the Standard. This Standard was reviewed by the CSA Integrated Committee on Electrical Connectors, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL3102014ULSTANDARDFORSAFETYELECTRICALQUICKCONNECTTERMINALSNINTHEDITION 电气 快速 连接 端子 UL 安全标准 第九 PDF

链接地址:http://www.mydoc123.com/p-1068061.html