UL 2034 CRD-2014 UL Standard for Safety Single and Multiple Station Carbon Monoxide Alarms - Section Paragraph Reference Align the Drop Test requirements with the requirements spe.pdf
《UL 2034 CRD-2014 UL Standard for Safety Single and Multiple Station Carbon Monoxide Alarms - Section Paragraph Reference Align the Drop Test requirements with the requirements spe.pdf》由会员分享,可在线阅读,更多相关《UL 2034 CRD-2014 UL Standard for Safety Single and Multiple Station Carbon Monoxide Alarms - Section Paragraph Reference Align the Drop Test requirements with the requirements spe.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): CZHF, JMAE, CZHF2Standard Number: UL 2034Standard Title: Standard for Single and Multiple Station Carbon Monoxide AlarmsEdition Date: February 28, 2008Editio
3、n Number: 33.26 (New), 3.27 (New), 69 (Revised)Section / Paragraph Reference: Align the Drop Test requirements with therequirements specified in UL 2075.Subject:DECISION:New Section 3.263.26 Tabletop Alarm or Accessory An alarm or accessory intended for resting on a horizontal surface,such as a tabl
4、e or nightstand.New Section 3.273.27 Portable Alarm or Accessory An alarm or accessory intended for transient use, such as a travel orpersonal alarm.Revised Section 69.69 Drop Test69.1 This test is to be conducted only on portable or tabletop alarms or accessories intended for transientuse, such as
5、a travel alarm, and is not to be conducted on alarms intended for stationary installation.69.2 An portable alarm or accessory shall withstand five drops from a height of 7 feet (2.1 m) onto a tiledconcrete floor without exposure of internal hazardous-voltage parts or affecting its intended operation
6、 andsensitivity. The sample is to be held so that each impact with the floor is at a different location on thealarm. Parts shall not become dislodged unless the dislodged part does not affect operation or sensitivityof the unit, the dislodged part is replaceable (such as a cover), there are no hazar
7、dous-voltage partsexposed, and the condition is visually obvious.69.3 A tabletop alarm or accessory shall be dropped from the maximum height limit specified in the usersmanual. At a minimum the unit shall be dropped from a height of 3.28 feet (1 meter).69.3 69.4 Each of two alarms is to be raised to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL2034CRD2014ULSTANDARDFORSAFETYSINGLEANDMULTIPLESTATIONCARBONMONOXIDEALARMSSECTIONPARAGRAPHREFERENCEALIGNTHEDROPTESTREQUIREMENTSWITHTHEREQUIREMENTSSPEPDF

链接地址:http://www.mydoc123.com/p-1067776.html