UL 203-2015 UL Standard for Safety Pipe Hanger Equipment for Fire Protection Service (Tenth Edition)《UL消防设施用管道悬挂设备安全标准(第10版)》.pdf
《UL 203-2015 UL Standard for Safety Pipe Hanger Equipment for Fire Protection Service (Tenth Edition)《UL消防设施用管道悬挂设备安全标准(第10版)》.pdf》由会员分享,可在线阅读,更多相关《UL 203-2015 UL Standard for Safety Pipe Hanger Equipment for Fire Protection Service (Tenth Edition)《UL消防设施用管道悬挂设备安全标准(第10版)》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 203 Pipe Hanger Equipment for Fire Protection ServiceUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUT
2、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Pipe Hanger Equipment for Fire Protection Service, UL 203 Tenth Edition, Dated February 3, 2015 Summary of Topics This new edition of ANSI/UL 203 was issued to incorporate the following changes in
3、requirements: 1. Clarication of Requirements for Brackets in Paragraphs 6.2 and 6.3; Clarication of Requirements for Pipe Hangers in Paragraph 6.7; and Clarication of Requirements for the Installation of Hangers in Paragraph 16.2 The new and revised requirements are substantially in accordance with
4、Proposal(s) on this subject dated September 26, 2014. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides th
5、is Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prot
6、s, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this St
7、andard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or devia
8、tion introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note
9、 following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. FEBRUARY 3, 2015 UL 203 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION
10、OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 3, 2015 UL 203 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 3, 2015 1 UL 203 Standard for Pipe Hanger Equipment for Fire Protection Service The First and
11、 Second editions were titled Standard for Pipe Hanger Equipment . First Edition January, 1958 Second Edition June, 1963 Third Edition May, 1966 Fourth Edition October, 1971 Fifth Edition September, 1977 Sixth Edition March, 1985 Seventh Edition October, 1989 Eighth Edition October, 1996 Ninth Editio
12、n January, 2005 Tenth Edition February 3, 2015 This ANSI/UL Standard for Safety consists of the Tenth Edition. The most recent designation of ANSI/UL 203 as an American National Standard (ANSI) occurred on February 3, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pa
13、ges, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safet
14、y are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/
15、UL 203-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 3, 2015 PIPE HANGER EQUIPMENT FOR FIRE PROTECTION SERVICE - UL 203 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITH
16、OUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Components 4 3 Units of Measurement .5 4 Undated References 5 5 Glossary .5 CONSTRUCTION 6 General 8 7 Materials .9 8 Protective Coatings .9 9 Use in Environmental Air Handling Spaces 10 10 Retaining Straps 10 PERFORMANCE 11 Metallic Coating
17、Thickness Test 10 12 Pull Test .12 12.1 General .12 12.2 Concrete inserts 14 12.3 Expansion shells .15 12.4 Fasteners (including powder-driven) 15 12.5 Welding studs .15 12.6 C clamps 16 13 Vibration Test 16 14 Upward Thrust Test .16 MARKINGS 15 General 17 INSTRUCTIONS 16 Installation Instructions 1
18、7 FEBRUARY 3, 2015 PIPE HANGER EQUIPMENT FOR FIRE PROTECTION SERVICE - UL 203 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover the performance of pipe hanger equipment for use in supporting p
19、iping employed in sprinkler systems, water-spray systems, and other piping systems used for re-protection service. 1.2 Requirements for the installation of pipe hangers and auxiliary equipment and limitations for use of specic sizes of hangers and pipe are included in the Standard for the Installati
20、on of Sprinkler Systems, NFPA 13, and the Standard for Water-Spray Fixed Systems for Fire Protection, NFPA 15. 1.3 These requirements cover design variations of hangers dened in Section 5, and do not cover products fabricated from rods of iron or steel with diameters specied by the Standard for the
21、Installation of Sprinkler Systems, NFPA 13, such as U-type hangers, hanger rods, coach screws, and similar products. 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. 2.2 A component is not required t
22、o comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established fo
23、r the intended conditions of use. 2.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those
24、 specic conditions. FEBRUARY 3, 2015 PIPE HANGER EQUIPMENT FOR FIRE PROTECTION SERVICE - UL 203 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 Units of Measurement 3.1 Values stated without parentheses are the requirement. Values in pare
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL2032015ULSTANDARDFORSAFETYPIPEHANGEREQUIPMENTFORFIREPROTECTIONSERVICETENTHEDITIONUL 消防 施用 管道 悬挂 设备

链接地址:http://www.mydoc123.com/p-1067775.html