1、*USACE / NAVFAC / AFCESA / NASA UFGS-03 41 16.08 (August 2012)-Preparing Activity: NASA SupersedingUFGS-03 41 16 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2012*SECTION TABLE OF CONTENTSDIVISION 03 - CONCRETESECTION 03 41 16.08PRECAST CONCR
2、ETE SLABS (MAX. SPAN 8- 0“ O.C.)08/12PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALSPART 2 PRODUCTS2.1 SYSTEM DESCRIPTION2.2 COMPONENTS2.2.1 Clips and Nails2.2.2 Threaded Fasteners2.3 MATERIALS2.3.1 Precast Concrete Roof Slabs2.3.2 Precast Curb Units2.3.3 Cement Grout Joint Sealing Materials2.3.4 Bitumin
3、ous Joint Sealing Materials2.3.5 Packaged Concrete Materials2.3.6 Water For Mixing Cement Grout And Concrete2.3.7 Concrete Curing MaterialsPART 3 EXECUTION3.1 PREPARATION3.1.1 Concrete Roof Slab Placement3.2 INSTALLATION3.2.1 Fastening Roof Slabs3.2.2 Cutting And Fitting3.2.3 Sealing Joints3.2.4 Ins
4、tallation Of Precast Curb Units3.2.5 Fill For Sloping Surfaces3.3 COLD-WEATHER LIMITATIONS3.4 ADJUSTING AND CLEANING3.5 PROTECTION- End of Section Table of Contents -SECTION 03 41 16.08 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / N
5、AVFAC / AFCESA / NASA UFGS-03 41 16.08 (August 2012)-Preparing Activity: NASA SupersedingUFGS-03 41 16 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2012*SECTION 03 41 16.08PRECAST CONCRETE SLABS (MAX. SPAN 8- 0“ O.C.)08/12*NOTE: This guide sp
6、ecification covers the requirements for flat-shaped or channel-shaped roof slabs, max. span 8-0“ o.c. placed over purlins or joists spaced not more than 2.5 meter 8 feet on center that receive insulation board and built-up roofing.Include on the drawings, the following:Complete design indicating the
7、 character of the work to be performed and giving the roof framing, type, and sizes of purlins or joists, thrust angles at walls, bearing angles at ridges for sloping roofs, end bearing plates, dimensions of roof slab units, details of precast cant units, details of cast-in-place concrete cants and
8、other sloping surfaces, details of openings, and sufficient dimensions to convey adequately the quantity and nature of the required roof decking.Assumed loads and other design data as may be required for the proper preparation of shop drawings.Precast concrete slabs for clear spans exceeding 2.5 met
9、er 8 feet are specified in Section 03 41 33 PRECAST STRUCTURAL PRETENSIONED CONCRETE.A structural steel roof framing system, including steel purlins and framing for openings larger than 1/2 width of roof slabs in any dimension, is specified in Section 05 12 00 STRUCTURAL STEEL.An open-web steel jois
10、t roof framing system is specified in Section 05 21 19 OPEN WEB STEEL JOIST FRAMING.Fire resistance-rated roof and ceiling constructions using precast concrete roof decking are described in Underwriters Laboratories, Inc., “Fire Resistance Ratings (BXUV)“ contained in UL FRD and the “Fire Resistance
11、 Ratings“ contained in AIA CO-1. Fire SECTION 03 41 16.08 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-resistance rated construction limits the type and spacing of the roof framing system; type of roof slab units and method of fastening the
12、roof slabs to the supporting frame; ceiling construction; and roof construction.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project speci
13、fic requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this
14、 guide specification are welcome and should be submitted as a Criteria Change Request (CCR)*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and list
15、ed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to u
16、pdate the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publi
17、cations are referred to within the text by the basic designation only.AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO)AASHTO M 182 (2005; R 2009) Standard Specification for Burlap Cloth Made from Jute or Kenaf and Cotton MatsSECTION 03 41 16.08 Page 3Provided by IHSNot for
18、 ResaleNo reproduction or networking permitted without license from IHS-,-,-AMERICAN CONCRETE INSTITUTE INTERNATIONAL (ACI)ACI C-21 (1992) Elevated SlabsAMERICAN WOOD PROTECTION ASSOCIATION (AWPA)AWPA BOOK (2012) AWPA Book of StandardsASME INTERNATIONAL (ASME)ASME B18.2.2 (2010) Standard for Square
19、and Hex NutsASME B18.2.6 (2010) Fasteners for Use in Structural ApplicationsASME B18.21.1 (2009) Washers: Helical Spring-Lock, Tooth Lock, and Plain Washers (Inch Series)ASME B18.22M (1981; R 2010) Metric Plain WashersASME B18.6.3 (2010) Machine Screws, Tapping Screws, and Machine Drive Screws (Inch
20、 Series)ASME B18.6.7M (1999; R 2010) Metric Machine ScrewsASTM INTERNATIONAL (ASTM)ASTM C150/C150M (2011) Standard Specification for Portland CementASTM C171 (2007) Standard Specification for Sheet Materials for Curing ConcreteASTM C33/C33M (2011a) Standard Specification for Concrete AggregatesASTM
21、C387/C387M (2011b) Standard Specification for Packaged, Dry, Combined Materials for Mortar and ConcreteASTM C514 (2004; R 2009e1) Standard Specification for Nails for the Application of Gypsum BoardASTM C595/C595M (2011) Standard Specification for Blended Hydraulic CementsASTM C618 (2012) Standard S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS034116082012PRECASTCONCRETESLABSMAXSPAN80OCPDF

链接地址:http://www.mydoc123.com/p-1019625.html