NF L53-201-059-2008 Aerospace series - Electrical contacts used in elements of connection - Part 059 contacts electrical coaxial size 16 female type D solder class R - Product sta.pdf
《NF L53-201-059-2008 Aerospace series - Electrical contacts used in elements of connection - Part 059 contacts electrical coaxial size 16 female type D solder class R - Product sta.pdf》由会员分享,可在线阅读,更多相关《NF L53-201-059-2008 Aerospace series - Electrical contacts used in elements of connection - Part 059 contacts electrical coaxial size 16 female type D solder class R - Product sta.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、NF EN 3155-059janvier 2008Ce document est usage exclusif et non collectif des clients Saga Web.Toute mise en rseau, reproduction et rediffusion, sous quelque forme que ce soit,mme partielle, sont strictement interdites.This document is intended for the exclusive and non collective use of Saga Web cu
2、stomers.All network exploitation, reproduction and re-dissemination,even partial, whatever the form (hardcopy or other media), is strictly prohibited.Saga Web Pour SHANGHAI INTERNAT SCIENCE slip a dielectric barrier between the shield braid and the cable dielectric to bring the diameter within the v
3、alue specified in Table 1. EN 3155-059:2006 (F) 8Figure 2 4.6.2.2 Prparation dun cble pour blindage repli Le diamtre du blindage est infrieur B min. du Tableau 1. Restriction: si le diamtre du blindage devient B max. (2,13 mm). Lgende 1 Blindage repli sur la gaine du cble Figure 3 4.6.2.3 Prparation
4、 dun cble coaxial de faible diamtre dilectrique Le diamtre dilectrique C min. Tableau 1 (0,91 mm) : dnuder le cble comme indiqu dans la Figure 4 ; introduire une barrire dilectrique entre la tresse de la gaine et le cble dilectrique pour ramener le diamtre la valeur spcifie dans le Tableau 1. EN 315
5、5-059:2006 (E) 9Key 1 Dielectric barrier Figure 4 4.7 Tooling 4.7.1 Contact termination tooling The hot air generator shall have a minimum usable capacity of 800 W and the temperature in the heating zone shall be (420 20) C. The drawing of the tool is given for information purposes: the positioner h
6、as an interface for the male contact on side P and the female contact on side S (see Figure 5); the function of the cable clamp is to hold the parts in place during the heating and cooling phases. Key 1 Coaxial cable 4 Cable clamp 2 Contact 5 Positioning device Figure 5 4.7.2 Insertion/extraction to
7、oling Insertion: MIL-I-81969/14-03 or MIL-I-81969/08-07 Extraction: MIL-I-81969/14-03 or MIL-I-81969/08-08 EN 3155-059:2006 (F) 9Lgende 1 Barrire dilectrique Figure 4 4.7 Outillage 4.7.1 Outillage dextrmit de contact Le gnrateur dair chaud a une capacit minimale de fonctionnement de 800 W et la temp
8、rature dans la zone chauffe doit tre de (420 20) C. Le dessin de loutil est donn titre dinformation : le systme de positionnement a une interface pour le contact mle sur le ct P et pour le contact femelle sur le ct S (voir Figure 5) ; la bride du cble a pour fonction de maintenir les pices en place
9、au cours des phases de chauffage et de refroidissement. Lgendes 1 Cble coaxial 4 Bride du cble 2 Contact 5 Systme de positionnement Figure 5 4.7.2 Outillage dinsertion/dextractionInsertion: MIL-I-81969/14-03 ou MIL-I-81969/08-07 Extraction: MIL-I-81969/14-03 ou MIL-I-81969/08-08 EN 3155-059:2006 (E)
10、 104.8 Tests See Table 2. Table 2 Applicable EN 2591- Test Notapplicable According to EN 3155-001 Remarks 101 Visual examination X 102 Examination of dimensions and mass X See 4.2. 201 Contact resistance - Low level X Test temperature: ambient Maximum contact resistancemContactInitial After tests Ce
11、ntre 10 15 Outer Not applicable 202 Contact resistance at rated current X Maximum contact resistance m(25 03 ) C (150 03 ) C ContactInitial Aftertests After tests RatedcurrentACentre 10 15 20 1 Outer 1,5 2 3 7,5 204 Discontinuity of contacts in the microsecond range X Method B Duration of discontinu
12、ity: 100 ns Test duration: throughout the duration of tests 402 and 403. 206 Measurement of insulation resistance X Method C Mated contacts At ambient 5 GAt 150 C 2 G207 Voltage proof test X Method C Proof test voltage at sea level:500 V r.m.s. between centre contact and outer contact.Proof test vol
13、tage at altitude:125 V r.m.s. at 1,1 kPa pressure (33 000 m). Leakage current: 2 mA EN 3155-059:2006 (F) 104.8 Essais Voir Tableau 2. Tableau 2 Applicable EN 2591- Essai Nonapplicable Selon lEN 3155-001 Remarques 101 Examen visuel X 102 Examen des dimensions et masse X Voir 4.2. 201 Rsistance de con
14、tact sous faible intnsit X Essai en temprature : ambiante Rsistance maximale du contact mContactInitial Aprs essai Central 10 15 Extrieur Non applicable 202 Rsistance de contact au courant nominal X Rsistance maximale du contactm(25 03 ) C (150 03 ) C ContactInitial Aprsessai Aprs essai Courantnomin
15、alACentral 10 15 20 1 Extrieur 1,5 2 3 7,5 204 Discontinuit des contacts dans la gamme des microsecondes X Mthode B Dure de discontinuit : 100 ns Dure de lessai: Pendant toute la dure des essais EN 2591-402 et EN 2591-403. 206 Mesure de la rsistance disolement X Mthode C Contacts accoupls la temprat
16、ure ambiante 5 G 150 C 2 G207 Essai de tenue en tension X Mthode C Essai de tenue en tension au niveau de la mer : 500 V r.m.s. entre le contact central et le contact extrieur. Essai de tenue en tension en altitude : 125 V r.m.s. avec une pression de 1,1 kPa (33 000 m). Courant de fuite : 2 mA EN 31
17、55-059:2006 (E) 11Table 2 (continued) Applicable EN 2591- Test Notapplicable According toEN 3155-001 Remarks 210 Electrical overload X 211 Capacitance measurement X 212 Surface transfer impedance X 213 Shielding effectiveness from 100 MHz to 1 GHz X301 Endurance at temperature X Method B 150 C Durat
18、ion: 1 000 h 305 Rapid change of temperature X TA ( 65 2) C TB (150 2) C306 Mould growth X 307 Salt mist X 315 Fluid resistance X See Table 3. 402 Shock X Method A, severity 300. The contacts shall be connected with a cable as per Table 1, then fitted in connectors. The connectors fitted with approp
19、riate cable clamps shall be mated and mounted on the shock apparatus using appropriate mounting systems. Discontinuity: 100 ns 403 Sinusoidal and random vibrations X The contacts shall be connectedto a cable as per Table 1 then fitted in the connectors. The connectors fitted with appropriate cable c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFL532010592008AEROSPACESERIESELECTRICALCONTACTSUSEDINELEMENTSOFCONNECTIONPART059CONTACTSELECTRICALCOAXIALSIZE16FEMALETYPEDSOLDERCLASSRPRODUCTSTAPDF

链接地址:http://www.mydoc123.com/p-1003168.html