EN ISO 13517-2013 en Metallic powders - Determination of flowrate by means of a calibrated funnel (Gustavsson flowmeter)《金属粉末 利用带刻度漏斗进行流速测定》.pdf
《EN ISO 13517-2013 en Metallic powders - Determination of flowrate by means of a calibrated funnel (Gustavsson flowmeter)《金属粉末 利用带刻度漏斗进行流速测定》.pdf》由会员分享,可在线阅读,更多相关《EN ISO 13517-2013 en Metallic powders - Determination of flowrate by means of a calibrated funnel (Gustavsson flowmeter)《金属粉末 利用带刻度漏斗进行流速测定》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationMetallic powders Determination of flowrate bymeans of a calibrated funnel(Gustavsson flowmeter)BS EN ISO 13517:2013National forewordThis British Standard is the UK implementation
2、 of EN ISO 13517:2013.The UK participation in its preparation was entrusted to Technical CommitteeISE/65, Sintered metal components.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisio
3、ns of acontract. Users are responsible for its correct application. The British Standards Institution 2013Published by BSI Standards Limited 2013ISBN 978 0 580 70955 5ICS 77.160Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under t
4、he authority of the StandardsPolicy and Strategy Committee on 31 May 2013.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN ISO 13517:2013EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 13517 May 2013 ICS 77.160 English Version Metallic powders - Determinat
5、ion of flowrate by means of a calibrated funnel (Gustavsson flowmeter) (ISO 13517:2013) Poudres mtalliques - Dtermination du temps dcoulement au moyen dun entonnoir calibr (cne dcoulement de Gustavsson) (ISO 13517:2013) Metallpulver - Ermittlung der Durchflussrate mit Hilfe eines kalibrierten Tricht
6、ers (Gustavsson flowmeter) (ISO 13517:2013) This European Standard was approved by CEN on 1 March 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
7、 Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tr
8、anslation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Fin
9、land, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZAT
10、ION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 13517:2013: EBS EN ISO 13517:2013EN ISO 13517:2013 (E)
11、2 Contents Page Foreword 3 BS EN ISO 13517:2013EN ISO 13517:2013 (E) 3 Foreword This document (EN ISO 13517:2013) has been prepared by Technical Committee ISO/TC 119 “Powder metallurgy“. This European Standard shall be given the status of a national standard, either by publication of an identical te
12、xt or by endorsement, at the latest by November 2013, and conflicting national standards shall be withdrawn at the latest by November 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held respo
13、nsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finla
14、nd, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of IS
15、O 13517:2013 has been approved by CEN as EN ISO 13517:2013 without any modification. BS EN ISO 13517:2013ISO 13517:2013(E) ISO 2013 All rights reserved iiiContents Page1 Scope . 12 Principle 13 Apparatus . 14 Calibration of the funnel. 24.1 Calibration by the manufacturer of the funnel 24.2 Calibrat
16、ion by the user of the funnel 35 Sampling 36 Procedure. 37 Expression of results 48 Precision . 49 Test report . 5Bibliography 6BS EN ISO 13517:2013INTERNATIONAL STANDARD ISO 13517:2013(E)Metallic powders Determination of flowrate by means of a calibrated funnel (Gustavsson flowmeter)1 ScopeThis Int
17、ernational Standard specifies a method for determining the flow rate of metallic powders, including powders for hardmetals and mixes of metallic powders and organic additives such as lubricants, by means of a calibrated funnel (Gustavsson flowmeter).The method is applicable only to powders which flo
18、w freely through the specified test orifice.2 PrincipleMeasurement of the time required for 50 g of a metallic powder to flow through the orifice of a calibrated funnel of standardized dimensions.3 Apparatus3.1 Calibrated funnel, with the dimensions shown in Figure 1 (see Clause 4). The dimensions s
19、hown for the flowmeter funnel, including the orifice, are not to be considered controlling factors. Calibration with emery, as specified in Clause 4, determines the working flow rate of the funnel.The funnel shall be made of a non-magnetic, corrosion-resistant metallic material with sufficient wall
20、thickness and hardness to withstand distortion and excessive wear.1)3.2 Stand and horizontal vibration-free base, to support the funnel rigidly, e.g. as indicated in Figure 21).3.3 Balance, of sufficient capacity, capable of weighing the test portion to an accuracy of 0,05 g.3.4 Stopwatch, capable o
21、f measuring the elapsed time to an accuracy of 0,1 s.3.5 Chinese emery grit, a reference powder used for calibration of the funnel.1)1) Apparatus complying with 3.1 and 3.2, and standard Chinese emery grit can be purchased from ACuPowder International, LLC, 901 Lehigh Avenue, Union, NJ 07083, USA. T
22、his information is given for the convenience of users of this International Standard and does not constitute an endorsement by ISO of the company named above. Equivalent products may be used if they can be shown to lead to the same results. ISO 2013 All rights reserved 1BS EN ISO 13517:2013ISO 13517
23、:2013(E)Dimensions in millimetresFigure 1 Calibrated funnel (Gustavsson flowmeter)Figure 2 Arrangement of calibrated funnel and stand4 Calibration of the funnel4.1 Calibration by the manufacturer of the funnelThe manufacturer shall supply the flowmeter calibrated as follows:a) Dry the Chinese emery
24、grit (3.5) in an open and clean glass jar at 110 C for 60 min in air;2 ISO 2013 All rights reservedBS EN ISO 13517:2013ISO 13517:2013(E)b) Cool the emery to room temperature in a desiccator;c) Weigh out 50 g of the emery grit;d) Follow the procedure outlined in Clause 6;e) Repeat the procedure with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISO135172013ENMETALLICPOWDERSDETERMINATIONOFFLOWRATEBYMEANSOFACALIBRATEDFUNNELGUSTAVSSONFLOWMETER 金属粉末

链接地址:http://www.mydoc123.com/p-725013.html