ASTM UOP936-2016 Combined Nitrogen in LPG by Chemiluminescence《利用化学发光法测定液化石油气中的化合态氮》.pdf
《ASTM UOP936-2016 Combined Nitrogen in LPG by Chemiluminescence《利用化学发光法测定液化石油气中的化合态氮》.pdf》由会员分享,可在线阅读,更多相关《ASTM UOP936-2016 Combined Nitrogen in LPG by Chemiluminescence《利用化学发光法测定液化石油气中的化合态氮》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. SAFETY DATA SHEETS (SDS) OR EXPERIMENTAL SAFETY DATA SHEETS (ESDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1995, 2016 UOP LLC. All rights reserved. Nonconfidential U
3、OP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.832.9585 PHONE. Combin
4、ed Nitrogen in LPG by Chemiluminescence UOP Method 936-16 Scope This method is for determining combined nitrogen in liquefied petroleum gas (LPG). The method determines all nitrogen compounds that are extractable by aqueous acid, including ammonia, amines, nitriles and amides. The method is particul
5、arly useful for LPG samples containing nitrogen species, such as ammonia and amines, which can readily adsorb on stainless steel surfaces in contact with the LPG. The procedure yields quantitative results in the range of 0.2 mass-ppm (mg/kg) to 3 mass%. The method is also used as a preparation step
6、for the analysis of basic nitrogen in LPG by UOP Method 939, “Basic Nitrogen in LPG by Ion Chromatography.” References ASTM Method D4629, “Trace Nitrogen in Liquid Petroleum Hydrocarbons by Syringe/Inlet Oxidative Combustion and Chemiluminescence Detection,” www.astm.org UOP Method 516, “Sampling of
7、 Gasolines, Distillate Fuels and C2-C4 Fractions,” www.astm.org UOP Method 939, “Basic Nitrogen in LPG by Ion Chromatography,” www.astm.org UOP Method 981 “Trace Nitrogen in Liquid Hydrocarbons by Oxidative Combustion with Chemiluminescence Detection,” www.astm.org UOP Method 999, “Precision Stateme
8、nts in UOP Methods,” www.astm.org Outline of Method Nitrogen compounds are quantitatively extracted from an LPG sample using a solution of 2N acetic acid in water. A measured mass of LPG is transferred to a cleaned, silica coated sample extraction cylinder. A known amount of acid solution is added t
9、o a second cylinder, the two vessels are connected and the acid solution is transferred under helium pressure into the sample extraction cylinder. The nitrogen components are extracted into the acid solution by mixing the liquids for several minutes. The LPG and acid extract are allowed to separate.
10、 The acid extract is withdrawn and analyzed for total nitrogen by chemiluminescence, utilizing ASTM Method D4629, “Trace Nitrogen in Liquid Petroleum Hydrocarbons by Syringe/Inlet Oxidative Combustion and Chemiluminescence Detection”. Apparatus References to catalog numbers and suppliers are include
11、d as a convenience to the method user. Other suppliers may be used. 2 of 14 936-16 Adapter, male, 2 required, for charging the acetic acid cylinder, Swagelok, Cat. No. SS-4-TA-1-4 (see also Connector) Balance, readability 0.001 g Balance, readability 0.1 g, capacity 4000 g Beaker, polypropylene, 100
12、-mL, Fisher Scientific, Cat. No. 02-591-27 Clamps, for ring stand and sample cylinders, several required, with holders and cast iron ring, Fisher Scientific, Cat. Nos. 05-769-8Q, 05-754 and 14-050CQ, respectively Connector, stainless steel, used to connect the 300-mL and the 1000-mL cylinders vertic
13、ally together and consisting of a male connector, Swagelok, Cat. No. SS-400-1-4 joined together with one male adapter, Swagelok, Cat. No. SS-4-TA-1-4. Cylinder, collection, for initial sample collection from process stream, stainless steel, Sulfinert coated, 1000-mL, with valve and valve with outage
14、 tube, Restek, Cat. Nos. 24134, 21400, and 21402-038, respectively. Cylinder, extraction, type 304 stainless steel, high pressure, 12,400 kPa gauge (1800 psi) maximum working pressure, 1000-mL capacity, Swagelok, Cat. Nos. 304L-HDF4-1000. Equip the cylinders with two stainless steel valves each, Swa
15、gelok, Cat. No. SS-16DKM4-F4, and two pipe-plugs each, Cajon, quarter-inch P-male-NPT, Swagelok, Cat. No. SS-4-P. Cylinder, acid injection, type 304 stainless steel, high pressure, 12,400 kPa gauge (1800 psi) maximum working pressure, 300-mL capacity, Swagelok, Cat. Nos. 304L-HDF4-300. Equip the cyl
16、inders with two stainless steel valves each, Swagelok, Cat. No. SS-16DKM4-F4, and two pipe-plugs each, Cajon, quarter-inch P-male-NPT, Swagelok, Cat. No. SS-4-P. Cylinders, graduated, borosilicate glass, 50-, 100- and 250-mL, Fisher Scientific, Cat. Nos. 08-556C, D and E, respectively Extractor (opt
17、ional), special construction, see Appendix Flask, Erlenmeyer, 50-mL, Fisher Scientific, Cat. No. FB-500-50 Flasks, volumetric, 100-, 200-, 1000-, and 2000-mL, with caps, Fisher Scientific, Cat. Nos. 10-210-5C, -5D, -5G, and -5H, respectively. Several of each are required, see Reagents and Materials
18、and Procedure. Gage, pressure, 0-20,000 kPa gage (0-3000 psig), 2-inch diameter, ”-inch MNPT, used for testing the pressure of an unknown LPG sample gas cylinder, Matheson Gas Products, Model 63-2233 Hood, laboratory Nitrogen Chemiluminescence Analyzer, with attached furnace, autosampler, vacuum pum
19、p, controls and computer. This method was developed and validated using the Mitsubishi analyzer NSX-2100V, with ND-210 Nitrogen Detector and STC-210 Sample Temperature Controller. The procedure for analysis may be different for other instruments and all other instruments need to be validated before
20、using for this method. The Mitsubishi analyzer must be equipped with the following accessories: Autosampler, Mitsubishi Model ASC-250L, COSA Xentaur Corporation Autosampler syringes, gas tight, 50-L, Mitsubishi, Cat. No. MC18525, COSA Xentaur Corporation Autosampler vials, rinse, Mitsubishi Cat. No.
21、 TX3LSW, COSA Xentaur Corporation 3 of 14 936-16 Cyclone trap, Cat. No. MC 1914, COSA Xentaur Corporation Membrane drier, Perma Pure MD-110-24F-4 or Mitsubishi Tube Dryer, Cat. No. TN6RPC, COSA Xentaur Corporation (see Note 4) Sample Temperature Controller, Mitsubishi Model STC-210, COSA Xentaur Cor
22、poration Vacuum pump, Vacuubrand MD4CNT and Ulvac GLS-050 vacuum pumps meet this requirement; other vacuum pumps must be evaluated before use, COSA Xentaur Corporation (see Note 3) Oven, drying, capable of maintaining 105C Pipet, Mohr, 1-, 5- and 25-mL, Fisher Scientific, Cat. Nos. 13-665-F, -K and
23、-N, respectively Pipet, volumetric, Class A, 50-mL, 20-mL, 10- mL, 4-mL Fisher Scientific, Cat. No. 13-650-2S, 13-650-2N, 13-650-2L, 13-650-2E, respectively. Pipet filler, Fisher Scientific, Cat. No. 13-681-102A Refrigerator, Fisher Scientific, Cat. No. 14-512-526 Regulators, inert gas, two-stage, M
24、atheson Tri-Gas, Models 3810A-580 (used for the nitrogen analyzer) and 3030-580 (used for acetic acid transfer between cylinders) Regulator, oxygen, two-stage, high purity, Matheson Tri-Gas, Model 3810A-540, cleaned for oxygen service by the supplier, used with Nitrogen Analyzer Ring stand, with rec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMUOP9362016COMBINEDNITROGENINLPGBYCHEMILUMINESCENCE 利用 化学 发光 测定 液化 石油气 中的 化合 PDF

链接地址:http://www.mydoc123.com/p-540832.html