ASTM G69-1997(2003) Standard Test Method for Measurement of Corrosion Potentials of Aluminum Alloys《测定铝合金潜在腐蚀性》.pdf
《ASTM G69-1997(2003) Standard Test Method for Measurement of Corrosion Potentials of Aluminum Alloys《测定铝合金潜在腐蚀性》.pdf》由会员分享,可在线阅读,更多相关《ASTM G69-1997(2003) Standard Test Method for Measurement of Corrosion Potentials of Aluminum Alloys《测定铝合金潜在腐蚀性》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: G 69 97 (Reapproved 2003)Standard Test Method forMeasurement of Corrosion Potentials of Aluminum Alloys1This standard is issued under the fixed designation G 69; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is a procedure for measurement of thecorrosion potential (see Note 1) of an aluminum alloy in an
3、aqueous solution of sodium chloride with enough hydrogenperoxide added to provide an ample supply of cathodicreactant.NOTE 1The corrosion potential is sometimes referred to as theopen-circuit solution or rest potential.1.2 This standard does not purport to address all of thesafety concerns, if any,
4、associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 1193 Specification for Reagent Water23. Significance
5、 and Use3.1 The corrosion potential of an aluminum alloy dependsupon the amounts of certain alloying elements that the alloycontains in solid solution. Copper and zinc, which are two ofthe major alloying elements for aluminum, have the greatesteffect with copper shifting the potential in the noble o
6、r positivedirection, and zinc in the active or negative direction. Forexample, commercially unalloyed aluminum (1100 alloy)3hasa potential of 750 mV when measured in accordance with thispractice, 2024T3 alloy with nearly all of its nominal 4.3 %copper in solid solution, a potential of 600 to 620 mV
7、(Note2), and 7072 alloy with nearly all of its nominal 1.0 % zinc insolid solution, a potential of 885 mV (SCE) (1-3).4NOTE 2The potential depends upon the rate of quenching.3.2 Because it reflects the amount of certain alloying ele-ments in solid solution, the corrosion potential is a useful toolfo
8、r characterizing the metallurgical condition of aluminumalloys, especially those of the 2XXX and 7XXX types, whichcontain copper and zinc as major alloying elements. Its usesinclude the determination of the effectiveness of solution heattreatment and annealing (1), of the extent of precipitationduri
9、ng artificial aging (4) and welding (5), and of the extent ofdiffusion of alloying elements from the core into the claddingof alclad products (2).4. Apparatus4.1 The apparatus consists of an inert container for the testsolution, a mechanical support for the test specimens thatinsulates them electric
10、ally from each other and from ground,saturated calomel electrode (SCE) (see Note 3), wires andaccessories for electrical connections, and equipment for themeasurement of potential.NOTE 3Saturated calomel electrodes are available from severalmanufacturers. It is a good practice to ensure the proper f
11、unctioning of thereference electrode by measuring its potential against one or morereference electrodes. The potential difference should not exceed 2 or 3mV.54.2 A high-impedence (1012V) voltmeter is suitable formeasurement of the potential. Measurement of this potentialshould be carried out to with
12、in 6 1 mV. Automatic datarecording systems may be used to permit the simultaneousmeasurement of many specimens and the continuous recordingof corrosion potentials.5. Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall re
13、agents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.6Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening t
14、heaccuracy of the determination.1This practice is under the jurisdiction of Committee G01 on Corrosion ofMetals and is the direct responsibility of Subcommittee G01.11 on ElectrochemicalMeasurements in Corrosion Testing.Current edition approved Oct. 10, 1997. Published December 1997. Originallyappro
15、ved in 1981. Last previous edition approved in 1994 as G 69 81 (1994)e1.2Annual Book of ASTM Standards, Vol 11.01.3All alloy designations are those of the Aluminum Association.4The boldface numbers in parentheses refer to the references at the end of thisstandard.5Round-robin test conducted by G01.1
16、1 (unpublished results).6Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the
17、United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Purity of WaterThe water shall be distilled or deion-ized conforming to t
18、he purity requirements of SpecificationD 1193, Type IV reagent water.5.3 Sodium Chloride (NaCl).5.4 Hydrogen Peroxide (H2O2) (30 %)In case of uncer-tainty (for example, whenever freshly opened reagent is notused), the concentration of hydrogen peroxide in the reagentshall be confirmed by chemical an
19、alysis as described in AnnexA1. In no case shall reagent containing less than 20 %hydrogen peroxide be used.6. Solution Conditions6.1 The test solution shall consist of 58.5 6 0.1 g of NaCland 9 6 1 mL of 30 % hydrogen peroxide reagent per 1 L ofaqueous solution. (This solution is 1 M with respect t
20、oconcentration of sodium chloride.)6.2 The hydrogen peroxide reagent shall be added justbefore measurements are made because it decomposes uponstanding.6.3 Freshly prepared solution shall be used for each set ofmeasurements.6.4 Not less than 500 mL of solution shall be used for eachset of measuremen
21、ts.6.5 The total exposed area of all the specimens of the samecomposition in each set of measurements shall not exceed 100mm2per 100 mL of solution.6.6 The temperature of the test solution shall be maintainedat 25 6 2C.7. Test Specimen7.1 For measurement alone, specimen size is unimportantprovided t
22、hat the area for measurement is at least 25 mm2, butfor convenience the specimen, wherever possible, should belarge enough to permit ease of handling during preparation andan electrical connection outside the test solution. A specimen afew millimetres thick by about 15 mm wide and 100 mm longis a co
23、nvenient size.8. Specimen Preparation8.1 Any convenient means such as sawing or stamping maybe used to prepare a specimen to size provided that it does notheat the specimen enough to change its metallurgical structure.8.2 Irregular-shaped specimens shall be machined or pre-pared with a coarse file t
24、o provide a reasonably flat surface andto remove nonrepresentative metal (for example, affected bysawing or stamping, or in case of clad product where core is tobe measured). Further preparation consists of filing with a longlathe file. Original flat surface specimens are also filed withlong lathe f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG6919972003STANDARDTESTMETHODFORMEASUREMENTOFCORROSIONPOTENTIALSOFALUMINUMALLOYS 测定 铝合金 潜在 腐蚀性 PDF

链接地址:http://www.mydoc123.com/p-540690.html