《ASTM G106-1989(2010) Standard Practice for Verification of Algorithm and Equipment for Electrochemical Impedance Measurements《电化学阻抗测量用算法和设备的验证标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM G106-1989(2010) Standard Practice for Verification of Algorithm and Equipment for Electrochemical Impedance Measurements《电化学阻抗测量用算法和设备的验证标准实施规程》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: G106 89 (Reapproved 2010)Standard Practice forVerification of Algorithm and Equipment for ElectrochemicalImpedance Measurements1This standard is issued under the fixed designation G106; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers an experimental procedure whichcan be used to check ones instrumentat
3、ion and technique forcollecting and presenting electrochemical impedance data. Iffollowed, this practice provides a standard material, electro-lyte, and procedure for collecting electrochemical impedancedata at the open circuit or corrosion potential that shouldreproduce data determined by others at
4、 different times and indifferent laboratories. This practice may not be appropriate forcollecting impedance information for all materials or in allenvironments.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standar
5、d does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM
6、 Standards:2D1193 Specification for Reagent WaterG3 Practice for Conventions Applicable to ElectrochemicalMeasurements in Corrosion TestingG5 Reference Test Method for Making Potentiostatic andPotentiodynamic Anodic Polarization MeasurementsG15 Terminology Relating to Corrosion and CorrosionTesting3
7、G59 Test Method for Conducting Potentiodynamic Polar-ization Resistance Measurements3. Terminology3.1 DefinitionsFor definitions of corrosion related terms,see Terminology G15.3.2 Symbols:C = capacitance (farad-cm2)E8 = real component of voltage (volts)E9 = imaginary component of voltage (volts)E =
8、complex voltage (volts)f = frequency (s1)I8 = real component of current (amp-cm2)I9 = imaginary component of current (amp-cm2)I = complex current (amp-cm2)j =21L = inductance (henry cm2)Rs= solution resistance (ohm-cm2)Rp= polarization resistance (ohm-cm2)Rt= charge transfer resistance (ohm-cm2)Z8 =
9、 real component of impedance (ohm-cm2)Z9 = imaginary component of impedance (ohm-cm2)Z = complex impedance (ohm-cm2)a = phenomenological coefficients caused by depressionof the Nyquist plot below the real axis, a is theexponent and t is the time constant(s).u = phase angle (deg)v = frequency (radian
10、s-s1)Subscripts:x = in-phase componenty = out-of-phase component4. Summary of Practice4.1 Reference impedance plots in both Nyquist and Bodeformat are included. These reference plots are derived from theresults from nine different laboratories that used a standarddummy cell and followed the standard
11、 procedure using aspecific ferritic type alloy UNS-S430004in 0.005 M H2SO4and 0.495 M Na2SO4. The plots for the reference material arepresented as an envelope that surrounds all of the data with and1This practice is under the jurisdiction of ASTM Committee G01 on Corrosionof Metals and is the direct
12、 responsibility of Subcommittee G01.11 on Electrochemi-cal Measurements in Corrosion Testing.Current edition approved May 1, 2010. Published May 2010. Originallyapproved in 1989. Last previous edition approved in 2004 as G10689(2004). DOI:10.1520/G0106-89R10.2For referenced ASTM standards, visit the
13、 ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4These
14、standard samples are available fromASTM Headquarters. Generally, onesample can be repolished and reused for many runs. This procedure is suggested toconserve the available material.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.with
15、out inclusion of the uncompensated resistance. Plots forone data set from one laboratory are presented as well. Sincethe results from the dummy cell are independent of laboratory,only one set of results is presented.4.2 A discussion of the electrochemical impedance tech-nique, the physics that under
16、lies it, and some methods ofinterpreting the data are given in the Appendix X1-AppendixX6. These sections are included to aid the individual inunderstanding the electrochemical impedance technique andsome of its capabilities. The information is not intended to beall inclusive.5. Significance and Use
17、5.1 The availability of a standard procedure, standard ma-terial, and standard plots should allow the investigator to checkhis laboratory technique. This practice should lead to electro-chemical impedance curves in the literature which can becompared easily and with confidence.5.2 Samples of a stand
18、ard ferritic type 430 stainless steel(UNS 430000) used to obtain the reference plots are availablefor those who wish to check their equipment. Suitable resistorsand capacitors can be obtained from electronics supply houses.5.3 This test method may not be appropriate for electro-chemical impedance me
19、asurements of all materials or in allenvironments.6. Apparatus6.1 Dummy CellThe dummy cell used to check theequipment and method for generating electrochemical imped-ance data is composed of a 10 V precision resistor placed inseries with a circuit element composed of a 100 V precisionresistor in par
20、allel with a 100 F capacitor. The resistors shouldhave a stated precision of 60.1 %. The capacitor can have aprecision of 620 %. The cell can be constructed from readilyavailable circuit elements by following the circuit diagramshown in Fig. 1.6.2 Test CellThe test cell should be constructed to allo
21、wthe following items to be inserted into the solution chamber:the test electrode, two counter electrodes or a symmetricallyarranged counter electrode around the working electrode, aLuggin-Haber capillary with salt bridge connection to thereference electrode, an inlet and an outlet for an inert gas,
22、anda thermometer or thermocouple holder. The test cell must beconstructed of materials that will not corrode, deteriorate, orotherwise contaminate the solution.6.2.1 One type of suitable cell is described in ReferenceTestMethod G5. Cells are not limited to that design. For example,a 1-L round-bottom
23、 flask can be modified for the addition ofvarious necks to permit the introduction of electrodes, gas inletand outlet tubes, and the thermometer holder. A Luggin-Habercapillary probe could be used to separate the bulk solution fromthe saturated calomel electrode. The capillary tip can be easilyadjus
24、ted to bring it into close proximity to the workingelectrode. The minimum distance should be no less than twocapillary diameters from the working electrode.6.3 Electrode HolderThe auxiliary and working elec-trodes can be mounted in the manner shown in Reference TestMethod G5. Precautions described i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG10619892010STANDARDPRACTICEFORVERIFICATIONOFALGORITHMANDEQUIPMENTFORELECTROCHEMICALIMPEDANCEMEASUREMENTS

链接地址:http://www.mydoc123.com/p-540262.html