ASTM F2623-2008 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing《升温的PE-RT材料标准尺寸比(SDR)为9管道的聚乙烯用标准规范》.pdf
《ASTM F2623-2008 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing《升温的PE-RT材料标准尺寸比(SDR)为9管道的聚乙烯用标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2623-2008 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing《升温的PE-RT材料标准尺寸比(SDR)为9管道的聚乙烯用标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2623 08An American National StandardStandard Specification forPolyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1This standard is issued under the fixed designation F 2623; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification establishes requirements for polyeth-ylene of raised temperature (PE-RT) SDR
3、 9 tubing that isoutside diameter controlled, and pressure rated for water at73F (23C), 140F (60C) and 180F (82.2C). Included arerequirements for material, workmanship, dimensions and tol-erances, product tests, and markings for PE-RT tubing.1.2 The text of this specification references notes, footn
4、otes,and appendixes which provide explanatory material. Thesenotes and footnotes (excluding those in tables and figures) shallnot be considered as requirements of the specification.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinf
5、ormation only.1.4 The tubing produced under this specification shall bepermitted for use in general fluid transport, including hydronicsand irrigations systems.1.5 The following safety hazards caveat pertains only to thetest methods portion, Section 7, of this specification. Thisstandard does not pu
6、rport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D 6
7、18 Practice for Conditioning Plastics for TestingD 1598 Test Method for Time-to-Failure of Plastic PipeUnder Constant Internal PressureD 1599 Test Method for Resistance to Short-Time Hydrau-lic Pressure of Plastic Pipe, Tubing, and FittingsD 1600 Terminology for Abbreviated Terms Relating toPlastics
8、D 2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD 2837 Test Method for Obtaining Hydrostatic DesignBasis for Thermoplastic Pipe Materials or Pressure DesignBasis for Thermoplastic Pipe ProductsD 3350 Specification for Polyethylene Plastics Pipe andFittings MaterialsD
9、 3895 Test Method for Oxidative-Induction Time of Poly-olefins by Differential Scanning CalorimetryF 412 Terminology Relating to Plastic Piping Systems2.2 ANSI Standard:B36.10 Standards Dimensions of Steel Pipe (NTS)32.3 Federal Standard:FED-STD-123 Marking for Shipment (Civil Agencies)42.4 Military
10、 Standard:MIL-STD-129 Marking for Shipment and Storage42.5 PPI Standard:PPI TR-4 PPI Listing of Hydrostatic Design Basis (HDB),Strength Design Basis (SDB), Pressure Design Basis(PDB) and Minimum Required Strength (MRS) Ratingsfor Thermoplastic Piping Materials or Pipe53. Terminology3.1 DefinitionsDe
11、finitions are in accordance with Termi-nology F 412, and abbreviations are in accordance with Ter-minology D 1600, unless otherwise specified. The abbreviationfor polyethylene of raised temperature is PE-RT. Plastic tubingdenotes a particular diameter schedule of plastic pipe in whichoutside diamete
12、r of the tubing is equal to the nominal size plus18 in. Plastic pipe outside diameter schedule conforms toANSIB36.10.3.2 Definitions of Terms Specific to This Standard:3.2.1 hydrostatic design stress (HDS)the estimated maxi-mum tensile stress the material is capable of withstandingcontinuously with
13、a high degree of certainty that failure of thetube will not occur. This stress is circumferential when internalhydrostatic water pressure is applied.1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.26 on
14、 OlefinBased Pipe.Current edition approved March 1, 2008. Published March 2008. Originallyapproved in 2007. Last previous edition approved in 2007 as F 262307.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
15、ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from Standardization Documents Order Desk, Bldg. 4 Section D, 70
16、0Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.5Available from Plastics Pipe Institute (PPI), 105 Decker Court, Suite 825,Irving, TX 75062, http:/www.plasticpipe.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.2 pres
17、sure rating (PR)the estimated maximum waterpressure the tube is capable of withstanding continuously witha high degree of certainty that failure of the tube will not occur.3.2.3 relation between dimensions, hydrostatic designstress, and pressure ratingthe following expression, com-monly known as the
18、 ISO equation,6is used in this specificationto relate dimensions, hydrostatic design stress, and pressurerating:2S/P 5 DO/t! 1 (1)or2S/P 5 R 1where:S = hydrostatic design stress, psi (or MPa),P = pressure rating, psi (or MPa),DO= average outside diameter, in. (or mm),T = minimum wall thickness, in.
19、(or mm), andR = standard dimension ratio, SDR.3.2.4 standard dimension ratio (SDR)the ratio of outsidediameter to wall thickness. For PE-RT-tubing, it is calculatedby dividing the average outside diameter of the tubing in inchesor in millimeters by the minimum wall thickness in inches ormillimeters.
20、 If the wall thickness calculated by this formula isless than 0.070 in. (1.78 mm) it shall be arbitrarily increased to0.070 in. except for sizes18 in. and smaller. The SDR valuesshall be rounded to the nearest 0.5.3.2.5 standard thermoplastic material designated codethepipe material designation code
21、 shall consist of the abbreviationfor the type of plastic (PE) followed by Arabic numerals whichdescribe the short term properties in accordance with Specifi-cation D 3350, the hydrostatic design stress for water at 73.4F(23C) in units of 100 psi with any decimal figures dropped.Where the hydrostati
22、c design stress code contains less than twofigures, a zero is used before the number.4. Tubing Classification4.1 GeneralThis specification covers one PE-RT tubingmaterial in one standard dimension ratio, 9.0, and havingpressure ratings for water at 73F and 180F and optionally at140F. The pressure ra
23、tings decrease as the temperature isincreased.4.2 Standard Thermoplastic Pipe Dimension Ratio (SDR)This specification covers PE-RT tubing in one standard dimen-sion ratio (SDR 9) and nominal tubing sizes (NTS) from18 in.through 6 in. with a maximum continuous use temperature thatshall be 180F (82.2C
24、). The pressure ratings are uniform forall nominal tubing sizes.5. Materials5.1 GeneralThe plastic used to make tubing shall bevirgin plastic or reworked plastic, as specified in 5.3, and shallhave Plastics Pipe Institute (PPI) long-term hydrostatic designstress and pressure ratings at 73F and 180F.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26232008STANDARDSPECIFICATIONFORPOLYETHYLENEOFRAISEDTEMPERATUREPERTSDR9TUBING 升温 PERT 材料 标准 尺寸 SDR

链接地址:http://www.mydoc123.com/p-539124.html