1、Designation: F2181 14Standard Specification forWrought Seamless Stainless Steel Tubing for SurgicalImplants1This standard is issued under the fixed designation F2181; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the requirements for fivecompositions of wrought seamless stainless steel tubing for themanufac
3、ture of surgical implants. Material shall conform to theapplicable requirements of Specifications F138, F1314, F1586,F2229,orF2581. This specification addresses those productvariables that differentiate wrought seamless tubing from thebar and wire product forms covered in these specifications.1.2 Th
4、is specification applies to cold finished, straightlength tubing from 3 to 34 mm 0.125 to 1.315 in. nominaloutside diameter (OD) and 0.5 mm 0.020 in. and greaternominal wall thickness.1.3 The specifications in 2.1 are referred to as the ASTMmaterial standard(s) in this specification.1.4 The values s
5、tated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in nonconformancewith the standard.2. R
6、eferenced Documents2.1 ASTM Material Standards:2F138 Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for SurgicalImplants (UNS S31673)F1314 Specification for Wrought Nitrogen Strengthened 22Chromium13 Nickel5 Manganese2.5 MolybdenumStainless Steel Alloy Bar a
7、nd Wire for Surgical Implants(UNS S20910)F1586 Specification for Wrought Nitrogen Strengthened21Chromium10Nickel3Manganese2.5Molybdenum Stainless Steel Alloy Bar for SurgicalImplants (UNS S31675)F2229 Specification for Wrought, Nitrogen Strengthened23Manganese-21Chromium-1Molybdenum Low-NickelStainl
8、ess Steel Alloy Bar and Wire for Surgical Implants(UNS S29108)F2581 Specification for Wrought Nitrogen Strengthened11Manganese-17Chromium-3Molybdenum Low-NickelStainless Steel Alloy Bar and Wire for Surgical Implants(UNS S29225)2.2 ASTM Standards:A262 Practices for Detecting Susceptibility to Interg
9、ranularAttack in Austenitic Stainless SteelsA269 Specification for Seamless and Welded AusteniticStainless Steel Tubing for General ServiceA632 Specification for Seamless and Welded AusteniticStainless Steel Tubing (Small-Diameter) for General Ser-viceE29 Practice for Using Significant Digits in Tes
10、t Data toDetermine Conformance with SpecificationsF2257 Specification for Wrought Seamless or Welded andDrawn 18 Chromium-14Nickel-2.5Molybdenum StainlessSteel Small Diameter Tubing for Surgical Implants (UNSS31673)IEEE/ASTM SI 10 American National Standard for Use ofthe International System of Unit
11、s (SI): The Modern MetricSystem2.3 ISO Standards:3ISO 5832-1 Implants for SurgeryMetallic MaterialsPart1: Wrought Stainless SteelISO 5832-9 Implants for SurgeryMetallic MaterialsPart9: Wrought High Nitrogen Stainless Steel1This specification is under the jurisdiction of ASTM Committee F04 onMedical
12、and Surgical Materials and Devices and is the direct responsibility ofSubcommittee F04.12 on Metallurgical Materials.Current edition approved Oct. 1, 2014. Published January 2015. Originallyapproved in 2002. Last previous edition approved 2009 as F2181 09. DOI:10.1520/F2181-14.2For referenced ASTM s
13、tandards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Fl
14、oor, New York, NY 10036, http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1ISO 9001 Quality Management SystemRequirementsISO 13485 Medical devices - Qua
15、lity management systems -Requirements for regulatory purposes2.4 ASME Standard:4ASME Y14.5.1M Mathematical Definition of Dimensioningand Tolerancing Principles3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 individual wall thickness measurementany one ofthe wall thickness meas
16、urements taken around the circumfer-ence on any one transverse cross section of a single sample ofthe tube.3.1.2 lotthe total number of product produced from thesame melt heat under the same conditions at essentially thesame time.3.1.3 lot average concentricitythe arithmetic average ofthe sample con
17、centricities measured on a statistically represen-tative number of samples from the lot.3.1.4 lot average wall thicknessthe arithmetic average ofthe sample average wall thicknesses measured on a statisticallyrepresentative number of samples from the lot.3.1.5 nominal outside diameter (OD)the outside
18、 diameterspecified on the purchasers order or engineering drawingwithout regard to tolerance.3.1.6 nominal wall thicknessthe wall thickness specifiedon the purchasers order or engineering drawing without regardto tolerance.3.1.7 sample average wall thicknessthe arithmetic aver-age of all individual
19、wall thickness measurements measuredaround the circumference on any one transverse cross sectionof a single sample of tube.3.1.8 sample concentricitytwo times the offset betweenthe centers of the two circles representing the outside diameter(OD) and the inside diameter (ID) of the tube.3.1.8.1 Discu
20、ssionFor the purposes of this specification,the sample minimum wall and the sample maximum wallmeasured on any one transverse cross section of a singlesample shall be used to calculate sample concentricity. Thesample maximum, and sample minimum wall thickness shallbe the largest and smallest respect
21、ively of no less than fourindividual wall thickness measurements taken at uniformlyspaced locations around the circumference of a single sampleof the tube. Sample concentricity shall be expressed as apercent of the wall thickness and shall be calculated using thefollowing equation:sample concentrici
22、ty percent 5 2 3SA 2 BA1BD3100where:A = sample maximum wall, andB = sample minimum wall.3.1.9 sample maximum wall thicknessthe largest indi-vidual wall thickness measurement taken around the circum-ference on any one transverse cross section of a single sampleof tube.3.1.10 sample minimum wall thick
23、nessthe smallest indi-vidual wall thickness measurement taken around the circum-ference on any one transverse cross section of a single sampleof tube.4. General Requirements for Delivery4.1 In addition to the requirements of this specification, allapplicable requirements of the appropriate ASTM mate
24、rialstandard shall apply.4.2 In addition to the requirements of this specification, allapplicable seamless tubing requirements of Specification A269or Specification A632 shall apply. Flare testing is not appli-cable.4.3 If a conflict exists between this specification and thoselisted in Section 2, or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF21812014STANDARDSPECIFICATIONFORWROUGHTSEAMLESSSTAINLESSSTEELTUBINGFORSURGICALIMPLANTS 外科 植入 锻造

链接地址:http://www.mydoc123.com/p-537981.html