ASTM E3026-2015 Standard Guide for Readily Observable Moisture Affected Materials and Conditions Conducive to Elevated Moisture in Commercial Buildings Visual Moisture Assessment P.pdf
《ASTM E3026-2015 Standard Guide for Readily Observable Moisture Affected Materials and Conditions Conducive to Elevated Moisture in Commercial Buildings Visual Moisture Assessment P.pdf》由会员分享,可在线阅读,更多相关《ASTM E3026-2015 Standard Guide for Readily Observable Moisture Affected Materials and Conditions Conducive to Elevated Moisture in Commercial Buildings Visual Moisture Assessment P.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3026 15Standard Guide forReadily Observable Moisture Affected Materials andConditions Conducive to Elevated Moisture in CommercialBuildings: Visual Moisture Assessment Process1This standard is issued under the fixed designation E3026; the number immediately following the designation in
2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 PurposeThe purpose of this guide2is to d
3、efine goodcommercial practice for conducting a baseline survey forreadily observable moisture affected materials and conditionsconducive to elevated moisture in a commercial buildingrelated to a commercial real estate transaction or commercialreal estate asset management by conducting: a walk-throug
4、hsurvey, document reviews, and interviews as outlined withinthis guide. This guide is intended to provide a practical meansfor the visual identification of moisture affected materials andphysical deficiencies conducive to elevated moisture as a resultof water infiltration through the building envelo
5、pe orsubstructure, or generated within the subject building as aresult of processes or mechanical systems, excluding deminimis conditions. This guide is to allow a user to assessgeneral moisture concerns, as well as the potential need forfurther assessment or other actions that may be appropriate th
6、atare beyond the scope of this guide. For purposes of this guide,the initialism “VMA”or“Visual Moisture Assessment” is usedinterchangeably with this guides full title.1.2 Purpose LimitationsWhile a VMA may be used tosurvey for readily identifiable moisture affected materials andphysical deficiencies
7、 conducive to elevated moisture, the VMAis not designed to serve as comprehensivesurvey for thepresence of moisture affected materials and physical deficien-cies conducive to elevated moisture in all or most areas in acommercial building. It is not intended to reduce or eliminatethe risks that eleva
8、ted moisture may pose to the subjectbuilding or its occupants.1.3 Considerations Beyond This ScopeThe use of thisguide is strictly limited to the scope set forth in this section.Section 12 of this guide identifies, for informational purposes,certain physical conditions (not an all-inclusive list) th
9、at mayexist at a property and certain activities or procedures (not anall-inclusive list) that are beyond the scope of this guide butmay warrant consideration by users. The need to investigateany such conditions in the providers scope of services shouldbe evaluated based upon, among other factors, t
10、he nature of theproperty and the reason for conducting the VMA. The scope ofsuch further investigation or testing services should be agreedupon between the user and the provider as additional services,which are beyond the scope of this guide, prior to initiation ofthe VMA process. The responsibility
11、 to initiate work beyondthe scope of this guide lies with the user.1.3.1 Sampling for suspect fungi and other forms of biologi-cal growth is a non-scope consideration under this guide.1.3.2 Sampling or otherwise measuring for moisture is anon-scope consideration under this guide.1.4 Organization of
12、the GuideThis guide has 13 sectionsand three appendices. Section 1 defines the Scope. Section 2 isReferenced Documents. Section 3 is Terminology. Section 4defines the Significance and Use of this guide. Section 5describes User Responsibilities. Sections 6 through 11 provideguidelines for the main bo
13、dy of the report, including the scopeof the walk-through survey and preparation of the report.Section 12 and Appendix X1 identify Out of Scope Consider-ations. Section 13 lists keywords for Internet reference. Ap-pendix X1 provides the user with additional VMA scopeconsiderations, whereby a user may
14、 increase this guidesbaseline scope of due diligence to be exercised by the provider,Appendix X2 provides the user with a suggested InterviewChecklist, and Appendix X3 provides the user with a suggestedField Checklist.1.5 This standard does not purport to address all of thesafety concerns, if any, a
15、ssociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1This guide is under the jurisdiction ofASTM Committee E50 on EnvironmentalAssessment, Risk Manag
16、ement and Corrective Action and is the direct responsibil-ity of Subcommittee E50.02 on Real Estate Assessment and Management.Current edition approved Aug. 1, 2015. Published September 2015. DOI:10.1520/E3026152Whenever terms defined in Section 3 are used in this guide, they are in italics.Copyright
17、 ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12. Referenced Documents2.1 ASTM Standards:3D7338 Guide for Assessment Of Fungal Growth in Build-ingsE631 Terminology of Building ConstructionsE1527 Practice for Environmental Site Assessments: Ph
18、ase IEnvironmental Site Assessment ProcessE1528 Practice for Limited Environmental Due Diligence:Transaction Screen ProcessE2018 Guide for Property Condition Assessments: BaselineProperty Condition Assessment Process3. Terminology3.1 ScopeThis section provides definitions, descriptionsof terms, and
19、a list of acronyms for many of the words used inthis guide. The terms are an integral part of the guide and arecritical to an understanding of the guide and its use.3.2 Definitions:3.2.1 actual knowledgethe knowledge actually possessedby an individual who is a real person, rather than an entity.Actu
20、al knowledge is to be distinguished from constructiveknowledge, which is knowledge imputed to an individual orentity.3.2.2 architectdesignation reserved by law for a personprofessionally qualified, examined, and registered by the ap-propriate governmental board having jurisdiction, to providearchite
21、ctural services including, but not limited to, analysis ofproject requirements and conditions, development of projectdesign, production of construction drawings and specifications,and administration of construction contracts.3.2.3 baselinethe minimum level of observations, inquiry,research, document
22、 review, and preparation of opinions forconducting a VMA as described in this guide.3.2.4 biological growthvisible moisture-related growthssuch as algae, fungi, lichens, mosses, bacteria, and higherplants. The term may also be considered to include referencesto mold, mildew, mushrooms, or any plant
23、matter.3.2.5 building department recordsthose records of thelocal government agency in which the property is locatedindicating permission of the local government to construct,alter, or demolish improvements on the property. Often build-ing department records are located in the building departmentof
24、a municipality or county.3.2.6 building envelopethe outer elements of a building,both above and below ground, which divide the external fromthe internal environments. Commonly included are exteriorwalls, windows, doors, roofs and subfloors. E6313.2.7 building systeminteracting or independent compo-n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME30262015STANDARDGUIDEFORREADILYOBSERVABLEMOISTUREAFFECTEDMATERIALSANDCONDITIONSCONDUCIVETOELEVATEDMOISTUREINCOMMERCIALBUILDINGSVISUALMOISTUREASSESSMENTPPDF

链接地址:http://www.mydoc123.com/p-532256.html