ASTM E2427-2018 Standard Test Method for Acceptance by Performance Testing for Sieves.pdf
《ASTM E2427-2018 Standard Test Method for Acceptance by Performance Testing for Sieves.pdf》由会员分享,可在线阅读,更多相关《ASTM E2427-2018 Standard Test Method for Acceptance by Performance Testing for Sieves.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2427 13E2427 18Standard Test Method forAcceptance by Performance Testing for Sieves1This standard is issued under the fixed designation E2427; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is a performance test for acceptance of sieves.1.2 This test method compares the performance of a sieve against an
3、inspection or calibration sieve using a known quantity ofreference material such that the long-term stability of sieves can be measured.1.3 This is a test method for checking the accuracy and long-term reliability of test sieves. Since it is not possible to adjust themeasuring capability of a test s
4、ieve, the test method is designed to offer a verification procedure based on sieving performance bycomparison to a standard reference. This test method is not proposed as an alternative to the inspection methods in accordance withSpecification E11 or the procedures in MNL 32.1.4 UnitsThe values stat
5、ed in SI units are to be regarded as standard. All otherThe additional values given are included forinformation only.only and are not considered standard.1.5 This test method standard does not purport to address all of the safety concerns, if any, associated with its use. It is theresponsibility of
6、the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices anddetermine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardizatione
7、stablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.1 This test method is under the jurisdiction of ASTM Committee E29 on Particle and Spray Characterizat
8、ion and is the direct responsibility of Subcommittee E29.01 onSieves, Sieving Methods, and Screening Media.Current edition approved Nov. 1, 2013Oct. 1, 2018. Published November 2013October 2018. Originally approved in 2005. Last previous edition approved in 20112013as E2427 11.E2427 13. DOI: 10.1520
9、/E2427-13.10.1520/E2427-18.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends t
10、hat users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12. Referenced Documen
11、ts2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth and Test SievesE177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodE1638 Terminology Relating to Sieves, Siev
12、ing Methods, and Screening MediaMNL 32 Manual on Test Sieving Methods Guidelines for Establishing Sieve Analysis Procedures3. Terminology3.1 Definitions of terms relating to sieve analysis can be found in Terminology E1638.3.1 DefinitionsFor terms relating to sieve analysis, refer to Terminology E16
13、38.3.1.1 calibration test sieve, na test sieve manufactured using sieve cloth which has been inspected after being mounted in thesieve frame, and that meets the requirements of Table 1 of Specification E11 in part based on the standard deviation of the requirednumber of sample openings in the test s
14、ieve (Column 11) not exceeding the maximum allowable for a confidence level of 99.73 %(Column 12). E113.1.2 endpoint, npoint at which no material falls through the sieve concluding the sieving, taking into account sampledegradation.3.1.3 inspection test sieve, natest sieve manufactured using sieve c
15、loth which has been inspected after being mounted in thesieve frame, and that meets the requirements of Table 1 of Specification E11 in part based on the standard deviation of the requirednumber of sample openings in the test sieve (Column 9) not exceeding the maximum allowable for a confidence leve
16、l of 99 %(Column 10). E113.1.4 percent retained, nmass fraction percentage of material that is left upon or retained by the sieve after the test has beenperformed.3.1.5 sieve, nan apparatus consisting of a medium with regularly spaced apertures of uniform size, mounted in a suitableframe or holder,
17、for use in separating material according to size.3.1.6 sieve shaker, nthe device used to agitate the sieves, excluding hand sieving.3.2 calibration test sieve, na test sieve manufactured using sieve cloth which has been inspected after being mounted in thesieve frame, and that meets the requirements
18、 of Table 1 of Specification E11 in part based on the standard deviation of the requirednumber of sample openings in the test sieve (Column 11) not exceeding the maximum allowable for a confidence level of 99.73 %(Column 12). E113.3 endpoint, npoint at which no material falls through the sieve concl
19、uding the sieving, taking into account sampledegradation.3.4 inspection test sieve, natest sieve manufactured using sieve cloth which has been inspected after being mounted in thesieve frame, and that meets the requirements of Table 1 of Specification E11 in part based on the standard deviation of t
20、he requirednumber of sample openings in the test sieve (Column 9) not exceeding the maximum allowable for a confidence level of 99 %(Column 10). E113.5 percent retained, nmass fraction percentage of material that is left upon or retained by the sieve after the test has beenperformed.3.6 sieve, nan a
21、pparatus consisting of a medium with regularly spaced apertures of uniform size, mounted in a suitable frameor holder, for use in separating material according to size.3.7 sieve shaker, nthe mechanical device or method used to shake the sieves, excluding hand sieving.4. Significance and Use4.1 This
22、test method may be used by producers, users, and general interest parties for research and development or productionquality control work, and is useful for the comparison of sieves.4.2 Because the reference materials particle size distribution will affect the acceptance tolerance, the user should de
23、termine anacceptance tolerance based on their specific reference material.5. Interferences5.1 The long-term use of sieves can compromise the reliability of test results. Depending on the type of materials beingmeasured, wear can occur on the diameter of the wires causing opening sizes to change and
24、measuring capability to drift.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standardsstandards Document Summary page on the ASTM website.E2427 1825.2 The speci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24272018STANDARDTESTMETHODFORACCEPTANCEBYPERFORMANCETESTINGFORSIEVESPDF

链接地址:http://www.mydoc123.com/p-531108.html