ASTM E1863-2018 Standard Test Method for Analysis of Acrylonitrile by Gas Chromatography.pdf
《ASTM E1863-2018 Standard Test Method for Analysis of Acrylonitrile by Gas Chromatography.pdf》由会员分享,可在线阅读,更多相关《ASTM E1863-2018 Standard Test Method for Analysis of Acrylonitrile by Gas Chromatography.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1863 18Standard Test Method forAnalysis of Acrylonitrile by Gas Chromatography1This standard is issued under the fixed designation E1863; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the impu-rities in, and the purity of, acrylonitrile by flame ionizationdetector gas chromat
3、ography. It is applicable to acrylonitrile inthe range of 99 to 100 % purity.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its u
4、se. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Specific hazard statements are given in Sections 6 and 7.1.4 Review the current MSDS for detailed inf
5、ormationconcerning toxicity, first aid procedures, and safety precau-tions.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and R
6、ecom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals (Withdrawn 2009)3E1178 Test Methods
7、for Analysis of Acrylonitrile (With-drawn 2016)33. Summary of Test Method3.1 In this test method, a representative sample of acrylo-nitrile is introduced in a gas chromatograph equipped with aflame ionization detector and a capillary column where specificimpurities are separated from the acrylonitri
8、le. The chromato-graphic area for each impurity is compared to the area of theinternal standard, toluene or other suitable known, added to thesample. From response factors of these impurities relative tothat of the internal standard and the amount of the standardadded, the concentration of the impur
9、ities are calculated. Otherimpurities, such as water, are obtained by use of Test MethodsE1178. The acrylonitrile content is obtained by subtracting thetotal amount of all impurities from 100.0.4. Significance and Use4.1 This test method is designed to obtain acrylonitrilepurity on the basis of impu
10、rities normally present in acryloni-trile and may be useful for final product inspection and processcontrol.4.2 This test method will measure the following impurities:acetone, acrolein, acetonitrile, and acetaldehyde. It also willallow calibration of other impurities including benzene,methacrylonitr
11、ile, oxazole, propionitrile, cis-crotononitrile,trans-crotononitrile, and others where specific impurity stan-dards are available.5. Apparatus5.1 Capillary Gas ChromatographAny gas chromato-graph equipped with a flame ionization detector and a splitinjection system for use with capillary columns tha
12、t can beoperated at the conditions given in Table 1.5.2 ColumnThe column, such as Supelcowax 10,4mustgive satisfactory resolution and proper peak shapes for thecomponents listed in Fig. 1.5.3 Recorder/IntegratorElectronic integration is recom-mended for this analysis.5.4 Syringe, 10 L capacity.1This
13、 test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.15 on Thermoplastic Materi-als.Current edition approved Oct. 1, 2018. Published October 2018. Originallyapproved in 1997. Last previous edition approved in 2007 as E1863 07, wh
14、ich waswithdrawn January 2016 and reinstated in October 2018. DOI: 10.1520/E1863-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary p
15、age onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4A Supelcowax 10 fused silica capillary column (60 m by 0.32 mm ID by 1 mfilm thickness), has been found to be suitable, but similar polar wax columns fromother vendors may be used after shown
16、to be suitable.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevel
17、opment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.16. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reage
18、nts conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society whereTABLE 1 Typical Instrument ParametersDetector: Flame ionizationColumn:length: 60 minside diameter: 0.32 mmstationary phase: Supelcowax 10support: Fused silicafilm thickness, m: 1.0Temperatu
19、re, Cinjector: 225detector: 350oven: 50 initial, hold 25 min, rate 10/min, 90 final, hold 20 minCarrier Gas: HeliumFlow: 20 cm/sTotal chromatograph run time: 54 minInternal standard: TolueneSample size, L 2.0Split ratio 1:100Retention times, min (refer to Fig. 1 for typical chromatogram)Acetaldehyde
20、 6Acetone 9Acrolein 10Benzene 18Methacrylonitrile 23Oxazole 29Propionitrile 29.5Toluene 30cis-Crotononitrile 38trans-Crotononitrile 49FIG. 1 Typical Chromatogram of Acrylonitrile Calibration MixtureE1863 182such specifications are available.5Other grades may be used,provided it is first ascertained
21、that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Carrier Gas, helium minimum purity 99.995 mol %.6.3 Hydrogen, high purity.6.4 Air, hydrogen free, high purity.6.5 Toluene, 99.0 % min purity or other internal standard,previously a
22、nalyzed free of compounds coeluting with impu-rities in the sample.6.6 Acrylonitrile, highest purity available.NOTE 1High purity acrylonitrile can be obtained by fractionaldistillation.6.7 Acetone, at least 96 % pure.6.8 Acrolein, at least 96 % pure.6.9 Acetonitrile, at least 96 % pure.6.10 Acetalde
23、hyde, at least 96 % pure.6.11 Benzene, at least 96 % pure.6.12 Methacrylonitrile, at least 96 % pure.6.13 Propionitrile, at least 96 % pure.6.14 Crotononitrile, cis and trans, at least 96 % pure,available only as a mixture.7. Hazards7.1 Acrylonitrile potentially is hazardous to human health ifnot pr
24、operly handled. Acrylonitrile is a suspected humancarcinogen. Use acrylonitrile in a well-ventilated hood.7.2 Acrylonitrile can contribute to a toxic condition insystems of the human body, from inhalation, swallowing orcontact with the eyes or skin. Direct contact with acrylonitrilealso can cause sk
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18632018STANDARDTESTMETHODFORANALYSISOFACRYLONITRILEBYGASCHROMATOGRAPHYPDF

链接地址:http://www.mydoc123.com/p-529669.html