ASTM E1346-1990(2010) Standard Practice for Bulk Sampling Handling and Preparing Edible Vegetable Oils for Sensory Evaluation《感官评估用大量取样 搬运 和制备食用植物油的标准操作规程》.pdf
《ASTM E1346-1990(2010) Standard Practice for Bulk Sampling Handling and Preparing Edible Vegetable Oils for Sensory Evaluation《感官评估用大量取样 搬运 和制备食用植物油的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1346-1990(2010) Standard Practice for Bulk Sampling Handling and Preparing Edible Vegetable Oils for Sensory Evaluation《感官评估用大量取样 搬运 和制备食用植物油的标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1346 90 (Reapproved 2010)Standard Practice forBulk Sampling, Handling, and Preparing Edible VegetableOils for Sensory Evaluation1This standard is issued under the fixed designation E1346; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the recommended procedures forbulk sampling, handling, and prepari
3、ng edible vegetable oil(liquid at room temperature) prior to sensory evaluation.1.2 This practice is consistent with the background infor-mation presented in ASTM STP 433, ASTM STP 434, andASTM STP 758. These should be consulted for supplementalguidance.1.3 The values stated in SI units are to be re
4、garded asstandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determin
5、e the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Publications:2ASTM STP 433 Basic Principles of Sensory EvaluationASTM STP 434 Manual on Sensory Testing MethodsASTM STP 758 Guidelines for the Selection and Trainingof Sensory Panel Members2.2 AOCS Standard:3
6、Method C1-47 Sampling3. Summary of Practice3.1 This practice consists of the following basic steps:removing oil from bulk source, transporting and starting oilprior to evaluation, preparing oils for evaluation, presentingsamples to panel, and cleaning glassware.4. Significance and Use4.1 This practi
7、ce is designed for use by the oil processor orresearch laboratory for evaluation by a trained sensory panel,or for use by quality control (QC) and quality assurance (QA)personnel for sampling from a tank truck, car, or any other bulktransportation container, or by both.4.2 The consistent use of this
8、 practice will provide repre-sentative samples for all sensory, chemical and physicalanalyses and will protect the oil from oxidation.4.3 The objective of this practice is to ensure that the sampleis representative of the sample source from the time ofsampling until the time of evaluation and to pro
9、tect oil qualityduring that time.4.4 This practice addresses neither evaluation and scalingtechniques, nor the sampling, handling, and preparing of solidfats.5. Apparatus5.1 Liquid Zone Sampler,3or core sampler, or trier.4,55.2 Wide-Mouth Jars, made of polyethylene terephthalate,0.5 to 1.0 L.5.3 Amb
10、er Glass Bottles, 250 mLto 1 L, with narrow-mouthtops that will withstand freezer temperatures.5.4 Plastic Caps with Liners, or tape (PTFE pipe threadtape), to cover top of bottle opening before capping with newnon-metallic screw type caps. Tape should be 2.5 cm in widthor wider to completely cover
11、bottle openings.5.5 Glass Funnels.5.6 Glove Box with inert gas nitrogen atmosphere, includ-ing an oxygen scavenging device.5.7 Glass Vial, 50 mL. Use amber glass for flavor evaluationand clear glass for visual examination of oil.1This practice is under the jurisdiction of ASTM Committee E18 on Senso
12、ryEvaluation and is the direct responsibility of Subcommittee E18.06 on Food andBeverage Evaluation.Current edition approved Aug. 15, 2010. Published December 2010. Originallyapproved in 1990. Last previous edition approved in 2006 as E1346 90 (2006).DOI: 10.1520/E1346-90R10.2Available from ASTM Int
13、ernational Headquarters, 100 Barr Harbor Drive, POBox C700, West Conshohocken, PA 19428-2959.3Available from American Oil Chemists Society, P.O. Box 3989, Champaign,IL 61826.4Available from Zone Devices, Inc., San Rafael, CA.5Available from Refinery Supply Co., Tulsa, OK.1Copyright ASTM Internationa
14、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.8 Standard Disposable Glass Pipets, 10 mL, one per eachsample.5.9 Circulating Waterbath, with automatic timer, thermostatand rack.5.10 Waterbath Thermometer, with range from 20 to 100Cin 1C divisions, calibrated
15、 for 76 mm immersion, 305 mmlong.6. Precautions6.1 Oil submitted for chemical and physical testing and forsensory evaluation should be from the same bulk sampling.Tank trucks, cars, or any other bulk transportation containersmay be filled with as many as seven layers and each level of oilmay be slig
16、htly different in quality. Oil samples should behandled in the same manner and time frame to ensure high datacorrelation.6.2 Do not expose oil to any environmental condition (forexample, light, heat, oxygen, moisture) or any equipment(metals) that will cause oxidation of the oil and alter sensorycha
17、racteristics of the oil.6.3 Use only new, clean, dry, and odor-free polyethyleneterephthalate wide-mouth jars to collect oil samples; dispose ofjars rather than cleaning them.6.4 Flush bottles with nitrogen in a glove box prior to fillingthe bottle.6.5 Obtain a representative oil sample for all eval
18、uations(sensory, chemical, instrumental); unblended multiple samplesmay produce different results.6.6 Do not allow glass containers in processing or produc-tion areas where oil sampling is done. Use new plasticcontainers such as polyethylene terephthalate bottles for initialsampling. Flush empty bot
19、tle with nitrogen as described in 6.4.6.7 Transfer oil from plastic bottle to recommended glassbottles within one hour of collection and flush headspace withnitrogen to minimize potential transfer of odors or flavors fromthe plastic container to the oil (conduct procedure in glove boxunder nitrogen
20、atmosphere).6.8 Use PFTE-lined caps or PFTE tape under caps to protectoil from off-odors or flavors imparted from metallic or unlinedplastic caps.6.9 Store oil in amber glass bottles to protect the oil fromlight oxidation.6.10 Choose size of storage bottle based on purpose ofevaluation, amount of oi
21、l required for each testing session orfor number of panelists, and amount of oil needed for instru-mental or chemical tests. For example, a 1 L sample of oil thatrequires evaluation quarterly should be stored in four 250-mLbottles.6.11 Discard any unused oil.7. Procedures for Handling Samples Obtain
22、ed from BulkStorage7.1 Refer to the AOCS Official Method C1-47 on oilsampling for specifications for detailed information on equip-ment and procedures.7.2 Flush bottle with nitrogen and fill bottle with oil,allowing a small amount of headspace. Flush headspace withnitrogen to remove oxygen, and cap
23、bottle (conduct procedurein glove box under nitrogen atmosphere).7.3 Headspace Considerations:7.3.1 Keep an inert gas such as nitrogen in contact with theoil at all times to avoid exposure of the oil to oxygen.7.3.2 Leave 0.5 to 1 cm of headspace between the oil andthe cap liner.7.3.3 Fill headspace
24、 with inert gas (nitrogen) to remove alloxygen which deteriorates the oil. Flush only the headspacewith nitrogen since bubbling nitrogen through oil for shortperiods of time has little benefit.7.3.4 Analyze headspace for oxygen to ensure that bottlesare being flushed correctly as follows: (1) Flush
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME134619902010STANDARDPRACTICEFORBULKSAMPLINGHANDLINGANDPREPARINGEDIBLEVEGETABLEOILSFORSENSORYEVALUATION

链接地址:http://www.mydoc123.com/p-528484.html