《ASTM D7353-2007(2013) 7500 Standard Practice for Sampling of Liquids in Waste Management Activities Using a Peristaltic Pump《废物管理活动中用蠕动泵进行液体取样的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7353-2007(2013) 7500 Standard Practice for Sampling of Liquids in Waste Management Activities Using a Peristaltic Pump《废物管理活动中用蠕动泵进行液体取样的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7353 07 (Reapproved 2013)Standard Practice forSampling of Liquids in Waste Management Activities Usinga Peristaltic Pump1This standard is issued under the fixed designation D7353; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the use of a peristaltic pump forsampling liquids from multiple depths. It
3、 is applicable for awide range of fluids including: high-viscosity fluids, aggressiveand corrosive fluids, high-purity solutions and abrasive fluids.It is especially useful for sampling liquids that require com-plete isolation from the pump.1.2 This practice includes the determination of sampledepth
4、, pump set up and collecting a sample to be analyzed.1.3 This practice is not intended to give detailed instructionsfor running a peristaltic pump or recommend which peristalticpump to purchase. It instructs the field personnel how toconnect the pump and collect a sample.1.4 This standard does not p
5、urport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2
6、D4448 Guide for Sampling Ground-Water Monitoring WellsD4687 Guide for General Planning of Waste SamplingD4840 Guide for Sample Chain-of-Custody ProceduresD5681 Terminology for Waste and Waste ManagementD5792 Practice for Generation of Environmental Data Re-lated to Waste Management Activities: Devel
7、opment ofData Quality ObjectivesD5956 Guide for Sampling Strategies for HeterogeneousWastesD6044 Guide for Representative Sampling for Managementof Waste and Contaminated MediaD6063 Guide for Sampling of Drums and Similar Containersby Field PersonnelD6232 Guide for Selection of Sampling Equipment fo
8、rWaste and Contaminated Media Data CollectionActivitiesD6250 Practice for Derivation of Decision Point and Confi-dence Limit for Statistical Testing of Mean Concentrationin Waste Management DecisionsD6311 Guide for Generation of Environmental Data Relatedto Waste Management Activities: Selection and
9、 Optimiza-tion of Sampling DesignD6634 Guide for the Selection of Purging and SamplingDevices for Ground-Water Monitoring Wells3. Terminology3.1 Definitions:3.2 See Terminology D5681.4. Summary of Practice4.1 A peristaltic pump is a suction lift pump (see Fig. 1b). Alength of polytetrafluoroethylene
10、 (PTFE) or other suitabletubing such as Silastic tubing is placed in the liquid at anydepth up to 7.6 m (25 ft.) for water or less depending upon thedensity of the sample being taken. The other end is connectedto the piece of flexible tubing which has been threaded aroundthe rotor of the peristaltic
11、 pump (see Fig. 1a). A second pieceof PTFE or other suitable tubing is connected to the dischargeend of the flexible tubing to allow the liquid to be containerizedor sampled. One can fill a vacuum-worthy sample containerafter attaching two tubes to it, one from the top of the pumpinlet, and the othe
12、r from a lower level to the source (see Fig.1c).5. Significance and Use5.1 This practice can be used in sampling drums, tanks, andsimilar containers and in sampling monitoring and waste wellsincluding small diameter (1 in.) wells. The pump can collectsamples from multiple depths. The samples can be
13、high-viscosity fluids, aggressive and corrosive fluids, high-puritysolutions and abrasive fluids. The pump can be used to mixsamples (see D6063).5.2 Peristaltic pumps use a vacuum to transport the samples.This vacuum may cause some degassing and loss of volatile1This practice is under the jurisdicti
14、on of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.01.03 onSampling Equipment.Current edition approved Feb. 1, 2013. Published February 2013. Originallyapproved in 2007. Last previous edition approved in 2007 as D7353 07. DOI:10.1520/D7353-07R13.2For ref
15、erenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, Wes
16、t Conshohocken, PA 19428-2959. United States1organic compounds (VOCs) from the sample. When precisequantitative data for VOCs and dissolved gases are notrequired, peristaltic pumps may be used.5.3 The pump is self-priming, runs dry without damage, andis completely isolated from the pumped fluid. A s
17、ample can betaken on the intake or discharge side of the pump.5.4 Some additional advantages of the peristaltic pump are:decontamination of the pump motor is not necessary and thetubing in the pump is disposable and easy to replace. Thepumps can be easily started and stopped and can pump fluidsat a
18、wide range of pressures and flow rates.5.5 The place, quality and quantity, frequency, and time ofsampling is dependent upon the decisions that are to be made(see D6250), sampling design (see D6311), the sample, theheterogeneity of the samples (see D5956), how representativethe sample is (see D6044)
19、, and the parameters to be tested asdetermined by the data quality objectives (DQOs) (see D5792).6. Sampling Equipment6.1 It is recommended that two peristaltic pumps be taken tothe site with two pump specific clamps per unit.NOTE 1There are many peristaltic pumps on the market from severalmanufactu
20、rers. Consult with the manufacturers to determine the capabili-ties of each pump for your application.6.2 Two fully charged batteries (or other applicable batteriesor AC/DC converter as required).6.3 New medical-grade rubber/silicone tubing (Dow-Corning Silastic or equivalent). In corrosive situatio
21、ns, a lengthof PTFE tubing is used.6.4 Applicable tubing couplers for discharge and intake asneeded.6.5 Tape measure or water level instrument.6.6 Waste container.6.7 Plastic, glass, or other non-reactive containers should beused as specified by the site sampling plan (see Guide D4687).7. General Sa
22、mple Collecltion7.1 Review the work or sampling plan.7.2 Check to make sure that the supply of samplecontainers, labels, ice chest, stop watch or timing device,composite collection container if required, and sampling equip-ment in place are adequate and correct. There should besampling forms, or log
23、 books, or equivalent for recording fieldinformation such as date, time the sample was taken, samplersname, physical description of the sampling location and anyother information which might impact the validity of thesample. The log books, sampling forms, and bottle labelsshould be signed or initial
24、ed.7.3 Provision should be made for split samples and fieldquality control samples, such as trip blanks, equipment blanks,and field spikes.8. Pre-sampling Testing8.1 Remove the pump cover plate. Slide the tubing throughthe clamps, position the clamps in their seats, and gently rotatethe pump mast to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7353200720137500STANDARDPRACTICEFORSAMPLINGOFLIQUIDSINWASTEMANAGEMENTACTIVITIESUSINGAPERISTALTICPUMP

链接地址:http://www.mydoc123.com/p-525256.html