《ASTM D6950-2004 Standard Practice for Application of Heat Weldable Atactic Polypropylene (APP) Modified Bituminous Waterproofing Membranes Systems for New Building Decks《新建筑物平台用热力可.pdf》由会员分享,可在线阅读,更多相关《ASTM D6950-2004 Standard Practice for Application of Heat Weldable Atactic Polypropylene (APP) Modified Bituminous Waterproofing Membranes Systems for New Building Decks《新建筑物平台用热力可.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6950 04Standard Practice forApplication of Heat Weldable Atactic Polypropylene (APP)Modified Bituminous Waterproofing Membranes Systems forNew Building Decks1This standard is issued under the fixed designation D 6950; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the minimum application recom-mend
3、ations for heat weldable atactic polypropylene (APP)modified bituminous systems used as part of a new horizontalwaterproofing system over occupied spaces of buildings wherecovered by a separate wearing course.1.2 For the purpose of this practice, the substrate shall bestructurally sound, sloped to d
4、rain, able to accept the weight ofthe membrane and other system materials, and meet the localbuilding code requirements. Similarly, all components of thewaterproofing system are assumed to comply with any federal,state, and local environmental regulations that may be in effectat the time of installa
5、tion. Expansion joints, insulation, drain-age layers, protection boards, filter sheets, and the wearingsurfaces are beyond the scope of this practice.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does no
6、t purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standard
7、s:2D 41 Specification for Asphalt Primer Used in Roofing,Dampproofing, and WaterproofingD 1079 Terminology Relating to Roofing, Waterproofingand Bituminous MaterialsD 4586 Specification for Asphalt Roof Cement, Asbestos-FreeD 5295 Guide for the Preparation of Concrete Surfaces forAdhered (Bonded) Me
8、mbrane Waterproofing SystemsD 5898 Guide for Standard Details for Adhered SheetWaterproofingD 5957 Guide for Food Testing Horizontal WaterproofingInstallationsD 6222 Specification for Atactic Polypropylene (APP)Modified Bituminous Sheet Materials Using PolyesterReinforcementsD 6223 Specification for
9、 Atactic Polypropylene (APP)Modified Bituminous Sheet Materials Using a Combina-tion of Polyester and Glass Fiber ReinforcementsD 6451 Specification for Application of Asphalt Based Pro-tection BoardD 6506 Specification for Asphalt Based Protection Boardfor Below-Grade Waterproofing2.2 American Conc
10、rete Institute Standard:ACI 301 Specifications for Structural Concrete for Build-ings32.3 FMRC Standard:FM 4470 Approval Standard, Class Roof Covers, latestedition; where applicable for corrosion resistant compo-nents43. Terminology3.1 For definition of terms, see Terminology D 1079.3.1.1 constructi
11、on jointa butt joint formed in a structuralslab in order to end one pour and start another pour later. Thejoint is usually a cold joint and maybe held together withreinforcing steel in the slab, or the steel may be discontinuousby design.3.1.2 heat weldingthe attachment and joining of themodified bi
12、tumen membrane sheet by heating its surface witha torch, hot air, or other means of direct thermal contact.4. Significance and Use4.1 This practice provides general procedures, information,guidelines, and precautions for the application of heat welded1This practice is under the jurisdiction of ASTM
13、Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.22 on Water-proofing and Damproofing Systems.Current edition approved July 1, 2004. Published July 2004.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service
14、 at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Concrete Institute, P.O. Box 9094, Farmington Hills,MI 48333.4Available from Factory Mutual Research, 11511 Boston-Providence Turnpike,P.
15、O. Box 9102, Norwood, MA 02062-9102.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.modified bituminous waterproofing systems used as part of anew horizontal waterproofing system.4.2 This practice is not all-inclusive and is intended
16、 only tosupplement detailed instructions from designers and systemmanufacturers.4.3 The horizontal (low sloped) deck or substrate referred toin this practice is reinforced cast-in-place structural concrete.5. Delivery of Materials5.1 Deliver materials in the manufacturers original un-opened packages
17、 and containers.5.2 All materials or material packaging must be clearlymarked in a weather-resistant manner with type, stock, or lotnumber, and other pertinent information (for example: thick-ness, size, weight, manufacturers name, ASTM specification)and other related information as required by the
18、purchaser.6. Storage and Handling of Materials6.1 Store materials on raised platforms or pallets. Store rollson end with selvage ends up. Materials shall be stored in a dry,ventilated, and weatherproof location. Avoid damage or em-bedment of foreign materials.6.2 Store membrane materials to prevent
19、system suppliersmarkings from being destroyed.6.3 Store primer in tightly closed original containers attemperatures recommended by the system supplier. Do nottransfer contents of one container to another container. Do notmix different materials. Do not thin primer, except as directedby the system ma
20、nufacturer.6.4 Modified bituminous rolls and other materials are to bebrought to the job site in good condition, handled so as not tobe damaged. Materials improperly stored or that become wet ordamaged shall be identified, marked, and removed from thesite.7. Environmental Conditions7.1 Do not instal
21、l sheet material during inclement weather,on wet or frost-covered surfaces, during rainfall, blowing dust,or high winds that will inhibit or interfere with sheet materialadhesion.7.2 Follow recommendations of system supplier for systemapplication procedures when ambient temperatures are below5C (40F
22、).7.3 Surfaces to receive the membrane shall be protectedfrom dirt and debris.8. Materials8.1 Modified Bituminous SheetPrefabricated modified bi-tuminous sheets reinforced with either polyester or glass fiberfabrics or a combination of the two which use atactic polypro-pylene (APP) as the primary mo
23、difier and meet the require-ments of Specification D 6222 or D 6223.8.2 Primer, asphalt primer. See Specification D 41.8.3 Roof Cement, asphalt roof cement, asbestos-free. SeeSpecification D 4586.8.4 Protection Board, asphalt based protection board. SeeSpecification D 6506.8.5 Mechanical AffxmentsTh
24、e mechanical fasteners andstress distribution bars or strips specified for use in the systemmust meet the corrosion guidelines outlined in FMRC Standard4470.9. Substrate Preparation9.1 The structural slab should have a finish of sufficientlyrough texture to provide a mechanical bond for the membrane
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD69502004STANDARDPRACTICEFORAPPLICATIONOFHEATWELDABLEATACTICPOLYPROPYLENEAPPMODIFIEDBITUMINOUSWATERPROOFINGMEMBRANESSYSTEMSFORNEWBUILDINGDECKS

链接地址:http://www.mydoc123.com/p-524072.html