ASTM D5293-2010e1 Standard Test Method for Apparent Viscosity of Engine Oils and Base Stocks Between &x2013 5 and &x2013 35&x00B0 C Using Cold-Cranking Simulator《使用冷启动模拟器测定机油表面粘度和x.pdf
《ASTM D5293-2010e1 Standard Test Method for Apparent Viscosity of Engine Oils and Base Stocks Between &x2013 5 and &x2013 35&x00B0 C Using Cold-Cranking Simulator《使用冷启动模拟器测定机油表面粘度和x.pdf》由会员分享,可在线阅读,更多相关《ASTM D5293-2010e1 Standard Test Method for Apparent Viscosity of Engine Oils and Base Stocks Between &x2013 5 and &x2013 35&x00B0 C Using Cold-Cranking Simulator《使用冷启动模拟器测定机油表面粘度和x.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5293 101Standard Test Method forApparent Viscosity of Engine Oils and Base StocksBetween 5 and 35C Using Cold-Cranking Simulator1This standard is issued under the fixed designation D5293; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUpdated Table 1 and 10.6.5 editorially in November 2011.1. Scope*1.1 This test method covers t
3、he laboratory determination ofapparent viscosity of engine oils and base stocks by coldcranking simulator (CCS) at temperatures between 5 and35C at shear stresses of approximately 50 000 to 100 000 Paand shear rates of approximately 105to 104s1for viscositiesof approximately 900 to 25 000 mPas. The
4、range of aninstrument is dependent on the instrument model and softwareversion installed. Apparent Cranking Viscosity results by thismethod are related to engine-cranking characteristics of engineoils.1.2 A special procedure is provided for measurement ofhighly viscoelastic oils in manual instrument
5、s. See AppendixX2.1.3 Procedures are provided for both manual and automateddetermination of the apparent viscosity of engine oils using thecold-cranking simulator.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This stan
6、dard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific warningstatements
7、are given in Section 8.2. Referenced Documents2.1 ASTM Standards:2D2162 Practice for Basic Calibration of Master Viscometersand Viscosity Oil StandardsD2602 Test Method for Apparent Viscosity of Engine Oilsat Low Temperature Using the Cold-Cranking Simulator3D4057 Practice for Manual Sampling of Pet
8、roleum andPetroleum Products2.2 ISO Standard:ISO 17025 General Requirements for the Competence ofTesting and Calibration Laboratories43. Terminology3.1 Definitions:3.1.1 Newtonian oil or fluid, none that exhibits a constantviscosity at all shear rates.3.1.2 non-Newtonian oil or fluid, none that exhi
9、bits aviscosity that varies with changing shear stress or shear rate.3.1.3 viscosity, h, nthe property of a fluid that determinesits internal resistance to flow under stress, expressed by:h5tg(1)where:t = the stress per unit area, andg = the rate of shear.3.1.3.1 DiscussionIt is sometimes called the
10、 coefficient ofdynamic viscosity. This coefficient is thus a measure of theresistance to flow of the liquid. In the SI, the unit of viscosityis the pascal-second; for practical use, a submultiple(millipascal-second) is more convenient and is customarilyused. The millipascal second is 1 cP (centipois
11、e).3.2 Definitions of Terms Specific to This Standard:3.2.1 apparent viscosity, nthe viscosity obtained by use ofthis test method.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Prope
12、rties.Current edition approved May 1, 2010. Published August 2010. Originallyapproved in 1991. Last previous edition approved in 2009 as D529309. DOI:10.1520/D5293-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
13、Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, N
14、Y 10036, http:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.1.1 DiscussionSince many engine oils are non-Newtonian at low temperature, apparent vis
15、cosity can varywith shear rate.3.2.2 calibration oils, noils with known viscosity andviscosity/temperature functionality that are used to define thecalibration relationship between viscosity and cold-crankingsimulator rotor speed.3.2.3 check oil, na batch of test oil used to monitormeasurement perfo
16、rmance.3.2.4 test oil, nany oil for which the apparent viscosity isto be determined by use of this test method.3.2.5 viscoelastic oil, na non-Newtonian oil or fluid thatclimbs up the rotor shaft during rotation.4. Summary of Test Method4.1 An electric motor drives a rotor that is closely fittedinsid
17、e a stator. The space between the rotor and stator is filledwith oil. Test temperature is measured near the stator inner walland maintained by removing heat with a controlled process tomaintain a constant stator temperature during test. The speed ofthe rotor is calibrated as a function of viscosity.
18、 Test oilviscosity is determined from this calibration and the measuredrotor speed.5. Significance and Use5.1 The CCS apparent viscosity of automotive engine oilscorrelates with low temperature engine cranking. CCS appar-ent viscosity is not suitable for predicting low temperature flowto the engine
19、oil pump and oil distribution system. Enginecranking data were measured by the Coordinating ResearchCouncil (CRC) L-495test with reference oils that had viscosi-ties between 600 and 8400 mPas (cP) at 17.8C and between2000 and 20 000 mPas (cP) at 28.9C. The detailed relation-ship between this engine
20、cranking data and CCS apparentviscosities is in Appendixes X1 and X2 of the 1967 T editionof Test Method D26026and CRC Report 409.5Because theCRC L-49 test is much less precise and standardized than theCCS procedures, CCS apparent viscosity need not accuratelypredict the engine cranking behavior of
21、an oil in a specificengine. However, the correlation of CCS apparent viscositywith average CRC L-49 engine cranking results is satisfactory.5.2 The correlation between CCS and apparent viscosityand engine cranking was confirmed at temperatures between 1and 40C by work on 17 commercial engine oils (S
22、AE grades5W, 10W, 15W, and 20W). Both synthetic and mineral oilbased products were evaluated. See ASTM STP 621.75.3 A correlation was established in a low temperatureengine performance study between light duty engine startabil-ity and CCS measured apparent viscosity. This study used ten1990s engines
23、 at temperatures ranging from 5 down to 40Cwith six commercial engine oils (SAE 0W, 5W, 10W, 15W,20W, and 25W).85.4 The measurement of the cranking viscosity of basestocks is typically done to determine their suitability for use inengine oil formulations.Asignificant number of the calibrationoils fo
24、r this method are base stocks that could be used in engineoil formulations.6. Apparatus6.1 Two types of apparatus are described for use in this testmethod: the manual cold-cranking simulator (see AppendixX1) and the automated CCS (see 6.2 and 6.3).6.2 Automated CCS,9consisting of a direct current (d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD52932010E1STANDARDTESTMETHODFORAPPARENTVISCOSITYOFENGINEOILSANDBASESTOCKSBETWEENX20135ANDX201335X00B0CUSINGCOLDCRANKINGSIMULATOR

链接地址:http://www.mydoc123.com/p-519398.html