ASTM D3926-2005(2011) Standard Test Methods for Percent Solids in Titanium Dioxide Slurries《钛粉(二氧化钛)稀浆中固体百分比标准试验方法》.pdf
《ASTM D3926-2005(2011) Standard Test Methods for Percent Solids in Titanium Dioxide Slurries《钛粉(二氧化钛)稀浆中固体百分比标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3926-2005(2011) Standard Test Methods for Percent Solids in Titanium Dioxide Slurries《钛粉(二氧化钛)稀浆中固体百分比标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3926 05 (Reapproved 2011)Standard Test Methods forPercent Solids in Titanium Dioxide Slurries1This standard is issued under the fixed designation D3926; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of theweight percent of solids in aqueous slurries of titanium dioxidepigments
3、by either the use of a gravity-convection oven(Method A), infrared radiation moisture analyzer (Method B),or a microwave drying system (Method C).1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This test standard does no
4、t purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standard
5、s:2D1193 Specification for Reagent Water3. Summary of Test Method3.1 Oven Method:3.1.1 Slurry is weighed by difference into a tared aluminumfoil dish, dried at 105C in an oven for 1 h, cooled in adesiccator, and weighed.3.2 Infrared Method:3.2.1 Slurry is dried under infrared lamps for a specifiedti
6、me and temperature. The results are obtained directly formthe units display panel.3.3 Microwave Method:3.3.1 2 to4gofslurry is placed between two glass fiberpads and dried in a microwave drying system. The results areobtained directly form the units display panel.4. Significance and Use4.1 These tes
7、t methods are intended as a quick and reliableprocedure for measuring the titanium dioxide pigment contentof aqueous slurries. Included with the pigment content in thepercent solids are the various nonvolatile additives used inpreparing a stable slurry. Because the aluminum and silicaoxide treatment
8、s on the more highly treated titanium dioxidepigments may change somewhat with prolonged drying, in theoven method the solids of the slurry are considered dry afterheating at 105C for 60 to 65 min. The high temperatureassociated with the infrared moisture analyzer may also effecta change in the alum
9、inum and silica oxide treatment on highlytreated TiO2products. Therefore, care in selection of time andtemperature are critical to obtain accurate results with theinfrared method. With the short duration of test associated withthe microwave drying system, overdrying is not a concern.5. Apparatus5.1
10、Oven Method:5.1.1 OvenLaboratory oven capable of maintaining atemperature of 105 6 2C (Note 1). The oven may be agravity-convection type or an oven with a low velocity, forceddraft. An oven with a high-velocity, forced-draft air change,commonly used for baking finishes, is not suitable.NOTE 1The tem
11、perature in the oven must be constantly monitored.Many older ovens will no longer maintain 62C; some will maintain thistolerance for a while but occasionally the thermostat will “stick” and thetemperature will vary considerably.5.1.2 BalanceLaboratory analytical balance, accurate to0.1 mg, with 1-g
12、optical readout range for fast weighing.NOTE 2Periodically check the accuracy of the 1-g optical scale of thebalance by use of a known 1-g weight; adjust the balance if needed. Thezero adjustment of the optical scale needs to be checked at least every hourroutinely and immediately if there is any po
13、ssibility of a spill havingoccurred on the balance.5.1.3 DesiccatorStandard laboratory desiccator utilizingan indicating drying medium.5.2 Infrared Method:5.2.1 Infrared Moisture AnalyzerAutomated moistureanalyzer combining infrared drying technology and a precisionanalytical balance in a single uni
14、t.1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.31 on Pigment Specifications.Current edition approved June 1, 2011. Published June 2011. Originallyapproved in 1980. l
15、ast previous edition approved in 2005 as D3926 05. DOI:10.1520/D3926-05R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
16、 ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 Microwave Method:5.3.1 Microwave Drying SystemA National RecognizedTesting Laboratory (NRTL) approved 630 W microwave dry-ing system with 50 g, 0.1 mg readability inte
17、rnal balance tomeasure moisture/solids from 0.1 to 99.99 %.6. Reagents and Materials6.1 Oven Method:6.1.1 Purity of WaterUnless otherwise indicated, refer-ences to water shall be understood to mean reagent waterconforming to Type II of Specification D1193.6.1.2 Aluminum Foil DishDisposable aluminum
18、foildishes, approximately 60-mm diameter by 18 mm high, 1 to 2g in weight.6.1.3 Disposable Syringe or DropperDisposable 2 or3-mL syringes or 2 to 5-mL droppers.6.2 Infrared Moisture Analyzer:6.2.1 Sample Holders appropriate for the Infrared MoistureAnalyzer.6.2.2 Disposable Syringe (2 or 3-mL) or Dr
19、opper.6.3 Microwave Drying System.6.3.1 Sample Holders appropriate for the Microwave Dry-ing System.6.3.2 Disposable Syringe (2 to 3-mL) or Dropper.7. Procedures7.1 Method A, Oven:7.1.1 Weigh two new, empty aluminum dishes each to 0.1mg. For each dish, this is W1. With a syringe add 2 mL of waterto
20、each dish.7.1.2 Shake or stir the slurry sample until it is homogeneousand free of any settle material. If the container is transparent oftranslucent, the absence of settled material sticking to thebottom of the container can be ascertained visually. Otherwiseinsert a spatula or the like to make sur
21、e there is no settledmaterial.7.1.3 Immediately withdraw 0.4 to 0.8 g of slurry in a new,empty disposable syringe or dropper. The specified amount canbe estimated by a prior trial in another syringe or dropper. Wipeoff the slurry from the outside of the syringe or dropper with aclean, absorbent pape
22、r. Cover the sample bottle. Weigh thesyringe or dropper and slurry to 0.1 mg. This is W2.7.1.4 Transfer the contents of the dropper into one of theweighed aluminum dishes. Add the slurry dropwise, gentlyshaking the dish to disperse the test specimen in the water.When no additional slurry can be tran
23、sferred from the dropper,reweigh to 0.1 mg the dropper with any residual materialinside. This is W3.7.1.5 Shake the sample of slurry briefly and withdraw asecond 0.4 to 0.8 g of slurry in another new dropper. Weigh andtransfer contents as in 7.1.3 and 7.1.4 to the second weighedaluminum dish.7.1.6 P
24、lace the two dishes and contents directly onto themetal shelf in the oven at 105 6 2C for 60 to 65 min. Do notdry in the oven longer than the specified 65 min.7.1.7 Remove the dishes from the oven, cool in the desic-cator for 10 to 60 min, remove one dish at a time, and weighimmediately to the neare
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD392620052011STANDARDTESTMETHODSFORPERCENTSOLIDSINTITANIUMDIOXIDESLURRIES 钛粉二 氧化 钛稀浆中 固体 百分比 标准 试验

链接地址:http://www.mydoc123.com/p-515823.html