ASTM D2945-1990(2003)e1 Standard Test Method for Gas Content of Insulating Oils《绝缘油的气体含量的试验方法》.pdf
《ASTM D2945-1990(2003)e1 Standard Test Method for Gas Content of Insulating Oils《绝缘油的气体含量的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2945-1990(2003)e1 Standard Test Method for Gas Content of Insulating Oils《绝缘油的气体含量的试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2945 90 (Reapproved 2003)e1Standard Test Method forGas Content of Insulating Oils1This standard is issued under the fixed designation D 2945; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEThe metric value for the inside diameter of vinyl tubing in Fig. 1 was corrected editorially in December 2003.1. Scope1.1 This test metho
3、d covers the determination of the gascontent of electrical insulating oils of low and mediumviscosities in the general range of 100 SUS and below at 100F(37.8C), and is suitable for field or laboratory use.NOTE 1For testing insulating oils with viscosities above 100 SUS, seeTest Method D 831. For in
4、dividual gas concentrations, see MethodD 3612.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regul
5、atory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 831 Test Method for Gas Content of Cable and CapacitorOilsD 3612 Test Method for Analysis of Gases Dissolved inElectrical Insulating Oil by Gas ChromatographyD 3613 Practice for Sampling Insulating Liquids for GasAnalysis an
6、d Determination of Water Content3. Summary of Test Method3.1 This test method consists essentially of allowing oil toflow into an evacuated chamber as a thin film so that the oil isthoroughly exposed to the vacuum, allowing free volatilizationof the gaseous component. The system is brought back toat
7、mospheric pressure, and the evolved gases measured. Fromthe volume of oil degassed in the chamber and the volume ofreleased gas, the percent gas content may be estimated. Theapparatus used produces the necessary vacuum without resort-ing to use of a vacuum pump. This test method partiallydegases the
8、 oil. The degree of degasification varies with thesolubility of each gas in the oil.4. Significance and Use4.1 In filling electrical apparatus, it is desirable to use lowgas content transformer oil in order to prevent foaming and toavoid air pockets that might result in gaseous ionization. Thisproce
9、dure provides a simple method to measure the gas contentof the oil, and may be used as a factory-control test and as acontrol or functional test in installation and maintenance workby utilities.5. Apparatus5.1 Dissolved Gas Content AnalyserFig. 1 shows theassembled instrument, not drawn to scale, to
10、 permit magnifi-cation of small details. A borosilicate glass gas buret, 100-mLcapacity, graduated in15-mL divisions, serves as a vacuumchamber. A three-way stopcock, 120 bore with TFE-fluorocarbon plug, 3 stem, 2-mm bore is fused to the buret orjoined by a vinyl sleeve so that the joint is vacuum t
11、ight.5.1.1 Rubber Vacuum TubingAbout 1200 mm of 8-mmrubber vacuum tubing is securely fastened with a 20-mmHoffman pinch clamp to the lower tip of the buret, while theother end is secured to a 250-mL capacity leveling bulb.5.1.2 Stubs 20 Gage NeedleA short section, about 40 mmlong, is cut and cemente
12、d to the three-way stopcock, Fig. 2.This serves to accommodate the vinyl tubing attached to thesyringe.All the glassware should be clamped to a suitable 1500by 700 by 20-mm mounting board with rubber-covered wall-type clamps.5.1.3 Metal Rod, 12 mm, 1500 mm long, fitted with anadjustable leveling bul
13、b support is fastened to the woodenapparatus mounting board as in 5.1.2.5.2 Syringe Assembly (see Fig. 3)A 50-mL Luer syringewith 5-mL subdivisions or a 5-mL Luer syringe with15-mLsubdivisions is fitted with a 150-mm length of 0.8-mm insidediameter capillary vinyl tubing. An upper and lower collar o
14、fplastic or metal is attached to the syringe to support the rubber1This test method is under the jurisdiction of ASTM Committee D27 onElectrical Insulating Liquids and Gases and is the direct responsibility of Subcom-mittee D27.03 on Analytical Tests.Current edition approved Feb. 23, 1990. Published
15、 April 1990. Originallypublished as D 2945 71. Last previous edition D 2945 84.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page o
16、nthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.bands required to create positive pressure in the syringe.A20-mm Hoffman pinch clamp is used on the capillary tubingafter sampling.5.3 Oil Sampler (see Fig. 3)A 3.2-mm
17、 tee is fitted with asyringe needle stem in one arm and a short length of 6.4-mm.Vinyl tubing is attached to the other arm. During sampling, thetee is attached to the sampling valve and the vinyl capillarytubing of the syringe assembly is attached to the needle of thetee.1 gas buret, capacity 100 mL
18、, graduated in15-mL divisions1 stopcock, 120 bore with TFE fluorocarbon plug, 3 stems, 2-mm bore1 leveling bulb, capacity 250 mL1 beaker, capacity 250 mL1200 mm (4 ft) vacuum rubber tubing, 8-mm (316-in.) inside diameter2 rubber tubing clamps, adjustable, cadmium-plated steel2-pinch clamps, Hoffman
19、swivel jaw, screw compressor,34 by 1 in. for vinyl tubing for 5 and 50-mL syringes1 pinch clamp, Hoffman screw compressor for rubber tubing,34 by1in.6 clamps, wall type with wood screw to support buret, stopcock, and rod1 leveling bulb support, adjustable, Fisher-Castaloy-R, self-locking1 rod, diame
20、ter 12 mm (12 in.), length 1500 mm (58 in.)1 syringe, Luer, resistance glass, 50 mL, subdivisions 5 mL1 syringe, Luer, resistance glass, 5 mL, subdivisions15 mLVinyl tubing, 1.6-mm (116-in.) inside diameter, wall thickness 1.3 mm (132 in.), length 150 mm (6 in.)4.5 kg (10 lb) mercury1 needle, 50 mm
21、long, Stubbs gage 201 wooden board 1500 by 700 by 20 mm (58 by 28 by78 in.)Components for Gas-Content ApparatusFIG. 1 Dissolved Gas Content AnalyserFIG. 2 Detail of Needle InletD 2945 90 (2003)e125.4 Mercury ReservoirA250-mL capacity leveling bulb isfilled with 4.5 kg (10 lb) of mercury.6. Sampling6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD294519902003E1STANDARDTESTMETHODFORGASCONTENTOFINSULATINGOILS 绝缘油 气体 含量 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-513830.html