ASTM D20-2003 Standard Test Method for Distillation of Road Tars《路面焦油蒸馏的标准试验方法》.pdf
《ASTM D20-2003 Standard Test Method for Distillation of Road Tars《路面焦油蒸馏的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D20-2003 Standard Test Method for Distillation of Road Tars《路面焦油蒸馏的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 20 03Standard Test Method forDistillation of Road Tars1This standard is issued under the fixed designation D 20; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in parentheses indi
2、cates the year of last reapproval. A superscriptepsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the distillation of road tars.1.2 This standard does no
3、t purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standard
4、s:E 1 Specification for ASTM Thermometers23. Summary of Test Method3.1 A 100-g sample is distilled at a controlled rate from a300-mL flask into tared receivers. The masses of distillatefractions at a series of specified temperatures and of residue atthe maximum specified temperature are determined.
5、If desired,the residue and distillates may be used for further testing.4. Significance and Use4.1 The distillation test separates tar into fractions accordingto a series of specified temperatures.5. Apparatus5.1 FlaskA side-arm distillation flask, as shown in Fig. 1,conforming to the following dimen
6、sions:Diameter of bulb, outside, mm 86.0 6 1.5Diameter of neck, inside, mm 22.0 6 1.0Diameter of side-arm, inside, mm 10.0 6 0.5Height of flask, outside, mm 131.0 6 1.5Vertical distance, bottom of bulb, outside, to hori-zontaltangent at side-arm, inside, mm93.0 6 1.5Length of side-arm, mm 220 6 5Ang
7、le of side-arm, deg 75 6 2Thickness of side-arm wall, mm 1.0 to 1.55.2 Condenser Tube A tapered glass condenser, as shownin Fig. 2 and Fig. 3, having the following dimensions:Outside diameter of small end, mm 12.5 6 1.5Outside diameter of large end, mm 28.5 6 3.0Length, mm 360 6 4Length of uniformly
8、 tapered part, mm 100 6 55.3 Source of Heat A heat source consisting of a bunsenor meker-type burner (Note 1) or an electric heater. The electricheater3shall have an output variable of 750 W and an upperrefractory with dimensions as shown in Fig. 4. The temperatureof the heater shall be controlled b
9、y a variable transformer orrheostat suitable for the voltage used, and shall be fitted with aclamp for mounting on a vertical support rod.NOTE 1An artificial gas model used with natural gas has been foundto give a uniform and easily controlled source of heat.5.4 Flask Shield and Cover for Flame Dist
10、illationA steelshield (preferably stainless) lined with 3-mm Transite board,non-asbestos, with two-part cover made from 6-mm Transiteboard of the form and dimensions shown in Fig. 5.5.5 Flask Shield and Cover for Electric-HeaterDistillationA steel shield (preferably stainless) fitted withmica window
11、s, and a cover of the same construction and1This method is under the jurisdiction of ASTM Committee D04 on Road andPaving Materials and is the direct responsibility of Subcommittee D04.43 onSpecifications and Tests for Tar and Tar Products.Current edition approved July 10, 2003. Published September
12、2003. Originallyapproved in 1911. Last previous edition approved in 1999 as D 20 99.2Annual Book of ASTM Standards, Vol 14.03.3The Precision Ful-Kontrol 750-W heater with built-in variable transformercontrol, available from Precision Scientific Co., Chicago, IL, has been foundsatisfactory. This heat
13、er is only available for 115 V. 50/60 Hz.FIG. 1 Distillation Flask1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.dimensions as those for flame distillation (5.4) except for theheight of the shield (see Fig. 6).5.6 Gauze for Flame Di
14、stillationTwo sheets of 1.0-mmopening wire gauze made of 0.56-mm diameter nickel-chromium wire measuring a minimum of 125 mm in diameteror (125 by 125-mm) square.5.7 Burner Chimney for Flame DistillationConstruct acylindrical metal shield approximately 100 mm high, 95 to 105FIG. 2 Apparatus Assembly
15、 for Flame DistillationFIG. 3 Apparatus Assembly for Electric Heater DistillationFIG. 4 Upper Part of Electric HeaterD20032mm in diameter, and having a peephole 25 mm in diametercentered about 32 mm below the ring support. The top of theshield shall be flanged to permit its being suspended from ther
16、ing support.5.8 ReceiversErlenmeyer flasks or beakers having anominal capacity of 50 to 125 mL, and tared to the nearest 0.1g.5.9 Balance and Masses, accurate to 0.1 g.5.10 ThermometerAn ASTM High Distillation Thermom-eter having a range from 2 to + 400C and conforming to therequirements for Thermom
17、eter 8C as prescribed in Specifica-tion E 1.6. Preparation of Sample6.1 Thoroughly stir or otherwise mix the sample immedi-ately before removing the portion for testing, to ensure thatsuch portion will be representative of the sample. If warming isnecessary, take care to avoid loss of volatile mater
18、ial.7. Preparation of Apparatus7.1 Assemble the apparatus as follows (see Fig. 2 and Fig.3):7.1.1 Suspend the burner chimney by its flange from thesupport ring, place the specified two sheets of flat wire gauzeon the burner chimney, and place the flask shield on the uppersheet of gauze. In case the
19、electric heater is used, attach theheater to a vertical support so that at the end of the distillationit can be lowered at least 150 mm. Place the upper refractoryon the heater with the larger opening facing upwards. Set theflask shield on the upper refractory.7.1.2 Inset the thermometer through a n
20、ew and rolled selectquality regular-length cork of suitable size. Position the ther-mometer and cork in the neck of the flask so that the cork fitstightly and the bottom of the cork is from 23 to 28 mm abovethe lowest point of the junction between the side-arm and theneck of the flask. Then adjust t
21、he thermometer in the cork sothat the top of the bulb is level with the lowest point of thejuncture between the side-arm and the neck of the flask. Alignthe stem of the thermometer on the axis of the bulb through theneck of the flask.7.1.3 When using the flame distillation apparatus, place theflask
22、in the flask shield with its bulb resting on the gauze.Position the burner so that it is directly beneath the point wherethe bulb of the flask contacts the gauze. If the electric heater isused, place the flask in the flask shield and support the flask sothat its bottom is between 4 and 7 mm above th
23、e heating coils.7.1.4 Connect the condenser tube to the side-arm of the flaskwith a tight cork joint, having the side-arm project 30 to 50 mmthrough the cork. The distance from the neck of the flask to theoutlet end of the condenser tube shall be between 500 and 600mm. Support the condenser tube in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD202003STANDARDTESTMETHODFORDISTILLATIONOFROADTARS 路面 焦油 蒸馏 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510820.html