ASTM C371-1989(2003) Standard Test Method for Wire-Cloth Sieve Analysis of Nonplastic Ceramic Powders《非塑性陶瓷粉末的金属丝筛分析的标准试验方法》.pdf
《ASTM C371-1989(2003) Standard Test Method for Wire-Cloth Sieve Analysis of Nonplastic Ceramic Powders《非塑性陶瓷粉末的金属丝筛分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C371-1989(2003) Standard Test Method for Wire-Cloth Sieve Analysis of Nonplastic Ceramic Powders《非塑性陶瓷粉末的金属丝筛分析的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 371 89 (Reapproved 2003)Standard Test Method forWire-Cloth Sieve Analysis of Nonplastic Ceramic Powders1This standard is issued under the fixed designation C 371; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the particlesize distribution of nonplastic ceramic powders such
3、as alu-mina, silica, feldspar, pyrophyllite, nepheline syenite, talc,titanates, and zircon using wire cloth sieves.1.2 Materials containing a large amount of fines, containingagglomerates, or that are nonfree-flowing, are wet-sieved toremove excessive fines or to disperse agglomerates beforeperformi
4、ng the test. This technique is not applicable to mate-rials that are, to any degree, water soluble.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and healt
5、h practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 322 Practice for Sampling Ceramic Whiteware Clays2E 11 Specification for Wire Cloth and Sieves for TestingPurposes23. Significance and Use3.1 Sieve analyses are carried out
6、 to determine the particlesize distribution of powders which, in turn, are used to qualifythose materials as to their usefulness in the process underconsideration. Since particle size analyses have only relativesignificance, the results should be considered only where theycorrelate with process char
7、acteristics. The parameter that isbeing measured in this test is the amount of material that willpass through a cloth having theoretically square openings. Itmust be remembered that all the holes are not square, noruniform in size, and the question of whether a given particlewill go through is a sta
8、tistical one. Since each particle sizeanalysis method measures a unique physical parameter, theresults from one method may not agree with those fromanother. Particle size distributions play a role in such propertiesas bulk density, dustiness, and handling characteristics. Careshould be taken, howeve
9、r, when interpretations are made fromone or two points (sieves) on the distribution curve.4. Apparatus4.1 Balance, having a sensitivity of 0.05 g.4.2 Sieves, clean, unblinded, 205 mm (8 in.) in diameter,and conforming to Specification E 11. At all times they shall becertified by, or shall be calibra
10、ted with sieves certified by, theNational Institute of Standards and Technology. For wet-sieving, use full-height 50-mm (2-in.) sieves; these sieves andpan may be used for dry-sieving also. Half-height 25-mm(1-in.) sieves and pan shall be used for dry-sieving only. Thesieves to be used may range fro
11、m 45 m (No. 325) through 212m (No. 70).4.3 Drying Pans, about 205 mm (8 in.) in diameter and 25or 50 mm (1 or 2 in.) high.4.4 DryerFor drying, the use of an oven maintainedautomatically at 100 to 110C is recommended.4.5 Mechanical Shaking Device3The shaking device shallbe such as to produce a latera
12、l and vertical motion of the sieve,accompanied by a jarring action so as to keep the samplemoving continuously over the surface of the sieve.4.6 In wet-sieving, the water should be slightly above roomtemperature (for example, a hot-cold mixer tap) and should besupplied by means of a fixed or hand-he
13、ld spray.5. Sampling5.1 Unit for SamplingEach carload shall be considered aunit for sampling.5.2 Gross Sample (See Practice C 322)In collecting thegross sample from a carload shipped in bags, select a numberof bags equivalent to not less than 1 % of the total number ofbags in the car. Bags taken for
14、 sampling shall be from locationsevenly distributed, horizontally and vertically, throughout thecar. The gross sample shall consist of equal increments of notless than 227 g (0.5 lbs) from each of the bags taken forsampling. In collecting the gross sample from a carload1This method is under the juri
15、sdiction of ASTM Committee C21 on CeramicWhitewares and Related Products and is the direct responsibility of SubcommitteeC21.04 on Raw Materials.Current edition approved Oct 1, 2003. Published October 2003. Originallyapproved in 1955. Last previous edition approved in 1999 as C 371 89 (1999).2For re
16、ferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The Tyler Ro-Tap mechanical shaking device, available from W.S. Tyl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC37119892003STANDARDTESTMETHODFORWIRECLOTHSIEVEANALYSISOFNONPLASTICCERAMICPOWDERS 塑性 陶瓷 粉末 金属丝 筛分

链接地址:http://www.mydoc123.com/p-466398.html