《ASTM C1601-2014 Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces《现场测定砌筑墙表面渗水性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1601-2014 Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces《现场测定砌筑墙表面渗水性的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1601 11C1601 14Standard Test Method forField Determination of Water Penetration of Masonry WallSurfaces1This standard is issued under the fixed designation C1601; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the field determination of water penetration of a masonry wall surface under specific w
3、ater flowrate and air pressure conditions. This test is intended for use on any masonry wall surface that can be properly instrumented andtested within the requirements of this standard.1.2 This test method is not identical to and the results are not the same as the laboratory standard Test Method E
4、514.1.3 This test method evaluates the surface water penetration, which is not the same as through-wall water penetration evaluatedby Test Method E514.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units tha
5、t are provided for information only and are not considered standard.1.5 This standard may involve hazardous materials, operations, or equipment. This standard does not purport to address all ofthe safety problems associated with its use. It is the responsibility of the user of this standard to estab
6、lish appropriate safety andhealth practices and determine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1232 Terminology of MasonryE514 Test Method for Water Penetration and Leakage Through Masonry3. Terminology3.1 Definitions:3.1.1 dampness, nv
7、isual change in the appearance of a material due to the presence of water.3.1.2 surface water penetration, nwater that passes through the exterior face of the masonry.3.1.3 through-wall water penetration, nsurface water that penetrates through a wall and exits the interior face of the masonry.3.1.4
8、water penetration, nwater that passes into or through the masonry.3.1.5 wind-driven rain, nrain water that is directed against the surface of the wall by wind.3.2 For additional definitions of terms used in this test method, refer to Terminology C1232.4. Significance and Use4.1 This non-destructive
9、test method contains procedures and equipment requirements to quantitatively determine the surfacepenetration of water at a single location on a masonry wall. It is not designed to determine the overall water penetration and leakageof a masonry system.4.2 Excessive water penetration of masonry may d
10、egrade masonry wall performance with respect to thermal conductivity,durability, efflorescence, staining, corrosion of embedded metal items, and water leakage.1 This test method is under the jurisdiction ofASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommit
11、tee C15.04 on Research.Current edition approved Dec. 15, 2011Feb. 1, 2014. Published January 2012February 2014. Originally approved in 2004. Last previous edition approved in 20102011as C1601 10.C1601 11. DOI: 10.1520/C1601-11.10.1520/C1601-14.2 For referencedASTM standards, visit theASTM website, w
12、ww.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of w
13、hat changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered t
14、he official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 This test may be used to evaluate masonry walls in-situ or for field mock-up testing. Common app
15、lications of this methodhave been comparison of water penetration rates of walls before and after repairs, and testing the efficacy of coatings. Alternativeprocedures are also provided to simulate the effect of local climatology on water penetration of masonry wall surfaces.4.4 The outer surface of
16、all masonry walls will experience water penetration when subjected to wind-driven rain. The resistanceto water penetration is dependent on materials, workmanship, design, and maintenance. Some wall types accommodate largevolumes of water penetration, without deleterious effects, through the presence
17、 of properly designed and installed drainage systemsincluding flashing and weep holes. Use of this standard without consideration of the overall wall system may lead to incorrectconclusions regarding performance.4.5 It is the intent of this standard that a sheet of water be developed and maintained
18、on the wall surface during testing. In somecases, due to the surface texture of the masonry, the application of a coating, or other factors, a sheet of water will not consistentlyform. In those cases, results of this test method will likely be inaccurate.4.6 This test method is similar to but distin
19、ct from the laboratory Test Method E514. This field test method is designed to testin-situ walls. E514 laboratory test method is designed to test laboratory wall specimens. This test method determines waterpenetration of the masonry at its surface. Test Method E514 measures the water that has penetr
20、ated into and through the masonryspecimen and is collected. Results from Test Method C1601 and Test Method E514 are not the same.5. Apparatus5.1 Test ChamberUse a test chamber similar to that shown in Fig. 1. Provide a rectangular opening with a minimum area of12 ft2 (1.08 m2) with a minimum dimensi
21、on of 24 in. (0.6 m) for each side of the opening (Note 1). Seal the contact surface betweenthe frame of the chamber and the test area to prevent loss of water and maintain air pressure. Cover the face of the chamber witha tough, transparent material capable of withstanding the test pressure (Note 2
22、). Provide a 34-in. (19-mm) diameter,corrosion-resistant, water spray pipe with a single line of 0.04-in. (1.0-mm) diameter holes spaced 1 in. (25 mm) apart, startingwithin 1 in. (25 mm) of each end (Note 3). Position the water spray pipe within the chamber so that the water impinges the wallperpend
23、icular to the wall not more than 1.5 in. (40 mm) below the interior top of the test chamber.NOTE 1A size of 36 in. (0.9 m) wide and 48 in. (1.2 m) high is common.NOTE 2Transparent plastic sheets 316 to 14 inch (5 to 6 mm) thick have been shown to perform well. Plexiglas and Lexan are two products th
24、athave been used.NOTE 3Clean-outs at the end of the spray bar to facilitate cleaning the spray bar are common.FIG. 1 Water Surface Penetration Test SystemC1601 1425.2 Fixtures and Appurtenances to ChamberFixtures and appurtenances to the chamber include an air line with manometeror pressure gauge ab
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16012014STANDARDTESTMETHODFORFIELDDETERMINATIONOFWATERPENETRATIONOFMASONRYWALLSURFACES 现场 测定 砌筑

链接地址:http://www.mydoc123.com/p-465261.html