1、Designation: C 1149 06e1Standard Specification forSelf-Supported Spray Applied Cellulosic Thermal Insulation1This standard is issued under the fixed designation C 1149; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTETable 2 was editorially corrected in May 2007.1. Scope1.1 The specification covers the physical properties ofself-supported s
3、pray applied cellulosic fibers intended for useas thermal insulation or an acoustical absorbent material, orboth.1.2 This specification covers chemically treated cellulosicmaterials intended for pneumatic applications where tempera-tures do not exceed 82.2C (180F) and where temperatureswill routinel
4、y remain below 65.6C (150F).1.2.1 Type IMaterial applied with liquid adhesive andsuitable for either exposed or enclosed applications.1.2.2 Type IIMaterials containing a dry adhesive that isactivated by water during installation and intended only forenclosed or covered applications.1.3 This is a mat
5、erial specification only and is not intendedto deal with methods of application that are supplied by themanufacturer.1.4 The values stated in SI units are to be regarded asstandard. The inch-pound units given in parentheses are forinformation only.1.5 This standard does not purport to address all of
6、 thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relati
7、ng to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 739 Specification for Cellulos
8、ic Fiber Loose-Fill ThermalInsulationC 1363 Test Method for Thermal Performance of BuildingMaterials and Envelope Assemblies by Means of a HotBox ApparatusE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 605 Test Methods for Thickness and Density of SprayedFire-Resistive Mat
9、erial (SFRM) Applied to StructuralMembersE 736 Test Method for Cohesion/Adhesion of Sprayed Fire-Resistive Materials Applied to Structural MembersE 759 Test Method for Effect of Deflection on SprayedFire-Resistive Material Applied to Structural MembersE 859 Test Method for Air Erosion of Sprayed Fir
10、e-Resistive Materials (SFRMs) Applied to Structural Mem-bers3. Terminology3.1 DefinitionsDefinitions in Terminology C 168 shallapply in this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 constant massno change in successive weighings inexcess of 0.5 % of specimen mass taken
11、at 4-h intervals unlessotherwise specified. Specimen should not be always increasingin weight or decreasing in weight.3.2.2 curedthe state of the finished product after it hasachieved constant mass.3.2.3 curingthe process in which the liquid vehicle isremoved. Normally achieved in ambient building c
12、onditionswith forced air convection to hasten the evaporation process.3.2.4 prepared samplesamples prepared in accordancewith Section 5 and cured to constant mass prior to conductingthe specific tests. The prepared samples, after reaching constantmass, as defined in 3.2.1, shall have a density withi
13、n 610 % ofthe manufacturers recommended design density.3.2.5 self supportinga product that can be tested by thecriteria imposed by this specification and that will require nosupport other than itself or the substrate to which it is attached.1This specification is under the jurisdiction of ASTM Commi
14、ttee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved Dec. 1, 2006. Published December 2006. Originallyapproved in 1990. Last previous edition approved in 2002 as C 1149-02.2For referenced ASTM standards, vi
15、sit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
16、2959, United States.3.2.6 specimendefinition of specimen as used in thisspecification shall be the same as that for prepared sample in3.2.4.3.2.7 sprayed fiberchemically treated cellulosic materials,that are pneumatically conveyed and mixed with water oradhesive, or both, at the spray nozzle and bec
17、ome self-supporting when cured.4. Physical Properties4.1 Materials and Manufacture:4.1.1 The basic material shall consist of virgin or recycledwood based cellulosic fiber.4.1.2 Suitable chemicals shall be introduced to provideflame resistance, improved processing, adhesive/cohesiveproperties, and ha
18、ndling and application characteristics.4.1.3 The basic material shall be processed into a formsuitable for installation by pneumatic conveying equipmentand the simultaneous mixing with liquid at the spray nozzle.4.2 DensityType I and Type II samples shall be within610 % of the manufacturers stated v
19、alues when tested inaccordance with 6.1.4.3 Thermal ResistanceType I and Type II samples shallbe within 610 % of the manufacturers stated values whentested in accordance with 6.4.4.4 Surface Burning CharacteristicsType I and Type IIsamples shall have a maximum flame spread rating of 25 anda maximum
20、smoke developed rating of 50 when tested inaccordance with 6.2.4.5 Adhesive/Cohesive Strength:4.5.1 Type IThe applied material shall have a minimumadhesive/cohesive bond strength per unit area of five times theweight of the material under the test plate when tested inaccordance with Test Method E 73
21、6.4.5.2 Type IIThe applied product shall have a minimumadhesive/cohesive bond strength per unit area of two times theweight of the material under the test plate when tested inaccordance with Test Method E 736.4.6 Smoldering CombustionType I and Type II products,when tested in accordance with 6.5, sh
22、all have a weight loss nogreater than 15 % of the specimen weight and shall exhibit noevidence of flaming.4.7 Fungi ResistanceType I and Type II products, whentested in accordance with 6.6, shall not promote more fungalgrowth than the control in at least two of the three replicatespecimens. (See Spe
23、cification C 739, 1986 edition, paragraph5.4.)4.8 CorrosionType I and Type II products, when tested inaccordance with 6.7, shall demonstrate no perforations in the3-mil metal coupons when observed in close proximity to a40-W appliance light bulb. Notches extending less than 3 mminto the coupon edge
24、can be ignored.4.9 Moisture Vapor AbsorptionMoisture absorption ofType I and Type II products shall be no more than 15 % whentested in accordance with 6.8.4.10 OdorType I and Type II, applied products shall haveno strong, objectionable odor when tested in accordance with6.9.4.11 Flame Resistance Per
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC11492006E1STANDARDSPECIFICATIONFORSELFSUPPORTEDSPRAYAPPLIEDCELLULOSICTHERMALINSULATION 支撑 喷涂 纤维

链接地址:http://www.mydoc123.com/p-463543.html