ASTM A745 A745M-1994(2009) Standard Practice for Ultrasonic Examination of Austenitic Steel Forgings《奥氏体钢锻件的超声波检验的标准实施规程》.pdf
《ASTM A745 A745M-1994(2009) Standard Practice for Ultrasonic Examination of Austenitic Steel Forgings《奥氏体钢锻件的超声波检验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A745 A745M-1994(2009) Standard Practice for Ultrasonic Examination of Austenitic Steel Forgings《奥氏体钢锻件的超声波检验的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 745/A 745M 94 (Reapproved 2009)Standard Practice forUltrasonic Examination of Austenitic Steel Forgings1This standard is issued under the fixed designationA 745/A 745M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice2covers the standards and procedures forthe contact, pulse-echo ultrasonic examination of au
3、steniticsteel forgings by the straight or angle beam techniques, or both.1.2 This practice shall be used whenever the inquiry, pro-posal, contract, order, or specification states that austenitic steelforgings are to be subject to ultrasonic examination in accor-dance with Practice A 745/A 745M. Ultr
4、asonic examination ofnonmagnetic retaining ring forgings should be made to PracticeA 531/A 531M, not to this practice.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsy
5、stem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This practice and the applicable material specificationsare expressed in both inch-pound units and SI units. However,unless the order specifies the applicable “M” sp
6、ecificationdesignation SI units, the material shall be furnished toinch-pound units.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and
7、 determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3A 531/A 531M Practice for Ultrasonic Examination ofTurbine-Generator Steel Retaining RingsE 317 Practice for Evaluating Performance Characteristicsof Ultrasonic Pulse-Echo Testing Instrume
8、nts and Systemswithout the Use of Electronic Measurement InstrumentsE 428 Practice for Fabrication and Control of Metal, Otherthan Aluminum, Reference Blocks Used in UltrasonicTesting2.2 American Society for Nondestructive Testing Docu-ment:SNT-TC-1A Recommended Practice for NondestructivePersonnel
9、Qualification and Certification43. Ordering Information3.1 When this practice is to be applied to an inquiry orpurchase order, the purchaser shall furnish the followinginformation:3.1.1 Quality level of examination (see Section 12).3.1.2 Additional requirements to this practice.3.1.3 Applicability o
10、f supplementary requirements (seeSupplementary Requirements section).3.2 When specified, the manufacturer shall submit an ex-amination procedure for purchaser approval that shall include,but not be limited to, a sketch of the configuration as presentedfor ultrasonic examination showing the surfaces
11、to be scanned,scanning directions, notch locations and sizes (if applicable),extent of coverage (if applicable), and an instruction listingcalibration and inspection details and stage of manufacture.4. Apparatus4.1 An electronic, pulsed, reflection type of instrument shallbe used for this examinatio
12、n. The system shall have a mini-mum capability for operating at frequencies from 0.5 to 5.0MHz. Either video or r-f presentation is acceptable.4.2 The ultrasonic instrument shall provide linear presenta-tion (within 6 5 % of the signal height) for at least 75 % of thescreen height (sweep line to top
13、 of screen). This 5 % linearityis descriptive of the screen presentation of amplitude. Instru-ment linearity shall be verified in accordance with the intent ofPractice E 317.4.3 Instruments with incremental gain control (accurateover its useful range to 6 10 % of the nominal attenuationratio) shall
14、be used when possible to allow measurement ofsignals beyond the linear display range of the instrument.4.4 Search Units:1This practice is under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.06 on Steel Forgings
15、and Billets.Current edition approved April 1, 2009. Published April 2009. Originallyapproved in 1977. Last previous edition approved in 2003 as A 745/A 745M 94(2003).2For ASME Boiler and Pressure Vessel Code applications see related Specifi-cation SA-745/SA-745M in Section II of that Code.3For refer
16、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from the American Society for Nondestructive Testing, 1711 A
17、rlin-gate Lane, P.O. Box 28518, Columbus, OH 432280518.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.4.1 Search units having transducers of either quartz orother piezoelectric materials may be employed.4.4.2 The maximum nominal a
18、ctive area of 112 in.2970mm2 with12-in. 13 mm minimum to 118-in. 30 mmmaximum dimensions or34-in. 20 mm diameter minimumdimension shall be used for straight-beam scanning.4.4.3 Angle-beam scanning transducers shall have a nomi-nal active area of12 to 1 in.2325 to 650 mm2. The search unitused for ang
19、le-beam examination shall produce a beam angleof 30 to 70 in the material.4.4.4 Other search units, including frequencies other thanthose listed in Section 8 , may be used for evaluating andpinpointing indications of discontinuities.4.5 CouplantA suitable couplant having good wettingcharacteristics
20、shall be used between the transducer and theexamination surface. The same couplant shall be used forcalibration and examination.4.6 Reference Blocks:4.6.1 All ultrasonic standard reference blocks shall be inaccordance with the general guidelines of Practice E 428.However, absolute conformance to Pra
21、ctice E 428 is notmandatory due to the nature of the material covered by thispractice.4.6.2 The reference block grain size, as measured by therelative acoustic penetrability of the reference blocks, shouldbe reasonably similar to the forging under examination. How-ever, it must be recognized that la
22、rge austenitic forgings varyconsiderably in acoustic penetrability throughout their volumedue to variations in grain size and structure. Reference blocksshould be chosen that reasonably approximate the averagepenetrability of the forging under examination. Supplementaryblocks of coarser or finer gra
23、in may be used for evaluation ofindications as covered in Section 11.4.6.3 As an alternative method, where practicable, theappropriate size of reference hole (or holes) or notches may beplaced in representative areas of the forging for calibration andexamination purposes when removed by subsequent m
24、achin-ing. When holes or notches are not removed by subsequentmachining, the purchaser must approve the location of holes ornotches.5. Personnel Requirements5.1 Personnel performing the ultrasonic examinations to thispractice shall be qualified and certified in accordance with awritten procedure con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA745A745M19942009STANDARDPRACTICEFORULTRASONICEXAMINATIONOFAUSTENITICSTEELFORGINGS 奥氏体 锻件 超声波 检验

链接地址:http://www.mydoc123.com/p-459376.html