ASTM E2805-2018 Standard Practice for Measurement of the Biological Activity of Ricin.pdf
《ASTM E2805-2018 Standard Practice for Measurement of the Biological Activity of Ricin.pdf》由会员分享,可在线阅读,更多相关《ASTM E2805-2018 Standard Practice for Measurement of the Biological Activity of Ricin.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2805 11E2805 18Standard Practice forMeasurement of the Biological Activity of Ricin1This standard is issued under the fixed designation E2805; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONRicin is a member of the protein toxins that cause their physiological effect by inactivation ofribosomes. Ricin is a member of the
3、class 2 ribosome inactivating proteins (1).2 Other members of thisclass of toxins include the proteins abrin and Shiga toxin.Ricin Ricinus communis (Ricin) consists of two chains, the A-chain that is responsible for theN-glycosidase enzymatic activity and the B-chain that is needed for cell binding
4、and intra-cellularprocessing. Ricin is a heterogeneous protein with molecular weights ranging from approximately 62to 64 kilodaltons (kDa) (2). Both chains are glycosylated and of similar size (approximately 32 kDa).There are several genes encoding putative ricin and ricin-like proteins in the genom
5、e of R. communis(3) resulting in differences in the amino acid sequence of the subunits. The differences in amino acidsequence and glycosylation both contribute to the heterogeneity of ricin. Various research reports existdescribing different means of detecting ricin activity.1. Scope1.1 This guide
6、is intended for the manufacturers and users of ricin reference material. Ricin reference materials arewell-characterized materials that can be used to test detection devices and calibrate laboratory measurements. It is anticipated thatricin reference materials will be characterized by biochemical me
7、thods in addition to the measurement of biological activity.1.2 This practice details the measurement of ricin biological activity using a cell-free translation (CFT) assay (4).1.3 The CFT assay has been developed for use in any biotechnology laboratory where determination or confirmation of ricinbi
8、ological activity is required.1.4 The CFT assay has been validated by the U.S. Army Medical Research Institute of Infectious Diseases (USAMRIID)VP-016 Validation of Cell-Free Translation Assay for the Detection of Ricin Toxin Biological Activities in compliance (5) withGood Laboratory Practices (GLP
9、) Regulations of the Food and Drug Administration (21 CFR Part 58). Strict adherence to theprotocol is necessary for validity of the test results.1.5 Appendix X1 and Appendix X2 also provide guidance for the measurement of the biological activity of ricin usingcell-based assays and the use of synthe
10、tic enzyme substrates.1.6 Ricin is a category 2 select agent and acquisition of the ricin standard must adhere to the Center for Disease Control andPrevention (CDC) regulations. Ricin is listed on the select agent list (42 CFR Part 72).3 The possession, transfer, and use of ricinare restricted under
11、 the Public Health Security Preparedness Act (CRS Report RL31263 Public Health Security and BioterrorismPreparedness and Response Act (P.L. 107-188): Provision and Changes to Preexisting law). Access to stores of ricin is limited(USA Patriot Act, P.L. 107-56). Ricin is also a prohibited substance un
12、der the Biological Weapons Convention and the ChemicalWeapons Convention (CRS Report RL31559 Proliferation Control Regimes: Background and Status).1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1 This practice is under th
13、e jurisdiction ofASTM Committee E54 on Homeland SecurityApplications and is the direct responsibility of Subcommittee E54.01 on CBRNESensors and Detectors.Current edition approved Jan. 1, 2011Dec. 1, 2018. Published March 2011December 2018. Originally approved in 2011. Last previous edition approved
14、 in 2011 asE2805 11. DOI: 10.1520/E2805-11.10.1520/E2805-18.2 The boldface numbers in parenthesis refer to the list of references at the end of this standard.3 Available at http:/www.bt.cdc.gov/Agent/agentlist.asp.https:/emergency.cdc.gov/agent/agentlist.asp.This document is not an ASTM standard and
15、 is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only t
16、he current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.8 This standard does not purport to address all of the safety concerns, if any, associa
17、ted with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use. Ricin is an extremely dangerous toxin. See Section 9 for specific hazardsinf
18、ormation.1.9 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barri
19、ers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:4E2458 Practices for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being BiologicalAgents and Toxins from Nonporous SurfacesE3131 Specification for Nucleic Acid-Based Systems for Bacterial Path
20、ogen Screening of Suspicious Visible PowdersF2149 Test Method for Automated Analyses of Cellsthe Electrical Sensing Zone Method of Enumerating and Sizing SingleCell Suspensions2.2 Code of Federal Regulations:21 CFR Part 58 Good laboratory practice for nonclinical laboratory studies542 CFR Part 72 In
21、terstate shipment of etiologic agents62.3 ANSI/ATCC Standard:7ASN-0001-2009 Standardization of In-Vitro Assays to Determine Anthrax Toxin Activities2.4 ISO Standard:8ISO Guide 34 General requirements for the competence of reference material producersISO 203911 Biotechnology Cell Counting Part 1: Gen
22、eral Guidance on Cell Counting Methods2.5 Federal Standard:618 USC 178 Definitions3. Terminology3.1 Definitions:3.1.1 aseptic technique, noperation or performance of a procedure or method under carefully controlled conditions to reducethe risk of exposure and prevent the introduction of unwanted mat
23、erial/matter (contamination) into a sample. E24583.1.2 calibration, nset of operations that establish, under specified conditions, the relationship between the values ofquantities indicated by a measurement instrument or measuring system or values represented by a material measure or a referencemate
24、rial and the corresponding values realized by standards. Eurochem Selection (6)3.1.3 hazard, nsomething that is potentially dangerous or harmful, often the root cause of an unwanted outcome; a danger orperil. NIMS3.1.4 inhibition, nundesirable effect that can result in a false negative result and is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME28052018STANDARDPRACTICEFORMEASUREMENTOFTHEBIOLOGICALACTIVITYOFRICINPDF

链接地址:http://www.mydoc123.com/p-1243873.html