ASTM D4073 D4073M-2006(2019)e1 Standard Test Method for Tensile-Tear Strength of Bituminous Roofing Membranes.pdf
《ASTM D4073 D4073M-2006(2019)e1 Standard Test Method for Tensile-Tear Strength of Bituminous Roofing Membranes.pdf》由会员分享,可在线阅读,更多相关《ASTM D4073 D4073M-2006(2019)e1 Standard Test Method for Tensile-Tear Strength of Bituminous Roofing Membranes.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4073/D4073M 06 (Reapproved 2019)1Standard Test Method forTensile-Tear Strength of Bituminous Roofing Membranes1This standard is issued under the fixed designation D4073/D4073M; the number immediately following the designation indicates theyear of original adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially revised in January 2019.1. Scope1.1 This test method covers the determi
3、nation of the tensile-tear strength of bituminous roofing membranes.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system are not necessarily exact equivalents; therefore, toensure conformance with the standard, each sy
4、stem shall beused independently of the other, and values from the twosystems shall not be combined.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health,
5、and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of Internationa
6、l Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D95 Test Method for Water in Petroleum Products andBituminous Materials by DistillationD2829/D2829M Practice for Sampling and Analysis
7、 of Ex-isting Built-Up Roof SystemsD3617/D3617M Practice for Sampling and Analysis ofBuilt-Up Roof Systems During Application3. Summary of Test Method3.1 The tensile-tear strength of a membrane in both longi-tudinal and transverse directions is determined by measuringthe maximum load when notched sp
8、ecimens of specific dimen-sions are tested to failure at an arbitrary, fixed, tensile strainrate.4. Significance and Use4.1 Determining the tensile-tear strength of laboratory andfield samples of roofing membranes should be useful indeveloping performance criteria, and as one basis for compari-son o
9、f different materials and systems. The effects oftemperature, moisture, and aging may be evaluated by appro-priate selection of field samples or conditioning of laboratorysamples, and tests may be conducted in an environmentalchamber.5. Apparatus5.1 Testing MachineUniversal or standard testing machi
10、newith automatic load and strain recording equipment, capable ofcross-head movement at a constant rate of 2.54 mm/min 0.100in./min.5.2 GripsSelf-aligning grips or clamps for holding the testspecimen between the stationary member and the movablemember or cross-head of the testing machine. Jaw faces o
11、f thegrips shall be 75 mm 3.0 in. wide by 50 mm 2.0 in. deep,shall provide uniform clamping pressure, and shall preventslippage of the specimen during test.5.3 Environmental ChamberAn insulated chamber withheating and cooling capabilities, designed to enclose the testspecimen and clamps so that the
12、temperature may be controlledduring a test.6. Sampling6.1 Field SamplesField samples shall be taken in accor-dance with Practice D2829/D2829M or D3617/D3617M but ofa size suitable to provide sufficient material for testing in boththe machine and cross-machine directions. In cases where fieldapplied
13、aggregate is in place, it shall be removed with a hotscraper such as a putty knife without damaging the top felt. Incases where the insulation facer is a part of the membranesystem it should be included and so reported.6.2 Laboratory Samples:1This test method is under the jurisdiction of ASTM Commit
14、tee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.20 onRoofing Membrane Systems.Current edition approved Jan. 1, 2019. Published January 2019. Originallyapproved in 1981. Last previous edition approved in 2013 as D4073 06 (2013).DOI: 10.1520/D4073_D4073M-06R19E
15、01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
16、x C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD4073D4073M20062019E1STANDARDTESTMETHODFORTENSILETEARSTRENGTHOFBITUMINOUSROOFINGMEMBRANESPDF

链接地址:http://www.mydoc123.com/p-1243607.html