SSPC QP 9-2008 Standard for Evaluating Qualifications of Painting Contractors Who Apply Architectural Paints and Coatings《使用建筑漆料和涂料的涂料承包商资格评估标准》.pdf
《SSPC QP 9-2008 Standard for Evaluating Qualifications of Painting Contractors Who Apply Architectural Paints and Coatings《使用建筑漆料和涂料的涂料承包商资格评估标准》.pdf》由会员分享,可在线阅读,更多相关《SSPC QP 9-2008 Standard for Evaluating Qualifications of Painting Contractors Who Apply Architectural Paints and Coatings《使用建筑漆料和涂料的涂料承包商资格评估标准》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、SSPC-QP 9August 1, 20081SSPC: The Society for Protective CoatingsQualifiCaTion ProCedure no. 9Standard for Evaluating Qualifications of Painting Contractors Who apply architectural Paints and Coatings1. Scope1.1 This standard procedure contains requirements for evaluating the qualifications of paint
2、ing contractors who apply architectural coatings on commercial or institutional structures, and defines a minimum standard for qualification.1.2 The objective of this procedure is to determine if a painting contractor has the management structure; organiza-tion structure; qualified personnel; techni
3、cal capability; quality management system; and safety and environmental compli-ance programs in order to perform surface preparation and architectural coating application of the required quality under the conditions and restrictions specified by the owner. 1.3 In addition to the evaluation criteria
4、outlined in this procedure, the owner is advised to review items not covered by this procedure. Examples include, but are not limited to, the applicants financial stability; performance history; bonding capacity; and ability to successfully complete a specific project in the time frame required.1.4
5、The procedure encompasses the application of archi-tectural coatings in the commercial and institutional sectors only. Field industrial or marine protective coating applications on steel structures is covered by the requirements of SSPC-QP 1, “Standard Procedure for Evaluating Qualifications of Pain
6、ting Contractors.” Painting of steel and miscellaneous metal parts in the shop is covered by SSPC-QP 3, “Standard Procedures for Evaluating the Qualifications of Shop Painting Applicators.” The residential painting and decorating finishing markets are covered by the Painting and Decorating Contracto
7、rs of America (PDCA) Accreditation Program1.2. description2.1 definiTionSContractor: The individual or entity with which the owner or customer has entered into an agreement to provide surface preparation and architectural paint and coating application services. 1 For information on PDCA accreditatio
8、n, contact the Painting and Decorating Contractors of America, 1801 Park 270 Drive, Suite 220, St. Louis, MO 63146,or visit http:/www.pdca.org. architectural Coatings: Paints and coatings applied on-site to new and existing commercial, institutional and industrial buildings. auditor: The person tech
9、nically qualified to perform audits of a contractors management structure; organization structure; personnel, technical capability; quality management system; and safety, health and environmental compliance programs on behalf of the Qualifying Agency and report findings to the Qualifying Agencys aud
10、it program manager. owner: The owner (or owners legal representative) of the building/structure/facility to be painted.Customer: Entity (e.g., the building owner, developer, property manager or leasing agent, general contractor, or architect/designer) having the agreement with the painting contracto
11、r for architectural coating application.Procedure: The sequence of steps taken to carry out a particular course of action.Qualification: The objective evidence by which written assurance is given that an applicant conforms to the prescribed set of conditions or requirements of this procedure. Qualif
12、ying agency: The organization responsible for development, maintenance, sponsorship, and operation of a program to ensure uniform compliance with the provisions of this procedure.2.2 TYPeS of STruCTureS: Commercial and institu-tional structures encompass a wide range of building types and interior a
13、nd exterior configurations. Architectural coatings are normally applied for aesthetic purposes, protection, or signage. Examples include but are not limited to: retail stores, shopping centers; office buildings; schools, colleges and universities; libraries, institutional buildings, public and milit
14、ary housing; apartment buildings; warehouses and product storage and distribution centers, medical and dental facilities; sports and recreational facilities; airports, rail and bus stations. Although the required evaluation functions are similar for all commercial and institutional structures, the s
15、pecific skills (e.g., scaffolding; hazardous paint removal) are often quite different for painting a particular office building and painting a particular military or public housing project.2.3 funCTionS To Be eValuaTed: There are four qualification categories to be evaluated: Management Procedures,
16、Technical Capabilities, Job Quality Procedures, and Safety, Health and Environmental Compliance. General SSPC-QP 9August 1, 20082requirements for each of these categories are presented in Section 3.2.4 eValuaTion CriTeria: The Qualifying Agency shall develop criteria or rating plans to initially eva
17、luate and monitor each applicant against the established criteria. The Qualifying Agency shall also determine which of the specific evaluation items within the four categories are to be reviewed during follow-up audits, ensuring the items evaluated are the same for all applicants. 2.5 QualifiCaTion
18、CaTeGorieS: This standard is composed of four qualification categories described below. Where no Category is specified in a contracting document, requirements for Category 1 shall apply. Contractors who are qualified to Categories 4, 3 or 2 are expected to progress to the next highest qualification
19、category within a time frame established by the qualifying agency.Category 1: Contractor has demonstrated a minimum of five years of successful experience applying architectural paints and coatings in the commercial or institutional property markets and is found to be in compliance with all requirem
20、ents of this procedure. Category 1 qualification requires both an office and a jobsite audit.Category 2: Contractor has demonstrated a minimum of three years of successful experience applying architectural paints and coatings, in the commercial or institutional property markets and is found to be in
21、 compliance with all requirements of this procedure with the exception of full implementation of a Job Quality Monitoring System in the field. Category 2 qualification requires an office audit only. Category 3: Contractor has a minimum of two years of successful experience applying architectural pai
22、nts and coatings in the commercial or institutional property markets and is found to be in compliance with all requirements of this procedure with the exception of development and implementa-tion of a Job Quality Monitoring System and an Environmental Compliance Program in accordance with requiremen
23、ts of Sections 3.3.3 and 3.4.2. No site audit is required to qualify for this Category.Category 4: Contractor has minimal experience (0-2 years) but has established programs to comply with the Management requirements of this procedure as a result of a review and acceptance of submittals by the Quali
24、fying Agency. No site audit is required for this Category.A comparison of the requirements for each of the catego-ries is shown in Table 1.To qualify for any category in the leftmost column, the contractor shall meet all of the requirements listed in the corresponding row. For example, to qualify fo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SSPCQP92008STANDARDFOREVALUATINGQUALIFICATIONSOFPAINTINGCONTRACTORSWHOAPPLYARCHITECTURALPAINTSANDCOATINGS

链接地址:http://www.mydoc123.com/p-1054507.html