SSPC PAINT 40-2007 Zinc-Rich Moisture-Cure Polyurethane Primer Performance-Based《基于性能的富锌水固聚氨酯底漆》.pdf
《SSPC PAINT 40-2007 Zinc-Rich Moisture-Cure Polyurethane Primer Performance-Based《基于性能的富锌水固聚氨酯底漆》.pdf》由会员分享,可在线阅读,更多相关《SSPC PAINT 40-2007 Zinc-Rich Moisture-Cure Polyurethane Primer Performance-Based《基于性能的富锌水固聚氨酯底漆》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、SSPC-Paint 40April 1, 20071SSPC: The Society for Protective CoatingsPainT SPECiFiCaTiOn nO. 40Zinc-Rich Moisture-Cure Polyurethane Primer, Performance-Based1. Scope1.1 This specification contains performance requirements for an organic zinc-rich moisture-cure polyurethane primer with a thermoset bin
2、der. SSPC PS 12.00 describes this primer as a Type II B zinc-rich primer. 2. Description2.1 This zinc-rich moisture-cure polyurethane primer is characterized by the presence of free polyisocyanate groups capable of reacting with atmospheric moisture in order to form a film. Either single or two-comp
3、onent packaging is acceptable. Zinc loading requirements are given in Section 4.2.1. Appendix A provides additional information for slip critical applications. 2.2 This primer is available in two Types. Type I formula-tions, applied over properly prepared carbon steel surfaces, are suitable for use
4、on parts or structures exposed in Environ-mental Zones 1Ainterior, normally dry; IBexterior, normally dry; 2Afrequently wet by fresh water, excluding immersion, 2Bfrequently wet by salt water, excluding immersion, and 3Bchemical exposure, neutral (with suitable topcoat). Type II formulations, applie
5、d over properly prepared carbon steel surfaces, are suitable for exposure in Environmental Zone 2Cfresh water immersion. Type II primers meet the require-ments of Section 7.4 for fresh water immersion in addition to the requirements for Type I. 2.3 Primers described by this standard provide corrosio
6、n resistance and accept application of suitable topcoats. Unless a Type I primer is specified, the primer described by this standard is intended to comply with Type II requirements.2.4 This primer is intended for application by spray directly to a steel substrate, with the allowance for small area t
7、ouch-up by brush (see Note 11.1).3. Reference Standards 3.1 The latest issue, revision, or amendment of the refer-ence documents in effect on the date of invitation to bid shall govern unless otherwise specified. Those documents marked with an asterisk (*) are referenced only in the Notes or the App
8、endix, which are not requirements of this specification.3.2. If there is a conflict between the requirements of any of the cited reference documents and this standard, the requirements of this standard shall prevail.3.3 SSPC STanDaRDS anD JOinT STanDaRDS: Guide 13 Guide for the Identification and Us
9、e of Industrial Coating Materials in Computerized Product Data-basesSP 1 Solvent CleaningSP 5/naCE no. 1 White Metal Blast CleaningPa 2 Measurement of Dry Coating Thick-ness with Magnetic GagesPS 12.00 Guide to Zinc-Rich Coating Sys-tems3.4 aSTM inTERnaTiOnaL STanDaRDS:1a 572 Standard Specification
10、for High-Strength Low-Alloy Columbium-Vanadium Structural Steel D 185 Standard Test Methods for Coarse Particles in Pigments, Pastes, and PaintsD 520 Standard Specification for Zinc Dust Pigment* D 562 Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer
11、-Type ViscometerD 714 Standard Test Method for Evaluating Degree of Blistering of Paints* D 1475 Standard Test Method for Density of Liquid Coatings, Inks, and Related Products* D 1640 Standard Test Methods for Drying, Curing, or Film Formation of Organic Coatings at Room TemperatureD 1654 Standard
12、Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments1 ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. Standards are available online at http:/www.astm.org.SSPC-Paint 40April 1, 20072* D 2369 Standard Test Method for Volatile Conte
13、nt of Coatings* D 2371 Standard Test Method for Pigment Content of Solvent-Reducible PaintsD 2794 Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)D 3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup ApparatusD 4417 Stan
14、dard Test Methods for Field Measurement of Surface Profile of Blast Cleaned SteelD 4541 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion TestersD 5894 Standard Practice for Cyclic Salt Fog/UV Exposure of Painted Metal, (Alternating Exposures in a Fog/Dry Cabinet and a U
15、V/Condensation Cabinet)D 6580 Standard Test Method for the Determination of Metallic Zinc Content in Both Zinc Dust Pigment and in Cured Films of Zinc-Rich Coatings3.5 FEDERaL SPECiFiCaTiOnS anD STanDaRDS:2FED-STD 141 Paint, Varnish, Lacquer and Related Materials: Methods of Sampling, Inspection, an
16、d Testing * Method 3011 Condition in ContainerMethod 4331 Spraying Properties3.6 aMERiCan naTiOnaL STanDaRDS inSTiTUTE (anSi) STanDaRD:3anSi Z129.1 Hazardous Industrial ChemicalsPrecautionary Labeling3.7 american association of Highway and Transporta-tion Officials (AASHTO) Specification4* Standard
17、Specifications for Highway Bridges, Division 1, Section 10.32.3.2.3, Appendix A, Testing Method to Determine the Slip Coefficient for Coatings Used in Bolted Joints4. Composition Requirements4.1 The manufacturer is given wide latitude in the selection of materials and manufacturing processes. 4.2 Pi
18、GMEnT REQUiREMEnT4.2.1 The major pigment component in this coating is zinc dust. The paint shall contain a minimum of 65% zinc dust pigment by weight in the dry film per ASTM D 6580 (see Notes 11.2 and 11.3). 4.2.2 Other optional pigment components include extenders, curing aids, tinting colors, and
19、 suspension and pot life control agents. 4.3 RESin REQUiREMEnT: The resin used in the coating shall be a polyisocyanate-based product that cures through a chemical reaction with atmospheric moisture. Use of other resins or modifiers shall be minimal and limited to products necessary for formula ingr
20、edient compatibility and to improve recoating properties. See Note 11.4 for information on modi-fying resins and Note 11.5 for information on volatile organic compound (VOC) content.5. Standard Testing Conditions5.1 TEST PanELS: The hot rolled steel test panels shall conform to ASTM A 572. Panel siz
21、e shall be 100 mm x 150 mm x 3.2 mm (4 inch x 6 inch x 1/8 inch). Test panels shall be solvent cleaned in accordance with SSPC-SP 1 prior to blast cleaning. The test panels shall be blast cleaned in accordance with SSPC-SP 5. The blast profile shall be 44 to 57 micrometers (1.75 to 2.25 mils) as mea
22、sured in accordance with ASTM D 4417, Method C. 5.2 aPPLiCaTiOn: The primer shall be spray applied as a single coat in accordance with manufacturers written recommendations. The primer shall show no streaking, running, sagging, or other defects during application or while drying.5.3 DRY FiLM THiCKnE
23、SS: The dry film thickness (DFT) on the test panels shall meet the manufacturers written recom-mended range. The DFT shall be measured in accordance with SSPC-PA 2, Appendix 5. 5.4 CURE: The primer shall be dried and cured in accor-dance with manufacturers written recommendations. Before any testing
24、, all coated panels shall be aged for a minimum of 7 days in an environment with a minimum relative humidity of 55%, and at a temperature of 23 2 C (73.5 3.5 F).5.5 SCRiBinG: Scribe two parallel lines on the face of the coated panels so as to expose the underlying metal 2 FED STD 141 is available fr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SSPCPAINT402007ZINCRICHMOISTURECUREPOLYURETHANEPRIMERPERFORMANCEBASED 基于 性能 富锌水固 聚氨酯 底漆 PDF

链接地址:http://www.mydoc123.com/p-1054476.html