SAE J 2843-2013 R-1234yf [HFO-1234yf] Recovery Recycling Recharging Equipment for Flammable Refrigerants for Mobile Air-Conditioning Systems《移动空调系统易燃制冷剂的R-1234fy (HFO-1234yf)复原 回收 .pdf
《SAE J 2843-2013 R-1234yf [HFO-1234yf] Recovery Recycling Recharging Equipment for Flammable Refrigerants for Mobile Air-Conditioning Systems《移动空调系统易燃制冷剂的R-1234fy (HFO-1234yf)复原 回收 .pdf》由会员分享,可在线阅读,更多相关《SAE J 2843-2013 R-1234yf [HFO-1234yf] Recovery Recycling Recharging Equipment for Flammable Refrigerants for Mobile Air-Conditioning Systems《移动空调系统易燃制冷剂的R-1234fy (HFO-1234yf)复原 回收 .pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2843_201301 AEROSPACE SURFACE VEHICLE STANDARD J2843 JAN2013 Issued 2011-02 Revi
5、sed 2013-01 Superseding J2843 FEB2012 R-1234yf HFO-1234yf Recovery/Recycling/Recharging Equipment for Flammable Refrigerants for Mobile Air-Conditioning Systems RATIONALE This SAE Standard is revised such that the pressurized leak check is conducted with the HVAC blower on “Low“ and the SAE J2913 co
6、mpliant leak detector set to high sensitivity (4 grams per year leak rate). 1. SCOPE This SAE Standard applies to equipment to be used with R-1234yf refrigerant only. It establishes requirements for equipment used to recharge R-1234yf to an accuracy level that meets Section 9 of this document and pu
7、rity levels defined in SAE J2099. Refrigerant service equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Equipment shall be certified to meet all performance requirements outlined in this document
8、and international/regional construction and safety requirements as outlined in this document. 1.1 Purpose The purpose of this SAE Standard is to establish the specific minimum equipment requirements for the recovery/recycle/recharge of HFO-1234yf (R-1234yf) refrigerant that has been directly removed
9、 from, and is intended for reuse in, mobile air conditioning systems and system recharging of recycled or virgin R-1234yf. Establishing such specifications will ensure that system operation with recycled R-1234yf will provide the same level of performance and durability as new refrigerant. NOTE: R-1
10、234yf is mildly flammable refrigerants called mildly flammable have a maximum burning velocity of 0.10 m/s when tested at 23 C and 101.3 kPa (ASHRAE 34 and ISO 817 Class 2L). SAE J2843 Revised JAN2013 Page 2 of 21 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this
11、specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside U
12、SA), www.sae.org. 2.1.1.1 System Design Guidelines SAE J639 Safety Standards for Motor Vehicle Refrigerant Vapor Compressions Systems SAE J2844 R-1234yf (HFO-1234yf) New Refrigerant Purity and Container Requirements for Use in Mobile Air-Conditioning Systems 2.1.1.2 Service Activities SAE J2888 R-12
13、34yf Service Hose, Fittings and Couplers for Mobile Refrigerant Systems Service Equipment 2.1.1.3 Technician Service Procedures SAE J2845 R-1234yf HFO-1234yf and R-744 Technician Training for Service and Containment of Refrigerants Used in Mobile A/C Systems 2.1.1.4 Service Equipment SAE J2099 Stand
14、ard of Purity for Recycled HFC-134a (R-134a) and HFO-1234yf (R-1234yf) for Use in Mobile Air-Conditioning Systems SAE J2296 Retest of Refrigerant Cylinder SAE J2912 Performance Requirements for R-134a and R-1234yf Refrigerant Diagnostic Identifiers (RDI) for Use with Mobile Air Conditioning Systems
15、SAE J2913 R-1234yf HFO-1234yf Refrigerant Electronic Leak Detectors, Minimum Performance Criteria SAE J2927 R-1234yf Refrigerant Identifier Installed in Recovery and Recycling Equipment for Use with Mobile A/C Systems 2.1.1.5 Reference Documents SAE J1739 Potential Failure Mode and Effects Analysis
16、in Design (Design FMEA), Potential Failure Mode and Effects Analysis in Manufacturing and Assembly Processes (Process FMEA) SAE J2911 Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards S
17、AE J2843 Revised JAN2013 Page 3 of 21 2.1.2 CGA Publications Available from CGA, Crystal Square #2, Jefferson Davis Highway, Arlington, VA 22202-4102. CGA Pamphlet S-1.1 Pressure Relief Device Standard Part 1 - Cylinders for Compressed Gases 2.1.3 DOT Publications Available from the Superintendent o
18、f Documents, U.S. Government Printing Office, Washington, DC 20402. DOT Standard, CFR Title 49, Section 173.304 Shippers - General Requirements for Shipments and Packaging 2.1.4 UL Publications UL is currently in the process of updating UL 1963 to comprehend the use with A2L fluids. All references t
19、o UL 1963 within this document shall be to UL1963 (version 4). The following are exceptions to UL1963: 1. A hazardous location plug shall not be required. 2. A hose assembly inside the machine shall not exceed 0.91 meters (3 feet) in length. 3. The hose tensile pull requirement shall be 113 Kg (250
20、lbs) minimum. 4. The required hose permeation shall be 4.9 Kg/m2 (1 Lb/Ft2) /yr. maximum. Available from Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096, Tel: 847-272-8800, . UL 1769 Cylinder Valves UL 1963 version 4 Refrigerant Recovery/charge Equipment 2.1.5 Other Pub
21、lications ANSI/ISA 12.12.01 (Current Revision) Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous (Classified) Locations (these standards reference NFPA-70 and NFPA497) 3. SPECIFICATION AND GENERAL DESCRIPTION 3.1 The equipment shall be
22、able to remove, recover, recycle and recharge R-1234yf refrigerant on-site from MAC systems per the test procedures in Sections 8, 9, and 10. 3.2 The equipment shall be suitable for use in an automotive service garage environment and be capable of continuous operation in ambient temperatures from 10
23、 to 50 C (50 to 120 F) and meet the accuracy defined in this standard. 3.3 The equipment shall be certified that it meets requirements of this document and the requirements of SAE J2911. 3.3.1 The manufacturer can state certification of compliance with this Standard only after meeting the requiremen
24、ts in SAE J2911. (See Appendix B for additional information.) 3.3.2 Any independent testing organization that has received approval by the Administrator to certify equipment as meeting the standard requirements identified under US EPA 40 CFR Ch. I (7-1-08 Edition) 82.38 shall provide certification o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ28432013R1234YFHFO1234YFRECOVERYRECYCLINGRECHARGINGEQUIPMENTFORFLAMMABLEREFRIGERANTSFORMOBILEAIRCONDITIONINGSYSTEMS

链接地址:http://www.mydoc123.com/p-1027635.html