DLA MIL-PRF-1 1071 D-2009 ELECTRON TUBE GAS SWITCHING TYPE 6962.pdf
《DLA MIL-PRF-1 1071 D-2009 ELECTRON TUBE GAS SWITCHING TYPE 6962.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 1071 D-2009 ELECTRON TUBE GAS SWITCHING TYPE 6962.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-1/1071D 14 July 2009 _ SUPERSEDING MIL-PRF-1/1071C(CR) 25 June 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, GAS SWITCHING TYPE 6962 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube de
2、scribed herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: ATR, L-band, Fo = 1,285 MHz. ABSOLUTE RATINGS: Parameter: Unit: Incident power Mw Du - Alt ft Maximum: Minimum: 2 - 0.001 - 10,000 - PHYSICAL CHARACTERISTICS: Dimensions: See figures 1 and 2. Mounting: See
3、figure 1 and 1/. Weight: 6 pounds (approximate). TEST CONDITIONS: Parameter: Unit: Incident power kw tp s Du - VSWR F MHz Test condition 1: Maximum Minimum 525 475 4.4 3.6 0.001 - 1.05 - 1,298 1,272 Test condition 2: Maximum Minimum 2,100 1,900 4.4 3.6 0.001 - - - 1,298 1,272 See footnotes at end of
4、 table I. GENERAL: Preproduction sample approval: Required. 2/ AMSC N/A FSC 5960 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1071D 2 TABLE I. Testing and inspection. Limits Inspection Method MIL-STD-1311 Notes Test Conditions
5、 Symbol Min Max Unit First article inspection (Preproduction) Loaded Q 4461 2/ 3/ - - QL - 2.5 - High-level VSWR 4474 3/ 1 VSWR - 1.15 - Degradation due to vibration 4021 - - - - - - Conformance inspection, part 1 Tuning susceptance 4482 4/ 3/ - - Method A b -0.03 +0.03 - Firing time 4486 3/ 1 t - 5
6、 sec Arc loss 4488 3/ 1 La - 0.3 dB Temperature cycling 1027 - - 1 cycle - - - - Temperature cycling life test 1027 - - Group D; 10 cycles (min) - - - - Conformance inspection, part 2 Dielectric material strain 4101 - - - - - - Normalized conductance 4484 3/ - g - 0.03 - Variable-frequency vibration
7、 1031 - - F = 50 to 500 Hz; 15 G; t = 30 minutes (min) - - - - Insertion - 5/ - - - - - Conformance inspection, part 3 Life test - 6/ 2 Group D t 1,000 - hours Life-test end points: Tuning susceptance Normalized conductance Arc loss - 4482 4484 4488 - 3/ 3/ 3/ - - - 1 Method A b g La -0.05 - - +0.05
8、 0.05 0.4 - - dB See footnotes at top of next page. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1071D 3 TABLE I. Testing and inspection - Continued. 1/ Suitable rf gaskets will be supplied with each tube. 2/ The number of first article
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11071D2009ELECTRONTUBEGASSWITCHINGTYPE6962PDF

链接地址:http://www.mydoc123.com/p-691920.html