ASTM D3768-2006 Standard Test Method for Microcellular Urethanes-Flexural Recovery《微孔氨基甲酸乙酯挠曲恢复性的标准试验方法》.pdf
《ASTM D3768-2006 Standard Test Method for Microcellular Urethanes-Flexural Recovery《微孔氨基甲酸乙酯挠曲恢复性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3768-2006 Standard Test Method for Microcellular Urethanes-Flexural Recovery《微孔氨基甲酸乙酯挠曲恢复性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3768 06Standard Test Method forMicrocellular UrethanesFlexural Recovery1This standard is issued under the fixed designation D 3768; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the procedure and apparatus formeasuring the flexural recovery of microcellular urethanes.1.2 The values stated in S
3、I units are to be regarded asstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory li
4、mitations prior to use.NOTE 1There is no known ISO equivalent to this test method.2. Referenced Documents2.1 ASTM Standards:2D 3040 Practice for Preparing Precision Statements forStandards Related to Rubber and Rubber Testing3E 691 Practice for Conducting an Interlaboratory Study toDetermine the Pre
5、cision of a Test Method3. Significance and Use3.1 This test method is used to indicate the ability of amaterial to recover after a 180 bend around a 12.7-mm0.5-in. diameter mandrel at room temperature.3.2 Before proceeding with this test method, referenceshould be made to the specification of the ma
6、terial being tested.Any test specimen preparation, conditioning, or dimensions, orcombination thereof, and testing parameters covered in thematerials specification shall take precedence over those men-tioned in these test methods. If there are no material specifi-cations, then the default conditions
7、 apply.NOTE 2This test method is applicable to solid urethanes.4. Apparatus4.1 Flexural Recovery Test FixtureThe test fixture shallconsist of a 12.7-mm diameter mandrel mounted to a baseequipped with a protractor. A drawing of a typical test fixtureis shown in Fig. 1.4.2 Timer, capable of indicating
8、 seconds.4.3 Thickness Indicator, accurate to 0.03 mm.5. Test Specimens5.1 The test specimens shall be cut from molded plaques orparts. The recommended standard test specimen is 4 mm in1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Sub
9、committee D20.22 on Cellular MaterialsPlastics and Elastomers.Current edition approved March 15, 2006. Published April 2006. Originallyapproved in 1979. Last previous edition approved in 2000 as D 3768 - 96 (2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM C
10、ustomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.FIG. 1 Example Fixture for Flexural Recovery Test1*A Summary of Changes section appears at the end of this standard.Copyright ASTM Inter
11、national, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.thickness, and the minimum specimen thickness shall not beless than 3 mm. The specimen shall be 25 mm in width by 150mm in length 1 by 6 in.6. Conditioning6.1 Unless otherwise specified, condition the speci
12、mens andfixtures a minimum of1hat236 2C and 50 6 5 % relativehumidity before testing.7. Procedure7.1 There shall be at least three recovery measurements.7.2 Measure the thickness of specimen to the nearest 0.03mm.7.3 Insert the test specimen in the lower slot of the specimenclamp and position the en
13、d of the specimen flush with the rearface of the bend mandrel. Tighten the clamp while holding thespecimen in a horizontal position. (Do not allow the outer endof the specimen to be in contact with the base of the testfixture.) A spacer of approximately the same thickness as thetest specimen must be
14、 used in the upper slot to ensure properclamping in the lower slot. A specimen mounted in a testfixture at the start of a test is shown in Fig. 2.7.4 Make an initial reading where the mandrel edge of thespecimen (the surface of the test specimen that is in contactwith the bend mandrel) intercepts th
15、e protractor scale. Make areading to the nearest 1 and record the value.7.5 Apply force approximately 30 mm 1.25 in. from theclamp and bend the specimen 180 around the mandrel. Holdthe specimen for 5 6 1 s in the bent position, then releaseslowly and allow to recover. Start the timer immediately upo
16、nrelease. Do not allow the specimen to drag on the fixture baseduring recovery.Aspecimen that is being bent 180 around themandrel is shown in Fig. 3.7.6 Read the intercept of the mandrel edge of the specimenon the protractor scale after 30-s and 300-s recovery. Thedifference between these readings a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD37682006STANDARDTESTMETHODFORMICROCELLULARURETHANESFLEXURALRECOVERY 微孔 氨基 甲酸 挠曲 恢复 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515450.html