DLA A-A-55436-1994 AIR CONDITIONERS DOUBLE HUNG WINDOW MOUNT《双吊钩窗装空调》.pdf
《DLA A-A-55436-1994 AIR CONDITIONERS DOUBLE HUNG WINDOW MOUNT《双吊钩窗装空调》.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-55436-1994 AIR CONDITIONERS DOUBLE HUNG WINDOW MOUNT《双吊钩窗装空调》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、I INCH-POUND I A-A- 5543 6 May 31, 1994 COMMERCIAL ITEM DESCRIPTION AIR CONDITIONERS, DOUBLE HUNG WINDOW MOUNT The General Services Administration has authorized the use of this commercial item description in preference to Federal Specification 00-A-372 for Type I, Style I. ABSTRACT This commercial
2、item description (CID) covers the requirements for window mount air conditioning units. The units described herein shall be capable of delivering conditioned air to enclosed spaces. All air conditioning units offered shall include a source of refrigeration for cooling and dehumidification, and a sou
3、rce for circulating and cleaning the air. SALIENT CHARACTERISTICS Sizes, caDacities, electrical characteristics, and enerav efficiency ratios. The window mount air conditioners shall be of the following sizes, capacities, electrical characteristics and energy efficiency ratios (EERs) as specified in
4、 table I. Beneficial comments (recommendations, additions, deletions, clarifications, etc.,) and any data which may improve this document should be sent to: Defense General Supply Center (DGSC), ATTN: DGSC-SSA, 8000 Jefferson-Davis Highway, Richmond, VA 23297-5678. AMSC N/A FSC 4120 DISTRIBUTION STA
5、TEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5543b W 9999974 OLb4333 124 W A-A-55436 TABLE I. Sizes, Capacities, and Electrical Requirements. Size Cooling Electrical Amperes Coo
6、ling Capa city Rating Cooling EER (in BTU/Hr) (in volts) * (MIN) * 1 7,500- 8,999 115 7.5 8.5 2 9,000-11,999 115 12.0 8.8 3 12,000-14,999 230/208 6.0/6.3 8.8 4 15,000-17,499 230/208 9.1/9.3 8.8 5 17,500-Over 230/208 11.5/12.0 9.0 * The definition for EER shall be in accordance with AHAM * Plus or mi
7、nus 5 percent. Standard RAC-1. Unit desiqn. The air conditioners shall be designed for double hung windows. The design shall allow the chassis to be easily removed for servicing from the inside without breaking the weathertight seal on the mounting cabinet. The maximum dimensions shall be 19 inches
8、high by 26 inches wide. All mounting devices necessary for installation shall be provided. Operation. The air conditioning units shall operate on 60 Hz, single phase current and shall control the exhaust of room air and the admittance of outside air. An adjustable thermostat shall be provided to aut
9、omatically control the temperature from 65 to 85 degrees Fahrenheit (eF), 2 3eF. The circulating fan motor shall have three or more speeds. For electrical safety, the air conditioners shall be in accordance with Underwriters Laboratories (UL) Inc. Standard No. 484. Acceptable evidence that the air c
10、onditioners conform to UL Standard 484 shall be the UL label or listing mark. Cooling capacity ratings shall be in accordance with the Association of Home Appliance Manufacturers (AHAM) Standard RAC-1. Acceptable evidence of meeting these ratings is a listing in the latest edition of the AHAM Direct
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA554361994AIRCONDITIONERSDOUBLEHUNGWINDOWMOUNT 吊钩 空调 PDF

链接地址:http://www.mydoc123.com/p-686769.html