CEPT T TR 02-06 E-1986 Environmental Conditions for Telecommunications Equipment at Weather- Protected Locations (Excluding Telecommunication Centres with Temperature and Humidity .pdf
《CEPT T TR 02-06 E-1986 Environmental Conditions for Telecommunications Equipment at Weather- Protected Locations (Excluding Telecommunication Centres with Temperature and Humidity .pdf》由会员分享,可在线阅读,更多相关《CEPT T TR 02-06 E-1986 Environmental Conditions for Telecommunications Equipment at Weather- Protected Locations (Excluding Telecommunication Centres with Temperature and Humidity .pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、CEPT T/TR*OZ-Ob*E 2326434 OOL052Y b W 0 TTR02-06E Page 1 Recommendation T/TR 02-06 (Montpellier 1984, revised in Odense 1986) ENVIRONMENTAL CONDITIONS FOR TELECOMMUNICATION EQUIPMENT (EXCLUDING TELECOMMUNICATION CENTRES WITH TEMPERATURE AND HUMIDITY CONTROLS) AND IN THE OPEN AIR AT WEATHER-PROTECTED
2、 LOCATIONS Recommendation proposed by Working Group T/WG 12 “Transmission” (TR) Text of the Recommendation revised adopted by Commission “Telecommunication”: “The European Conference of Posts and Telecommunications Administrations, Considering - that some equipment used for telecommunication purpose
3、 is placed at weather-protected locations which are not - that in view of the installation of equipment made by different manufacturers, it is necessary to define the - that the relevant CCITT and CCIR Recommendations do not provide for the necessary standardization, - that the CCITT and CCIR do not
4、 plan to standardize the environmental conditions at weather-protected locations or in the open air, - that the Administrations support the harmonization of telecommunication equipment and systems which could lead to a reduction in the development and production costs for the manufacturers supplying
5、 equipment to different countries, that the Administrations prefer the use of natural convection cooling whenever possible, telecommunication centres with temperature and humidity controls and some in the open air, environmental conditions at these locations, O Recommends that members of the CEPT ad
6、here to the specifications for environmental conditions at weather-protected locations and in the open air contained in the annex of this Recommendation.” Edition of September 1, 1986 1 3 CEPT T/TR*OZ-b*E 232b4L4 0010525 B T/TR 02-06 E Page 3 Table of contents 1 . LOCATIONS AND EQUIPMENT CONCERNED 4
7、 2 . OBJECTIVES . 4 3 . DEFINITIONS 4 3.1. Open air 4 3.2. Weather-protected location 4 4 . SPECIFICATIONS . 4.1. Measurements of temperature and humidity 4.2. Climatic conditions for telecommunication equipment at weather-protected locations 4.3. Climatic conditions for telecommunication equipment
8、in the open air . 4.4. Biological conditions at weather-protected locations and in the open air 4.5. Chemically active substances at weather-protected locations and in the open air . . 4.6. Mechanically active substances at weather-protected locations and in the open air . 4.7. Mechanical conditions
9、 at weather-protected locations . 4.8. Mechanical conditions in the open air O . 4 . 4 5 . 7 . 9 . 9 . 10 . 11 . 11 CEPT T/TR*OZ-Ob*E m 232b414 001052b T m TITR 02-06 E Page 4 1. 2. 3. 3.1. 3.2. 4. 4.1. LOCATIONS AND EQUIPMENT CONCERNED The specifications apply to all equipment placed at weather-pro
10、tected locations usually without continuous- ly controlled climate and in the open air. This includes telecommunication centres without temperature and humidity controls. Other specifications (Recommendation T/TR 02-03) deal with environmental conditions and equipment in telecommunication centres wi
11、th temperature and humidity controls. Note: Conditions for equipment installed at subscribers premises are not dealt with in this Recommendation. Information on terminal equipment can be found in Recommendation T/CS 34-06. OBJECTIVES - To define climatograms for the different types of open-air clima
12、tes for the entire area of Europe. - To define the environmental conditions for equipment placed in the open air. - To define a limited number of climatograms for weather-protected locations, so that for each particular - To define the environmental conditions for equipment placed at weather-protect
13、ed locations. - To define the environmental conditions for transport and warehousing of the equipment concerned. -To define severities which will have a low probability of being exceeded. All specified values are maximum or limit values. These values may be reached but not occur permanently (I E C 7
14、21-3-3, 1). Note: The environmental classification for transport and warehousing will be defined at a late date in a single unified document. application a suitable one can be chosen by the user. DEFINITIONS Open air Open air is a location at which the equipment is not protected from direct weather
15、influences. It is often called a “not weather-protected location”. Weather-protected location A location at which the equipment is protected from direct weather influences. At an enclosed location direct weather influences should be excluded completely. At a sheltered location there may be additiona
16、l influences from wind-driven precipitation, dripping water, airborne contamination, etc. SPECIFICATIONS Measurements of temperature and humidity The air temperature and the humidity should not be measured near or above or inside technical equipment. The measuring points should be chosen such that t
17、he thermal effect of the equipment does not influence the result of the measurement. In the open air the temperature and humidity should be measured at 2 m above the ground. The temperature should be measured with equipment that absorbs a minimum of thermal radiation. The error of measurement should
18、 not exceed 0.5” K. The measurement error of relative humidity should not exceed f 5%. Edition of September 1, 1986 CEPT T/TR*02-0b*E 2326434 0030527 3.m T/TR 02-06 E Page 5 4.2. Climatic conditions for telecommunication equipment at weather-protected locations The climatic conditions at a weather-p
19、rotected location are affected by the open-air climate, the type of building construction and the type of climate controlling system (if any). To specify only one harmonized climatogram for such locations would lead in many cases to an overdesign of equipment. For this reason the climatograms in Fig
20、ures 1 (T/TR 02-06) to 4 (T/TR 02-06) are recom- mended, so that for each particular application the user can choose a suitable one. Within the limits of the climatograms the equipment must operate and it must meet the requirements laid down in specifications. There is, however, a small probability
21、of about 1 % that these limits will be exceeded. The behaviour of equipment when the limits are exceeded, as well as the specifications of more severe climatograms that are not exceeded (similar to those shown in Figures 5 (T/TR 02-06) to 9 (T/TR 02-06) with dotted lines), and the values of probabil
22、ity remain under study. The climatograms are valid for the whole area of Europe and up to an altitude of 2,000 m. The conditions described by the climatograms do not consider the effect of direct sun radiation and other parameters. Equipment dissipation has been taken into account but the user shoul
23、d consider the total heat load. This means that the administration or the end user is responsible for the limits of the climatogram not being exceeded because of equipment dissipation. To define the environmental conditions to which equipment is subjected, it is necessary to add the following inform
24、ation to that contained in the climato- grams : - Rate of change of temperature: 4.2.1. Additional conditions O 0.5“ C/min for the climatograms in Figures 1 (T/TR 02-06) and 2 (T/TR 02-06); 1 .O“ C/min for the climatograms in Figures 3 (T/TR 02-06) and 4 (T/TR 02-06). Note: The values have been aver
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTTR0206E1986ENVIRONMENTALCONDITIONSFORTELECOMMUNICATIONSEQUIPMENTATWEATHERPROTECTEDLOCATIONSEXCLUDINGTELECOMMUNICATIONCENTRESWITHTEMPERATUREANDHUMIDITYPDF

链接地址:http://www.mydoc123.com/p-593374.html