AWWA M11-2004 Steel Pipe - A Guide for Design and Installation (Fourth Edition Includes Errata 12 2013)《钢管设计和安装 第4版》.pdf
《AWWA M11-2004 Steel Pipe - A Guide for Design and Installation (Fourth Edition Includes Errata 12 2013)《钢管设计和安装 第4版》.pdf》由会员分享,可在线阅读,更多相关《AWWA M11-2004 Steel Pipe - A Guide for Design and Installation (Fourth Edition Includes Errata 12 2013)《钢管设计和安装 第4版》.pdf(259页珍藏版)》请在麦多课文档分享上搜索。
1、 Errata toAWWA Manual M11 Steel PipeA Guide for Design and Installation, 4th ed.(December 2013)Chapter 11. On page 1, paragraph 2, line 6 under History, the metric conversion should read 15,000 psi (103.42 MPa).2. On page 7, paragraph 2, lines 6 and 7 under Stress and Strain, “min” should read “in.”
2、3. On page 8, paragraph 2, lines 2 and 4, respectively, the metric conversions should read 30,000,000 psi (207 TPa) and 30 psi (207 kPa). 4. On page 10, paragraph 1, line 2, the metric conversion should read 30 psi (207 kPa). 5. On page 10, paragraph 1, line 4, “5,000 min/in.” should read “5,000 in.
3、/in.” 6. On page 10, paragraph 2, line 6, “5,000 min/in.” should read “5,000 in./in.” 7. On page 10, paragraph 2, line 8, “300,000 min/in.” should read “300,000 in./in.” 8. On page 11, paragraph 5, lines 6 and 10, under Analysis Based on Strain, “1,750 min/in.” should read “1,750 in./in.”9. On page
4、11, paragraph 7, line 2, under Analysis Based on Strain, “5,000 min/in.” should read “5,000 in./in.”10. On page 18, Eq 1-1 should read n= 2(cos2) + 1(sin2) (1-1)Chapter 611. On page 62, Table 6-1, column 1, Type of Soil, replace “Coarse-grained soils with little or no fines (SP, SM, GP, GW)” with “C
5、oarse-grained soils with little or no fines (SP, SW, GP, GW).”12. On page 67, line 5, replace (P = 0.7(4)(28,152) = 7,883 kg/m2) with (P = 0.07(4)(28,152) = 7,883 kg/m2).Chapter 6 (continued)13. On page 67, line 12, replace Wc= (1,922 (2) + 13,180) 2r/1,000 = 34r with Wc= (1,922 (0.61) + 13,180) 2r/
6、1,000 = 28.7r.14. On page 67, line 18, replace “3 ft (0.914 mm) cover” with “3 ft (0.914 m) cover.”Chapter 715. On page 73, the example problem should read k = 0.02 0.00012(120 90) = 0.0164 Scs= 0.0164 40,000log e( 21) = 28,300 psi (0.3125)2 0.3125 Sls = 3,000 psi (7-5) Se= 1,000 28.32+ (3.02) (3.0
7、28.3)null= 29,900 psi 29,900 30,00016. On page 85, Table 7-2, for x = 0.05L, replace 0.0715(wL2/12) with 0.715(wL2/12).Chapter 917. On page 122, last line of paragraph 3 under Elbows and Miter End Cuts should read “the deflection per miter weld shall be limited to 30. The radius of the elbow shall b
8、e.”18. On page 133, first sentence of paragraph 3 should read “Usually the blowoff will be below ground.” Chapter 1319. On page 194, Calculation of Size, under Eq 13-5 the definition of should read = safe bearing capacity of the soil, lbf/ft2(N/m2)20. On page 200, Table 13-4, for 24-in. Pipe OD, 250
9、 psi, Tie Bolt Diameter, in., should read “1 .”21. On page 200, Table 13-4, line 2 of NOTE, replace “undo” with “undue.”22. On page 203, Table 13-5, for 1 -in. dia., replace “A“ metric with (222.25).23. On page 203, Table 13-5, for 1 -in. dia., replace “A“ metric with (273.05). 24. On page 205, Figu
10、re 13-20, Note 4, replace “The minimum wall thickness.” with “The minimum weld thickness.” Science and TechnologyAWWA unites the drinking water community by developing and distributing authoritative scientific and technologicalknowledge. Through its members, AWWA develops industry standards for prod
11、ucts and processes that advance publichealth and safety. AWWA also provides quality improvement programs for water and wastewater utilities.Steel PipeA Guide for Design and InstallationAWWA MANUAL M11Fourth EditionCopyright 2004 American Water Works Association. All Rights Reserved.MANUAL OF WATER S
12、UPPLY PRACTICESM11, Fourth EditionSteel PipeA Guide for Design and InstallationCopyright 1964, 1985, 1989, 2004 American Water Works AssociationAll rights reserved. No part of this publication may be reproduced or transmitted in any form or by anymeans, electronic or mechanical, including photocopy,
13、 recording, or any information or retrieval system,except in the form of brief excerpts or quotations for review purposes, without the written permissionof the publisher.Project Manager and Technical Editor: Melissa ChristensenCopy Editor: Mart KelleProduction Editor: Carol StearnsLibrary of Congres
14、s Cataloging-in-Publication DataSteel Pipe : A Guide for Design and Installation.- 4th ed.p. cm. - (AWWA manual ; M11)Includes bibliographical references and index.ISBN 1-58321-274-41. Water pipes-Design and construction-Handbooks, manuals, etc. 2. Pipe,Steel-Design and construction-Handbooks, manua
15、ls etc. I. American Water WorksAssociation. II. Series.TD491.A49 S74628.15-dc222004043748Printed in the United States of AmericaAmerican Water Works Association6666 West Quincy AvenueDenver, CO 80235-3098ISBN 1-58321-274-4Printed on recycled paperCopyright 2004 American Water Works Association. All
16、Rights Reserved.iiiContentsList of Figures, viiList of Tables, xiForeword, xiiiAcknowledgments, xvChapter 1 History, Uses, and Physical Characteristics of Steel Pipe . 1History, 1Uses, 2Chemistry, Casting, and Heat Treatment, 3Physical Characteristics, 6Ductility and Yield Strength, 6Stress and Stra
17、in, 7Strain in Design, 9Analysis Based on Strain, 11Ductility in Design, 12Effects of Cold Working on Strength and Ductility, 13Brittle Fracture Considerations in Structural Design, 13Good Practice, 17Evaluation of Stresses in Spiral-Welded Pipe, 18References, 18Chapter 2 Manufacture and Testing 21M
18、anufacture, 21Testing, 24References, 25Chapter 3 Hydraulics of Pipelines . 27Formulas, 27Calculations, 31Economical Diameter of Pipe, 42Distribution Systems, 43Air Entrainment and Release, 43Good Practice, 43References, 43Chapter 4 Determination of Pipe Wall Thickness . 45Internal Pressure, 45Allowa
19、ble Tension Stress in Steel, 46Corrosion Allowance, 48External Fluid PressureUniform and Radial, 48Minimum Wall Thickness, 50Good Practice, 50References, 50Copyright 2004 American Water Works Association. All Rights Reserved.ivChapter 5 Water Hammer and Pressure Surge . 51Basic Relationships, 51Chec
20、klist for Pumping Mains, 54General Studies for Water Hammer Control, 55Allowance for Water Hammer, 56Pressure Rise Calculations, 56References, 56Chapter 6 External Loads . 59Load Determination, 59Deflection Determination, 60Buckling, 63Extreme External Loading Conditions, 65Computer Programs, 68Refe
21、rences, 68Chapter 7 Supports for Pipe 69Saddle Supports, 69Pipe Deflection as Beam, 73Methods of Calculation, 75Gradient of Supported Pipelines to Prevent Pocketing, 76Span Lengths and Stresses, 76Ring Girders, 79Ring-Girder Construction for Low-Pressure Pipe, 100Installation of Ring Girder Spans, 1
22、01References, 109Chapter 8 Pipe Joints . 111Bell-and-Spigot Joint With Rubber Gasket, 111Welded Joints, 112Bolted Sleeve-Type Couplings, 113Flanges, 113Grooved-and-Shouldered Couplings, 115Expansion and ContractionGeneral, 116Ground Friction and Line Tension, 117Good Practice, 118References, 119Chap
23、ter 9 Fittings and Appurtenances 121Designation of Fittings, 121Elbows and Miter End Cuts, 122Reducers, 130Bolt Hole Position, 130Design of Wye Branches, Laterals, Tees, and Crosses, 130Testing of Fittings, 131Unbalanced Thrust Forces, 131Frictional Resistance Between Soil and Pipe, 131Anchor Rings,
24、 131Nozzle Outlets, 131Copyright 2004 American Water Works Association. All Rights Reserved.vConnection to Other Pipe Material, 132Flanged Connections, 132Valve Connections, 132Blowoff Connections, 132Manholes, 133Insulating Joints, 133Air-Release Valves and Air/Vacuum Valves, 133Casing Spacers, 134
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AWWAM112004STEELPIPEAGUIDEFORDESIGNANDINSTALLATIONFOURTHEDITIONINCLUDESERRATA122013 钢管 设计 安装 PDF

链接地址:http://www.mydoc123.com/p-542400.html