ASTM F2476-2013 Standard Test Method for the Determination of Carbon Dioxide Gas Transmission Rate &40 CO2TR&41 Through Barrier Materials Using An Infrared Detector《采用红外检测器测定阻隔材料二氧.pdf
《ASTM F2476-2013 Standard Test Method for the Determination of Carbon Dioxide Gas Transmission Rate &40 CO2TR&41 Through Barrier Materials Using An Infrared Detector《采用红外检测器测定阻隔材料二氧.pdf》由会员分享,可在线阅读,更多相关《ASTM F2476-2013 Standard Test Method for the Determination of Carbon Dioxide Gas Transmission Rate &40 CO2TR&41 Through Barrier Materials Using An Infrared Detector《采用红外检测器测定阻隔材料二氧.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2476 13Standard Test Method forthe Determination of Carbon Dioxide Gas Transmission Rate(CO2TR) Through Barrier Materials Using An InfraredDetector1This standard is issued under the fixed designation F2476; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This method covers a procedure for determination of thesteady-state
3、rate of transmission of carbon dioxide gas throughplastics in the form of film, sheeting, laminates, coextrusions,or plastic-coated papers or fabrics. It provides for the determi-nation of (1) carbon dioxide gas transmission rate (CO2TR),(2) the permeance of the film to carbon dioxide gas (PCO2),and
4、 (3) carbon dioxide permeability coefficient (P”CO2)inthecase of homogeneous materials.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
5、and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1898 Practice for Sampling of Plastics (Withdrawn 1998)3E177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study t
6、oDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 carbon dioxide permeability coeffcient (P”CO2)theproduct of the permeance and the thickness of film. Thepermeability is meaningful only for homogeneous materials, inwhich case it is a property characteristic of the bulk mat
7、erial.This quantity should not be used unless the relationshipbetween thickness and permeance has been verified on testsusing several different thicknesses of the material. The SI unitof carbon dioxide permeability is the mol/msPa. The testconditions (see 3.1.3) must be stated.3.1.2 carbon dioxide p
8、ermeance (PCO2) the ratio of theCO2TR to the difference between the partial pressure of CO2on the two sides of the film. The SI unit of permeance is themol/(m2sPa). The test conditions (see 3.1.3) must be stated.3.1.3 carbon dioxide transmission rate (CO2TR) Thequantity of carbon dioxide gas passing
9、 through a unit area ofthe parallel surfaces of a plastic film per unit time under theconditions of the test. The SI unit of transmission rate is themol/(m2s). The test conditions, including temperature andcarbon dioxide partial pressure on both sides of the film, mustbe stated.3.1.3.1 DiscussionA c
10、ommonly used metric unit ofCO2TR is the cc(STP)/(m2day) at one atmosphere drivingforce pressure differential where: 1 cc(STP) is 44.62 mol. 1atm is 0.1013 MPa. and one day is 86.4 x 103s. CO2TR in SIunits is obtained by multiplying the value in metric units by5.164 x 10-10or the value in inch-pound
11、units cm3(STP) / (100in.2 day) by 8.004 x 10-9.4. Summary of Test Method4.1 The carbon dioxide gas transmission rate is determinedafter the sample has equilibrated in a dry-test environment. Inthis context, a “dry” environment is considered to be one inwhich the relative humidity is less than 1 %.4.
12、2 The specimen is mounted as a sealed semi-barrierbetween two chambers at ambient atmospheric pressure. Onechamber is slowly purged by a stream of nitrogen and the otherchamber with carbon dioxide.As carbon dioxide gas permeatesthrough the film into the nitrogen carrier gas, it is transportedto an i
13、nfrared detector where an electrical output is producedwhose magnitude is proportional to the amount of CO2flowinginto the detector per unit of time.5. Significance and Use5.1 Carbon dioxide gas transmission rate (CO2TR) is animportant determinant of the packaging protection afforded by1This test me
14、thod is under jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.10 onPermeation.Current edition approved Dec. 15, 2013. Published February 2014. Originallyapproved in 2005. Last previous edition approved in 2005 as F2476-05. DOI:10.1
15、520/F2476-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical st
16、andard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1barrier materials. It is not, however, the sole determinant, andadditional tests, based on experience, must be used to correlatepackaging performance
17、with CO2TR. It is suitable as a refereemethod of testing, provided that purchaser and seller haveagreed on sampling procedures, standardization procedures,test conditions and acceptance criteria.6. Apparatus6.1 Carbon Dioxide Gas Transmission Apparatus, as dia-grammed in Fig. 1 or Fig. 2, with the f
18、ollowing:6.1.1 Diffusion Cellshall consist of two metal halves,which, when closed upon the test specimen, will accuratelydefine a circular area. A typical acceptable diffusion cell area is50 cm2. The volume enclosed by each cell half, when clamped,in not critical: it should be small enough to allow
19、for rapid gasexchange, but not so small that an unsupported film thathappens to sag or bulge will contact the top or bottom of thecell.6.1.1.1 O-Ring Groovean appropriately sized groove, ma-chined into the CO2(or test gas) side of the diffusion cell,retains an elastomer O-ring. The test area is cons
20、idered to bethat area established by the inside contact diameter of thecompressed O-ring when the diffusion cell is clamped shutagainst the test specimen. The area, A, can be obtained bymeasuring the inside diameter of the imprint left by the O-ringon the specimen after it has been removed from the
21、diffusioncell.6.1.1.2 The nitrogen (or carrier gas) side of the diffusion cellshall have a flat raised rim. Since this rim is a critical sealingsurface against which the test specimen is pressed, it shall besmooth and flat, without radial scratches.6.1.1.3 Diffusion Cell Pneumatic Fittingseach half
22、of thediffusion cell shall incorporate suitable fittings for the intro-duction and exhaust of gases without significant loss orleakage.6.1.1.4 It is desirable to thermostatically control the diffu-sion cell. Because the transmission rate is a function oftemperature, it shall be controlled to within
23、6 0.1C.6.1.1.5 Experience has shown that arrangements using mul-tiple diffusion cells are a practical way to increase the numberof measurements that can be obtained from an infrared sensor.A valving manifold connects the carrier gas side of eachindividual diffusion cell to the sensor in a predetermi
24、nedpattern. Carrier gas is continually purging the carrier gas sideof those cells that are not connected to the sensor. Either testgas or carrier gas, as is appropriate, purges the test gas chamberof any individual cell.6.1.2 Flowmetera means shall be provided to establishand maintain test gas and c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF24762013STANDARDTESTMETHODFORTHEDETERMINATIONOFCARBONDIOXIDEGASTRANSMISSIONRATE40CO2TR41THROUGHBARRIERMATERIALSUSINGANINFRAREDDETECTOR

链接地址:http://www.mydoc123.com/p-538809.html